BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

344 related articles for article (PubMed ID: 19318027)

  • 1. Canadian Laboratory Initiative on Pediatric Reference Interval Database (CALIPER): pediatric reference intervals for an integrated clinical chemistry and immunoassay analyzer, Abbott ARCHITECT ci8200.
    Chan MK; Seiden-Long I; Aytekin M; Quinn F; Ravalico T; Ambruster D; Adeli K
    Clin Biochem; 2009 Jun; 42(9):885-91. PubMed ID: 19318027
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pediatric reference intervals for lipids and apolipoproteins on the VITROS 5,1 FS Chemistry System.
    Yip PM; Chan MK; Nelken J; Lepage N; Brotea G; Adeli K
    Clin Biochem; 2006 Oct; 39(10):978-83. PubMed ID: 16962571
    [TBL] [Abstract][Full Text] [Related]  

  • 3. CLSI-based transference of the CALIPER database of pediatric reference intervals to Beckman Coulter DxC biochemical assays.
    Araújo PA; Thomas D; Sadeghieh T; Bevilacqua V; Chan MK; Chen Y; Randell E; Adeli K
    Clin Biochem; 2015 Sep; 48(13-14):870-80. PubMed ID: 26070714
    [TBL] [Abstract][Full Text] [Related]  

  • 4. CLSI-based transference of the CALIPER database of pediatric reference intervals from Abbott to Beckman, Ortho, Roche and Siemens Clinical Chemistry Assays: direct validation using reference samples from the CALIPER cohort.
    Estey MP; Cohen AH; Colantonio DA; Chan MK; Marvasti TB; Randell E; Delvin E; Cousineau J; Grey V; Greenway D; Meng QH; Jung B; Bhuiyan J; Seccombe D; Adeli K
    Clin Biochem; 2013 Sep; 46(13-14):1197-219. PubMed ID: 23578738
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Pediatric reference intervals for 28 chemistries and immunoassays on the Roche cobas 6000 analyzer--a CALIPER pilot study.
    Kulasingam V; Jung BP; Blasutig IM; Baradaran S; Chan MK; Aytekin M; Colantonio DA; Adeli K
    Clin Biochem; 2010 Sep; 43(13-14):1045-50. PubMed ID: 20501329
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Pediatric reference value distributions for vitamins A and E in the CALIPER cohort and establishment of age-stratified reference intervals.
    Raizman JE; Cohen AH; Teodoro-Morrison T; Wan B; Khun-Chen M; Wilkenson C; Bevilaqua V; Adeli K
    Clin Biochem; 2014 Jun; 47(9):812-5. PubMed ID: 24726493
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of analytical methods and workflow performance of the Architect ci8200 integrated serum/plasma analyzer system.
    Hubl W; Zogbaum M; Boyd JC; Savory J; Schubert M; Meyer D; Demant T
    Clin Chim Acta; 2005 Jul; 357(1):43-54. PubMed ID: 15963793
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Thyroid hormone reference intervals in an ambulatory Arab population on the Abbott Architect i2000 immunoassay analyzer.
    Dhatt GS; Griffin G; Agarwal MM
    Clin Chim Acta; 2006 Feb; 364(1-2):226-9. PubMed ID: 16098499
    [TBL] [Abstract][Full Text] [Related]  

  • 9. CLSI-based transference and verification of CALIPER pediatric reference intervals for 29 Ortho VITROS 5600 chemistry assays.
    Higgins V; Truong D; Woroch A; Chan MK; Tahmasebi H; Adeli K
    Clin Biochem; 2018 Mar; 53():93-103. PubMed ID: 29307782
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Transference of CALIPER pediatric reference intervals to biochemical assays on the Roche cobas 6000 and the Roche Modular P.
    Higgins V; Chan MK; Nieuwesteeg M; Hoffman BR; Bromberg IL; Gornall D; Randell E; Adeli K
    Clin Biochem; 2016 Jan; 49(1-2):139-49. PubMed ID: 26297116
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Complex reference value distributions and partitioned reference intervals across the pediatric age range for 14 specialized biochemical markers in the CALIPER cohort of healthy community children and adolescents.
    Kelly J; Raizman JE; Bevilacqua V; Chan MK; Chen Y; Quinn F; Shodin B; Armbruster D; Adeli K
    Clin Chim Acta; 2015 Oct; 450():196-202. PubMed ID: 26310965
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Pediatric reference value distributions and covariate-stratified reference intervals for 29 endocrine and special chemistry biomarkers on the Beckman Coulter Immunoassay Systems: a CALIPER study of healthy community children.
    Karbasy K; Lin DC; Stoianov A; Chan MK; Bevilacqua V; Chen Y; Adeli K
    Clin Chem Lab Med; 2016 Apr; 54(4):643-57. PubMed ID: 26457782
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Population-based pediatric reference intervals for general clinical chemistry analytes on the Abbott Architect ci8200 instrument.
    Ridefelt P; Aldrimer M; Rödöö PO; Niklasson F; Jansson L; Gustafsson J; Hellberg D
    Clin Chem Lab Med; 2012 Feb; 50(5):845-51. PubMed ID: 22628328
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of immunoturbidimetric specific protein methods using the Architect ci8200: comparison with immunonephelometry.
    Denham E; Mohn B; Tucker L; Lun A; Cleave P; Boswell DR
    Ann Clin Biochem; 2007 Nov; 44(Pt 6):529-36. PubMed ID: 17961307
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Marked biological variance in endocrine and biochemical markers in childhood: establishment of pediatric reference intervals using healthy community children from the CALIPER cohort.
    Bailey D; Colantonio D; Kyriakopoulou L; Cohen AH; Chan MK; Armbruster D; Adeli K
    Clin Chem; 2013 Sep; 59(9):1393-405. PubMed ID: 23637247
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reference intervals on the Abbot Architect for serum thyroid hormones, lipids and prolactin in healthy children in a population-based study.
    Aldrimer M; Ridefelt P; Rödöö P; Niklasson F; Gustafsson J; Hellberg D
    Scand J Clin Lab Invest; 2012 Jul; 72(4):326-32. PubMed ID: 22724627
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pediatric reference intervals for 29 Ortho VITROS 5600 immunoassays using the CALIPER cohort of healthy children and adolescents.
    Higgins V; Fung AWS; Chan MK; Macri J; Adeli K
    Clin Chem Lab Med; 2018 Jan; 56(2):327-340. PubMed ID: 28723610
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Closing the gaps in pediatric laboratory reference intervals: a CALIPER database of 40 biochemical markers in a healthy and multiethnic population of children.
    Colantonio DA; Kyriakopoulou L; Chan MK; Daly CH; Brinc D; Venner AA; Pasic MD; Armbruster D; Adeli K
    Clin Chem; 2012 May; 58(5):854-68. PubMed ID: 22371482
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Establishing and evaluating pediatric thyroid reference intervals on the Roche Modular Analytics E 170 using computational statistics and data-mining techniques.
    Henderson MP; Grey V
    Clin Biochem; 2011 Jul; 44(10-11):767-70. PubMed ID: 21620814
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pediatric reference intervals determined in ambulatory and hospitalized children and juveniles.
    Heiduk M; Päge I; Kliem C; Abicht K; Klein G
    Clin Chim Acta; 2009 Aug; 406(1-2):156-61. PubMed ID: 19549511
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.