These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
324 related articles for article (PubMed ID: 19303370)
1. Inappropriate implantable cardioverter-defibrillator therapy during exercise: what is the mechanism? Vollmann D; Lüthje L; Zabel M Heart Rhythm; 2009 May; 6(5):718-9. PubMed ID: 19303370 [No Abstract] [Full Text] [Related]
2. Multiple appropriate and spurious defibrillator shocks in a patient with right ventricular cardiomyopathy. Strohmer B; Schernthaner C; Pichler M Int J Cardiol; 2005 Jul; 102(2):363-6. PubMed ID: 15982515 [TBL] [Abstract][Full Text] [Related]
3. Multiple ICD shocks in a patient with dilated cardiomyopathy: What is the mechanism? Fontenla A; López-Gil M; Rodríguez Muñoz D; Díez de Las Heras D; Arribas F J Cardiovasc Electrophysiol; 2019 May; 30(5):781-784. PubMed ID: 30688386 [TBL] [Abstract][Full Text] [Related]
4. Ventricular tachycardia initiated by high energy cardioversion in a patient with an implantable cardioverter defibrillator. Chinushi M; Aizawa Y; Higuchi K Heart; 1997 Apr; 77(4):373-4. PubMed ID: 9155621 [TBL] [Abstract][Full Text] [Related]
5. Electrical storm in a patient with dilated non-ischaemic cardiomyopathy. De Meyer G; Van Beeumen K; Duytschaever M Acta Cardiol; 2009 Oct; 64(5):681-5. PubMed ID: 20058518 [TBL] [Abstract][Full Text] [Related]
6. [Inappropriate therapy of an implantable cardioverter-defibrillator--is it always an undesired event? A case report]. Krzyzanowski K; Michałkiewicz D; Wierzbowski R; Gniłka A; Ryczek R; Orski Z; Kubik L Kardiol Pol; 2009 Aug; 67(8):927-9. PubMed ID: 19784895 [TBL] [Abstract][Full Text] [Related]
7. External implantable defibrillator as a bridge to reimplant after implantable cardioverter-defibrillator explant. Dell'Era G; Magnani A; Occhetta E Europace; 2015 Nov; 17(11):1726. PubMed ID: 26462698 [No Abstract] [Full Text] [Related]
8. [Inappropriate therapy of an implantable cardioverter-defibrillator--is it always an undesired event?]. Oreziak A; Przybylski A Kardiol Pol; 2009 Aug; 67(8):930-1. PubMed ID: 19885986 [No Abstract] [Full Text] [Related]
9. Death due to an implantable cardioverter defibrillator. Messali A; Thomas O; Chauvin M; Coumel P; Leenhardt A J Cardiovasc Electrophysiol; 2004 Aug; 15(8):953-6. PubMed ID: 15333095 [TBL] [Abstract][Full Text] [Related]
10. Multiple shocks after upgrade of an implantable cardioverter-defibrillator to a cardiac resynchronization therapy-defibrillator device. Francisco GM; Sharma S; Dougherty AH; Kantharia BK Cardiol J; 2009; 16(5):473-6. PubMed ID: 19753529 [TBL] [Abstract][Full Text] [Related]
11. Inappropriate shock for myopotential over-sensing in a patient with subcutaneous ICD. Corzani A; Ziacchi M; Biffi M; Diemberger I; Martignani C; Boriani G Indian Heart J; 2015; 67(1):56-9. PubMed ID: 25820052 [TBL] [Abstract][Full Text] [Related]
12. J Waves Are Associated With the Increased Occurrence of Life-Threatening Ventricular Tachyarrhythmia in Patients With Nonischemic Cardiomyopathy. Naruse Y; Nogami A; Shinoda Y; Hanaki Y; Shirai Y; Kowase S; Kurosaki K; Machino T; Kuroki K; Yamasaki H; Igarashi M; Sekiguchi Y; Aonuma K J Cardiovasc Electrophysiol; 2016 Dec; 27(12):1448-1453. PubMed ID: 27593399 [TBL] [Abstract][Full Text] [Related]
13. Antitachycardia pacing therapy for the successful treatment of lead fracture. Bhimani AA; Deeprasertkul P; Nannapaneni N; Carayannopoulos GN J Cardiovasc Electrophysiol; 2015 Feb; 26(2):228-9. PubMed ID: 25354719 [No Abstract] [Full Text] [Related]
14. Man With Hypertension and Heart Failure. Mohebbi MR; Katta N; Shea CM; Shea MM Ann Emerg Med; 2017 Jul; 70(1):46-48. PubMed ID: 28645412 [No Abstract] [Full Text] [Related]
15. Inappropriate shock delivery by implantable cardioverter defibrillator due to electrical leak from bathroom tap. Camsarı A; Yılmaz DC; Ozcan T Clin Res Cardiol; 2010 Nov; 99(11):761-3. PubMed ID: 20683725 [No Abstract] [Full Text] [Related]
16. Atrial fibrillation in patients with implantable defibrillators. Sakhuja R; Shah AJ; Keebler M; Thakur RK Cardiol Clin; 2009 Feb; 27(1):151-61, ix-x. PubMed ID: 19111771 [TBL] [Abstract][Full Text] [Related]
17. Shocking truths about implantable cardioverter defibrillator monitoring zones. Mansour F; Thibault B; Dubuc M; Guerra PG; Macle L; Brugada R; Roy D; Talajic M; Khairy P Pacing Clin Electrophysiol; 2007 Sep; 30(9):1146-8. PubMed ID: 17725760 [TBL] [Abstract][Full Text] [Related]
18. Inappropriate implantable cardioverter-defibrillator therapy: many causes and many possible solutions. Zareba W Cardiol J; 2009; 16(5):391-3. PubMed ID: 19753515 [No Abstract] [Full Text] [Related]
19. Apparent inappropriate shocks from an implantable cardioverter defibrillator: Moore DR; Kok LC; Vijayaraman P J Cardiovasc Electrophysiol; 2004 Jan; 15(1):116-7. PubMed ID: 15028086 [No Abstract] [Full Text] [Related]
20. Supraventricular tachycardia vs ventricular tachycardia: what is the rhythm? Al-Ahmad A; Tsiperfal A; Hsia HH; Wang PJ Heart Rhythm; 2006 Apr; 3(4):490-1. PubMed ID: 16567303 [No Abstract] [Full Text] [Related] [Next] [New Search]