136 related articles for article (PubMed ID: 19308901)
1. [Spectrum and bleeding complications of sonographically guided interventions of the liver and pancreas].
Frieser M; Lindner A; Meyer S; Westerteicher M; Hänsler J; Haendl T; Hahn EG; Strobel D; Bernatik T
Ultraschall Med; 2009 Apr; 30(2):168-74. PubMed ID: 19308901
[TBL] [Abstract][Full Text] [Related]
2. Postinterventional pain and complications of sonographically guided interventions in the liver and pancreas.
Lindner A; Frieser M; Heide R; Wildner D; Neurath MF; Dauth W; Bernatik T; Strobel D
Ultraschall Med; 2014 Apr; 35(2):159-65. PubMed ID: 23354721
[TBL] [Abstract][Full Text] [Related]
3. Incidence of bleeding in 8172 percutaneous ultrasound-guided intraabdominal diagnostic and therapeutic interventions - results of the prospective multicenter DEGUM interventional ultrasound study (PIUS study).
Strobel D; Bernatik T; Blank W; Will U; Reichel A; Wüstner M; Keim V; Schacherer D; Barreiros AP; Kunze G; Nürnberg D; Ignee A; Burmester E; Bunk AA; Friedrich-Rust M; Froehlich E; Schuler A; Jenssen C; Bohle W; Mauch M; Dirks K; Kaemmer J; Pachmann C; Stock J; Hocke M; Kendel A; Schmidt C; Jakobeit C; Kinkel H; Heinz W; Hübner G; Pichler M; Müller T
Ultraschall Med; 2015 Apr; 36(2):122-31. PubMed ID: 25876060
[TBL] [Abstract][Full Text] [Related]
4. Percutaneous ultrasonographically guided liver punctures: an analysis of 1961 patients over a period of ten years.
Mueller M; Kratzer W; Oeztuerk S; Wilhelm M; Mason RA; Mao R; Haenle MM
BMC Gastroenterol; 2012 Dec; 12():173. PubMed ID: 23216751
[TBL] [Abstract][Full Text] [Related]
5. Prospective comparative study of the EUS guided 25-gauge FNA needle with the 19-gauge Trucut needle and 22-gauge FNA needle in patients with solid pancreatic masses.
Sakamoto H; Kitano M; Komaki T; Noda K; Chikugo T; Dote K; Takeyama Y; Das K; Yamao K; Kudo M
J Gastroenterol Hepatol; 2009 Mar; 24(3):384-90. PubMed ID: 19032453
[TBL] [Abstract][Full Text] [Related]
6. Complications after interventional sonography of focal liver lesions: a 22-year single-center experience.
Giorgio A; Tarantino L; de Stefano G; Francica G; Esposito F; Perrotta A; Aloisio V; Farella N; Mariniello N; Coppola C; Caturelli E
J Ultrasound Med; 2003 Feb; 22(2):193-205. PubMed ID: 12562124
[TBL] [Abstract][Full Text] [Related]
7. Correlation between coagulation profile findings and bleeding complications after ultrasound-guided biopsies: 434 cases (1993-1996).
Bigge LA; Brown DJ; Penninck DG
J Am Anim Hosp Assoc; 2001; 37(3):228-33. PubMed ID: 11361113
[TBL] [Abstract][Full Text] [Related]
8. Image-guided percutaneous splenic interventions.
Singh AK; Shankar S; Gervais DA; Hahn PF; Mueller PR
Radiographics; 2012; 32(2):523-34. PubMed ID: 22411947
[TBL] [Abstract][Full Text] [Related]
9. Retrospective analysis of the utility of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in pancreatic masses, using a 22-gauge or 25-gauge needle system: a multicenter experience.
Yusuf TE; Ho S; Pavey DA; Michael H; Gress FG
Endoscopy; 2009 May; 41(5):445-8. PubMed ID: 19418399
[TBL] [Abstract][Full Text] [Related]
10. [Endoscopic ultrasound-guided biopsy: diagnostic yield, pitfalls, quality management].
Jenssen C; Möller K; Wagner S; Sarbia M
Z Gastroenterol; 2008 Sep; 46(9):897-908. PubMed ID: 18810676
[TBL] [Abstract][Full Text] [Related]
11. Ultrasound-guided radiofrequency ablation (RFA) for inoperable gastrointestinal liver metastases.
Hofer S; Oberholzer C; Beck S; Looser C; Ludwig C
Ultraschall Med; 2008 Aug; 29(4):388-92. PubMed ID: 18785319
[TBL] [Abstract][Full Text] [Related]
12. [Ultrasound guided fine- and coarse-needle puncture of the abdominal and retroperitoneal space].
Binder T; Swobodnik W; Wechsler JG; Löschinger K; Eckert E; Schoengen A; Heimpel H; Ditschuneit H
Dtsch Med Wochenschr; 1987 Jan; 113(2):43-8. PubMed ID: 3322762
[TBL] [Abstract][Full Text] [Related]
13. Predictors of bleeding complications following percutaneous image-guided liver biopsy: a scoping review.
Midia M; Odedra D; Shuster A; Midia R; Muir J
Diagn Interv Radiol; 2019 Jan; 25(1):71-80. PubMed ID: 30644369
[TBL] [Abstract][Full Text] [Related]
14. Fine-needle liver biopsy in patients with severely impaired coagulation.
Caturelli E; Squillante MM; Andriulli A; Siena DA; Cellerino C; De Luca F; Marzano MA; Pompili M; Rapaccini GL
Liver; 1993 Oct; 13(5):270-3. PubMed ID: 8259040
[TBL] [Abstract][Full Text] [Related]
15. Ultrasonically guided fine needle aspiration biopsy of hepatic and pancreatic space-occupying lesions and percutaneous abscess drainage.
Braun B; Dormeyer HH
Klin Wochenschr; 1981 Jun; 59(12):707-12. PubMed ID: 7253544
[TBL] [Abstract][Full Text] [Related]
16. Is ultrasound-guided fine-needle biopsy effective for diagnosis of early HCC in liver cirrhosis?
Schölmerich J
Nat Clin Pract Gastroenterol Hepatol; 2005 Jan; 2(1):16-7. PubMed ID: 16265093
[No Abstract] [Full Text] [Related]
17. Ultrasound-guided fine needle biopsy of pancreatic masses: results of a multicenter study.
Di Stasi M; Lencioni R; Solmi L; Magnolfi F; Caturelli E; De Sio I; Salmi A; Buscarini L
Am J Gastroenterol; 1998 Aug; 93(8):1329-33. PubMed ID: 9707060
[TBL] [Abstract][Full Text] [Related]
18. Endoscopic ultrasound guided radiofrequency ablation in pancreas.
Seicean A; Tefas C; Ungureanu B; Săftoiu A
Hepatogastroenterology; 2014 Sep; 61(134):1717-21. PubMed ID: 25436368
[TBL] [Abstract][Full Text] [Related]
19. [Echo-guided radiofrequency percutaneous ablation of hepatocellular carcinoma in cirrhosis using a cooled needle].
Marone G; Francica G; D'Angelo V; Iodice G; Pastore P; Altamura G; Cusati B; Siani A
Radiol Med; 1998 Jun; 95(6):624-9. PubMed ID: 9717546
[TBL] [Abstract][Full Text] [Related]
20. Prospective study of the incidence of ultrasound-detected hepatic hematomas due to percutaneous Menghini needle liver biopsy and laparoscopy-guided Silverman needle biopsy.
Glaser J; Mann O; Siegmüller M; Pausch J
Ital J Gastroenterol; 1994 Sep; 26(7):338-41. PubMed ID: 7812026
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]