218 related articles for article (PubMed ID: 19304770)
1. Validation of a Monte Carlo efficiency calibration procedure for a partial body counter system with a voxel model of the LLNL torso phantom.
Hegenbart L; Marzocchi O; Breustedt B; Urban M
Radiat Prot Dosimetry; 2009 Feb; 133(3):158-64. PubMed ID: 19304770
[TBL] [Abstract][Full Text] [Related]
2. Application of voxel phantoms and Monte Carlo method to whole-body counter calibration.
Kinase S; Takagi S; Noguchi H; Saito K
Radiat Prot Dosimetry; 2007; 125(1-4):189-93. PubMed ID: 17522042
[TBL] [Abstract][Full Text] [Related]
3. Application of Monte Carlo calculation and OEDIPE software for virtual calibration of an in vivo counting system.
Liye L; Franck D; de Carlan L; Junli L
Radiat Prot Dosimetry; 2007; 127(1-4):282-6. PubMed ID: 18077473
[TBL] [Abstract][Full Text] [Related]
4. The LLNL voxel phantom: comparison with the physical phantom and previous virtual phantoms.
Kramer GH; Capello K; Sung J
Health Phys; 2007 Dec; 93(6):696-700. PubMed ID: 17993850
[TBL] [Abstract][Full Text] [Related]
5. Use of photographic images to construct voxel phantoms for use in whole-body counting.
Kim JS; Ha WH; Jeong JH; Cho KW; Lee JK
Radiat Prot Dosimetry; 2010 Feb; 138(2):119-22. PubMed ID: 19951986
[TBL] [Abstract][Full Text] [Related]
6. The standfast whole body counter and the sliced BOMAB phantom: efficiency as a function of number of sources and energy modeled by MCNP5.
Kramer GH; Capello K
Health Phys; 2007 Feb; 92(2):170-5. PubMed ID: 17220718
[TBL] [Abstract][Full Text] [Related]
7. Voxel phantoms: NORMAN vs. VIP-Man, what differences are there?
Kramer GH; Capello K; Cardenas-Mendez E
Health Phys; 2009 Feb; 96(2 Suppl):S22-6. PubMed ID: 19125052
[TBL] [Abstract][Full Text] [Related]
8. A specific voxel phantom for in vivo measurements of 241Am in the knee.
Moraleda M; Lis M; Gómez-Ros JM; López MA
Radiat Prot Dosimetry; 2007; 127(1-4):258-61. PubMed ID: 17553865
[TBL] [Abstract][Full Text] [Related]
9. HML's whole body counter: measuring highly radioactive persons.
Kramer GH; Capello K; Chiang A; Hauck BM
Health Phys; 2009 Dec; 97(6):630-6. PubMed ID: 19901599
[TBL] [Abstract][Full Text] [Related]
10. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.
DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF
Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525
[TBL] [Abstract][Full Text] [Related]
11. Evaluation of counting efficiencies of a whole-body counter using Monte Carlo simulation with voxel phantoms.
Takahashi M; Kinase S; Kramer R
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):407-10. PubMed ID: 21131662
[TBL] [Abstract][Full Text] [Related]
12. Whole body counter calibration using Monte Carlo modeling with an array of phantom sizes based on national anthropometric reference data.
Shypailo RJ; Ellis KJ
Phys Med Biol; 2011 May; 56(10):2979-97. PubMed ID: 21490381
[TBL] [Abstract][Full Text] [Related]
13. Uncertainty budget for a whole body counter in the scan geometry and computer simulation of the calibration phantoms.
Schlagbauer M; Hrnecek E; Rollet S; Fischer H; Brandl A; Kindl P
Radiat Prot Dosimetry; 2007; 125(1-4):149-52. PubMed ID: 17656442
[TBL] [Abstract][Full Text] [Related]
14. Application of voxel phantoms in whole-body counting for the validation of calibration phantoms and the assessment of uncertainties.
de Carlan L; Roch P; Blanchardon E; Franck D
Radiat Prot Dosimetry; 2007; 125(1-4):477-82. PubMed ID: 17018545
[TBL] [Abstract][Full Text] [Related]
15. Effect of mass, at a fixed height, on the counting efficiency of a BOMAB phantom in three types of whole body counter modeled by MCNP5.
Kramer GH; Capello K; Phan Q
Health Phys; 2008 Aug; 95(2):234-40. PubMed ID: 18617805
[TBL] [Abstract][Full Text] [Related]
16. Monte Carlo simulation of the movement and detection efficiency of a whole-body counting system using a BOMAB phantom.
Bento J; Barros S; Teles P; Neves M; Gonçalves I; Corisco J; Vaz P
Radiat Prot Dosimetry; 2012 Mar; 148(4):403-13. PubMed ID: 21525044
[TBL] [Abstract][Full Text] [Related]
17. Performance characteristics of a commercially available whole body counting phantom measured experimentally and using Monte Carlo simulations.
Kramer GH; Hauck BM; Capello K
Health Phys; 2005 Apr; 88(4):350-6. PubMed ID: 15761296
[TBL] [Abstract][Full Text] [Related]
18. Efficiency calibration of a whole-body-counting measurement setup using a modular physical phantom.
Lebacq AL; Bruggeman M; Vanhavere F
Radiat Prot Dosimetry; 2011 Mar; 144(1-4):411-4. PubMed ID: 21216733
[TBL] [Abstract][Full Text] [Related]
19. An analysis of dependency of counting efficiency on worker anatomy for in vivo measurements: whole-body counting.
Zhang B; Mille M; Xu XG
Phys Med Biol; 2008 Jul; 53(13):3463-75. PubMed ID: 18547914
[TBL] [Abstract][Full Text] [Related]
20. Development of an integrated couple of anthropomorphic models for dosimetric studies.
Ferrari P
Radiat Prot Dosimetry; 2010 Dec; 142(2-4):191-200. PubMed ID: 20696671
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]