These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

174 related articles for article (PubMed ID: 19317584)

  • 1. Endovascular device design in the future: transformation from trial and error to computational design.
    Zarins CK; Taylor CA
    J Endovasc Ther; 2009 Feb; 16 Suppl 1():I12-21. PubMed ID: 19317584
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Cardiovascular stent design and vessel stresses: a finite element analysis.
    Lally C; Dolan F; Prendergast PJ
    J Biomech; 2005 Aug; 38(8):1574-81. PubMed ID: 15958213
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Finite element analysis and stent design: Reduction of dogboning.
    De Beule M; Van Impe R; Verhegghe B; Segers P; Verdonck P
    Technol Health Care; 2006; 14(4-5):233-41. PubMed ID: 17065746
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Realistic finite element-based stent design: the impact of balloon folding.
    De Beule M; Mortier P; Carlier SG; Verhegghe B; Van Impe R; Verdonck P
    J Biomech; 2008; 41(2):383-9. PubMed ID: 17920068
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of element technologies for modeling stent expansion.
    Hall GJ; Kasper EP
    J Biomech Eng; 2006 Oct; 128(5):751-6. PubMed ID: 16995762
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Finite element analysis of covered microstents.
    Gu L; Santra S; Mericle RA; Kumar AV
    J Biomech; 2005 Jun; 38(6):1221-7. PubMed ID: 15863106
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Modeling of size dependent failure in cardiovascular stent struts under tension and bending.
    Harewood FJ; McHugh PE
    Ann Biomed Eng; 2007 Sep; 35(9):1539-53. PubMed ID: 17503185
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stainless and shape memory alloy coronary stents: a computational study on the interaction with the vascular wall.
    Migliavacca F; Petrini L; Massarotti P; Schievano S; Auricchio F; Dubini G
    Biomech Model Mechanobiol; 2004 Jun; 2(4):205-17. PubMed ID: 15029511
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 50 Hz fatigue testing of large diameter stent grafts.
    Schröder B; Kaufmann R
    Med Device Technol; 2007; 18(2):58-60. PubMed ID: 17494505
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computational fluid dynamics investigation of a centrifugal blood pump.
    Legendre D; Antunes P; Bock E; Andrade A; Biscegli JF; Ortiz JP
    Artif Organs; 2008 Apr; 32(4):342-8. PubMed ID: 18370951
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modeling of antegrade and retrograde flow into a branch artery of the aorta: implications for endovascular stent-grafting and extra-anatomical visceral bypass.
    Sutalo ID; Lawrence-Brown MM; Ahmed S; Liffman K; Semmens JB
    J Endovasc Ther; 2008 Jun; 15(3):300-9. PubMed ID: 18540695
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Shear-slip Mesh Update Method: implementation and applications.
    Behr M; Arora D
    Comput Methods Biomech Biomed Engin; 2003 Apr; 6(2):113-23. PubMed ID: 12745425
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Computational and functional evaluation of a microfluidic blood flow device.
    Gilbert RJ; Park H; Rasponi M; Redaelli A; Gellman B; Dasse KA; Thorsen T
    ASAIO J; 2007; 53(4):447-55. PubMed ID: 17667229
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design of a pseudo-physiological test bench specific to the development of biodegradable metallic biomaterials.
    Lévesque J; Hermawan H; Dubé D; Mantovani D
    Acta Biomater; 2008 Mar; 4(2):284-95. PubMed ID: 18033745
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fatigue and life prediction for cobalt-chromium stents: A fracture mechanics analysis.
    Marrey RV; Burgermeister R; Grishaber RB; Ritchie RO
    Biomaterials; 2006 Mar; 27(9):1988-2000. PubMed ID: 16260033
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evolution and future of preclinical testing for endovascular grafts.
    Abel DB; Dehdashtian MM; Rodger ST; Smith AC; Smith LJ; Waninger MS
    J Endovasc Ther; 2006 Oct; 13(5):649-59. PubMed ID: 17042666
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Innovative technologies for the assessment of cardiovascular medical devices: state-of-the-art techniques for artificial heart valve testing.
    Grigioni M; Daniele C; D'Avenio G; Morbiducci U; Del Gaudio C; Abbate M; Di Meo D
    Expert Rev Med Devices; 2004 Sep; 1(1):81-93. PubMed ID: 16293012
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluating the in situ loading and accelerated durability of barbs located on bifurcated aorto-iliac stent-grafts.
    Conti JC; Strope ER
    Biomed Sci Instrum; 2000; 36():93-8. PubMed ID: 10834215
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Finite element method and computational fluid dynamics used in the analysis of a stent].
    Liang D; Yang D; Qi M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2007 Jun; 24(3):549-53. PubMed ID: 17713259
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro measurement and calculation of drag force on iliac limb stentgraft in a compliant arterial wall model.
    Sinha Roy A; Westt K; Rontala RS; Greenberg RK; Banerjee RK
    Mol Cell Biomech; 2007 Dec; 4(4):211-26. PubMed ID: 18437918
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.