BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

227 related articles for article (PubMed ID: 19326182)

  • 1. Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads.
    Stilling M; Nielsen KA; Søballe K; Rahbek O
    Clin Orthop Relat Res; 2009 Oct; 467(10):2644-50. PubMed ID: 19326182
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Do oxidized zirconium femoral heads reduce polyethylene wear in cemented THAs? A blinded randomized clinical trial.
    Zaoui A; Hage SE; Langlois J; Scemama C; Courpied JP; Hamadouche M
    Clin Orthop Relat Res; 2015 Dec; 473(12):3822-8. PubMed ID: 26113111
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.
    Karidakis GK; Karachalios T
    Clin Orthop Relat Res; 2015 Dec; 473(12):3836-45. PubMed ID: 26290343
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Oxidized zirconium versus cobalt-chrome femoral heads in total hip arthroplasty: a multicentre prospective randomized controlled trial with ten years' follow-up.
    Kayani B; Baawa-Ameyaw J; Fontalis A; Tahmassebi J; Wardle N; Middleton R; Stephen A; Hutchinson J; Haddad FS
    Bone Joint J; 2022 Jul; 104-B(7):833-843. PubMed ID: 35775177
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Long-term polyethylene wear rates and clinical outcomes of oxidized zirconium femoral heads on highly cross-linked polyethylene in total hip arthroplasty.
    Buckner BC; Urban ND; Cahoy KM; Lyden ER; Deans CF; Garvin KL
    Bone Joint J; 2024 Mar; 106-B(3 Supple A):38-43. PubMed ID: 38423114
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years.
    Garvin KL; White TC; Dusad A; Hartman CW; Martell J
    Clin Orthop Relat Res; 2015 Dec; 473(12):3829-35. PubMed ID: 26122983
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Five-year comparison of wear using oxidised zirconium and cobalt-chrome femoral heads in total hip arthroplasty: a multicentre randomised controlled trial.
    Jassim SS; Patel S; Wardle N; Tahmassebi J; Middleton R; Shardlow DL; Stephen A; Hutchinson J; Haddad FS
    Bone Joint J; 2015 Jul; 97-B(7):883-9. PubMed ID: 26130341
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Is Oxidized Zirconium Femoral Head Superior to Other Bearing Types in Total Hip Arthroplasty? A Systematic Review and Meta-Analysis.
    Malahias MA; Atrey A; Gu A; Chytas D; Nikolaou VS; Waddell JP
    J Arthroplasty; 2019 Aug; 34(8):1844-1852. PubMed ID: 31010775
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Minimum five-year follow-up wear measurement of longevity highly cross-linked polyethylene cup against cobalt-chromium or zirconia heads.
    Nakahara I; Nakamura N; Nishii T; Miki H; Sakai T; Sugano N
    J Arthroplasty; 2010 Dec; 25(8):1182-7. PubMed ID: 19879725
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Letter to the editor: Clinical comparison of polyethylene wear with zirconia or cobalt-chromium femoral heads.
    Roy ME; Whiteside LA
    Clin Orthop Relat Res; 2010 Feb; 468(2):624-5; author reply 626-7. PubMed ID: 19949908
    [No Abstract]   [Full Text] [Related]  

  • 11. Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size.
    Lachiewicz PF; Soileau ES; Martell JM
    Clin Orthop Relat Res; 2016 Feb; 474(2):365-71. PubMed ID: 25903943
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ceramic Femoral Heads Exhibit Lower Wear Rates Compared to Cobalt Chrome: A Meta-Analysis.
    Mertz KC; Yang J; Chung BC; Chen X; Mayfield CK; Heckmann ND
    J Arthroplasty; 2023 Feb; 38(2):397-405. PubMed ID: 36108994
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. A prospective, randomized study.
    Kim YH
    J Bone Joint Surg Am; 2005 Aug; 87(8):1769-76. PubMed ID: 16085617
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Oxinium modular femoral heads do not reduce polyethylene wear in cemented total hip arthroplasty at five years: a randomised trial of 120 hips using radiostereometric analysis.
    Jonsson BA; Kadar T; Havelin LI; Haugan K; Espehaug B; Indrekvam K; Furnes O; Hallan G
    Bone Joint J; 2015 Nov; 97-B(11):1463-9. PubMed ID: 26530646
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fifteen-Year Results of Total Hip Arthroplasty With Cobalt-Chromium Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years and Less.
    Rames RD; Stambough JB; Pashos GE; Maloney WJ; Martell JM; Clohisy JC
    J Arthroplasty; 2019 Jun; 34(6):1143-1149. PubMed ID: 30808529
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Wear analysis in THA utilizing oxidized zirconium and crosslinked polyethylene.
    Garvin KL; Hartman CW; Mangla J; Murdoch N; Martell JM
    Clin Orthop Relat Res; 2009 Jan; 467(1):141-5. PubMed ID: 18946711
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Long-term performance of ceramic and metal femoral heads on conventional polyethylene in young and active patients: a matched-pair analysis.
    Meftah M; Klingenstein GG; Yun RJ; Ranawat AS; Ranawat CS
    J Bone Joint Surg Am; 2013 Jul; 95(13):1193-7. PubMed ID: 23824387
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Excellent 20-Year Results of Total Hip Arthroplasty With Highly Cross-Linked Polyethylene on Cobalt-Chromium Femoral Heads in Patients ≤50 Years.
    Parilla FW; Youngman TR; Layon DR; Ince DC; Pashos GE; Maloney WJ; Clohisy JC
    J Arthroplasty; 2024 Feb; 39(2):409-415. PubMed ID: 37572728
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years.
    Lachiewicz PF; Heckman DS; Soileau ES; Mangla J; Martell JM
    Clin Orthop Relat Res; 2009 Dec; 467(12):3290-6. PubMed ID: 19690932
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Reduced wear of cross-linked UHMWPE using magnesia-stabilized zirconia femoral heads in a hip simulator.
    Roy ME; Whiteside LA; Magill ME; Katerberg BJ
    Clin Orthop Relat Res; 2011 Aug; 469(8):2337-45. PubMed ID: 21312076
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.