These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 19324358)

  • 1. Correcting rotational deformity following femoral nailing.
    Piper K; Chia M; Graham E
    Injury; 2009 Jun; 40(6):660-2. PubMed ID: 19324358
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Femoral fracture malrotation caused by freehand versus navigated distal interlocking.
    Gardner MJ; Citak M; Kendoff D; Krettek C; Hüfner T
    Injury; 2008 Feb; 39(2):176-80. PubMed ID: 17888433
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rotational stability of femoral osteosynthesis in femoral fractures - navigated measurements.
    Citak M; Kendoff D; Gardner MJ; Oszwald M; O'Loughlin PF; Olivier LC; Krettek C; Hüfner T; Citak M
    Technol Health Care; 2009; 17(1):25-32. PubMed ID: 19478402
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Increasing nail-cortical contact to increase fixation stability and decrease implant strain in antegrade locked nailing of distal femoral fractures: a biomechanical study.
    Huang SC; Lin CC; Lin J
    J Trauma; 2009 Feb; 66(2):436-42. PubMed ID: 19065112
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Stress analysis of the distal locking screws for femoral interlocking nailing.
    Lin J; Lin SJ; Chen PQ; Yang SH
    J Orthop Res; 2001 Jan; 19(1):57-63. PubMed ID: 11332621
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Antegrade nailing of femoral shaft fractures combined with neck or distal femur fractures. A retrospective review of 25 cases, with a follow-up of 36-150 months.
    Okcu G; Aktuglu K
    Arch Orthop Trauma Surg; 2003 Dec; 123(10):544-50. PubMed ID: 13680274
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prevention of fracture at the distal locking site of the gamma nail. A biomechanical study.
    Lacroix H; Arwert H; Snijders CJ; Fontijne WP
    J Bone Joint Surg Br; 1995 Mar; 77(2):274-6. PubMed ID: 7706346
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical analysis of retrograde intramedullary nail fixation in distal femoral fractures.
    Chen SH; Yu TC; Chang CH; Lu YC
    Knee; 2008 Oct; 15(5):384-9. PubMed ID: 18722126
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ilizarov correction of malrotated femoral shaft fracture initially treated with an intramedullary nail: a case report.
    Brinker MR; Gugenheim JJ; O'Connor DP; London JC
    Am J Orthop (Belle Mead NJ); 2004 Oct; 33(10):489-93. PubMed ID: 15540848
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [A comparisive study between intramedullary interlocking nail and plate-screw fixation in the treatment of tibial shaft fractures].
    Huang P; Tang PF; Yao Q; Liang YT; Tao S; Zhang Q; Guo YZ; Liang XD; Wang Y
    Zhongguo Gu Shang; 2008 Apr; 21(4):261-3. PubMed ID: 19102183
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Clinical study on the rotational deformity after interlocking nailing in femur shaft fracture].
    Zhang BS; Liu HB; Wang XS; Jiang XY; Wei J; Liu DQ; Wang MY
    Zhonghua Yi Xue Za Zhi; 2005 Aug; 85(31):2211-3. PubMed ID: 16321187
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Closed interlocking nailing of femoral shaft fractures: assessment of technical complications and functional outcomes by comparison of a prospective database with retrospective review.
    Benirschke SK; Melder I; Henley MB; Routt ML; Smith DG; Chapman JR; Swiontkowski MF
    J Orthop Trauma; 1993; 7(2):118-22. PubMed ID: 8459295
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of muscular contractions on the stress analysis of distal femoral interlocking nailing.
    Shih KS; Tseng CS; Lee CC; Lin SC
    Clin Biomech (Bristol, Avon); 2008 Jan; 23(1):38-44. PubMed ID: 17945402
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Capture of the screw during percutaneous screw insertion.
    Mahaisavariya B; Riansuwan K; Songcharoen P
    Injury; 2004 Jun; 35(6):629-30. PubMed ID: 15135285
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Literature review of current techniques for the insertion of distal screws into intramedullary locking nails.
    Whatling GM; Nokes LD
    Injury; 2006 Feb; 37(2):109-19. PubMed ID: 16310192
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Ipsilateral fractures of the femoral and tibial diaphyses].
    Schiedts D; Mukisi M; Bouger D; Bastaraud H
    Rev Chir Orthop Reparatrice Appar Mot; 1996; 82(6):535-40. PubMed ID: 9122525
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimal location of a single distal interlocking screw in intramedullary nailing of distal third femoral shaft fractures.
    George CJ; Lindsey RW; Noble PC; Alexander JW; Kamaric E
    J Orthop Trauma; 1998 May; 12(4):267-72. PubMed ID: 9619462
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Interlocking intramedullary nails. An improved method of screw placement combining image intensification and laser light.
    Goulet JA; Londy F; Saltzman CL; Matthews LS
    Clin Orthop Relat Res; 1992 Aug; (281):199-203. PubMed ID: 1499210
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Distal femoral fixation: a biomechanical comparison of trigen retrograde intramedullary (i.m.) nail, dynamic condylar screw (DCS), and locking compression plate (LCP) condylar plate.
    Heiney JP; Barnett MD; Vrabec GA; Schoenfeld AJ; Baji A; Njus GO
    J Trauma; 2009 Feb; 66(2):443-9. PubMed ID: 19204519
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical comparison of expandable and locked intramedullary femoral nails.
    Oliveira ML; Lemon MA; Mears SC; Dinah AF; Waites MD; Knight TA; Belkoff SM
    J Orthop Trauma; 2008 Aug; 22(7):446-50. PubMed ID: 18670283
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.