These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

98 related articles for article (PubMed ID: 19327108)

  • 1. A preliminary evaluation of the AQT90 FLEX Tnl immunoassay.
    Hedberg P; Wennecke G
    Clin Chem Lab Med; 2009; 47(3):376-8. PubMed ID: 19327108
    [No Abstract]   [Full Text] [Related]  

  • 2. Clinical evaluation of the troponin I assay on radiometer AQT90 FLEX and Beckman Coulter UniCel DxI 800 analyzers.
    Messinger M; Albert F; Rohde N
    Clin Lab; 2014; 60(12):2007-13. PubMed ID: 25651735
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of Abbott Architect high-sensitivity troponin I assay for haemolysis interference.
    Ryan JB; Wallace J; Sies CW; Florkowski CM; George PM
    Pathology; 2015 Dec; 47(7):716-8. PubMed ID: 26517635
    [No Abstract]   [Full Text] [Related]  

  • 4. MY APPROACH to low-level troponin elevations.
    Mueller CE
    Trends Cardiovasc Med; 2015 May; 25(4):373. PubMed ID: 25820092
    [No Abstract]   [Full Text] [Related]  

  • 5. Establishing a gradient of risk in patients with acute coronary syndromes using troponin I measurements.
    al-Harbi K; Suresh CG; Zubaid M; Akanji AO
    Med Princ Pract; 2002; 11(1):18-22. PubMed ID: 12116689
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The assessment of C-reactive protein does not improve the diagnosis of myocardial infarction using a high-sensitivity troponin immunoassay.
    Lippi G; Cervellin G
    Arch Pathol Lab Med; 2014 Jun; 138(6):725-6. PubMed ID: 24878010
    [No Abstract]   [Full Text] [Related]  

  • 7. False positive analytical interference of cardiac troponin I assays: an important consideration for method selection.
    Parry DM; Krahn J; Leroux M; Dalton J
    Clin Biochem; 1999 Nov; 32(8):667-9. PubMed ID: 10638952
    [No Abstract]   [Full Text] [Related]  

  • 8. Evaluation of high-sensitivity assays for cardiac troponin.
    Morrow DA; Antman EM
    Clin Chem; 2009 Jan; 55(1):5-8. PubMed ID: 19028812
    [No Abstract]   [Full Text] [Related]  

  • 9. [Cardiac troponin I cut-off: practice with the automated Immulite assay].
    Lavoinne A; Cauliez B
    Ann Biol Clin (Paris); 2003; 61(3):364-5. PubMed ID: 12825550
    [No Abstract]   [Full Text] [Related]  

  • 10. Evaluation of kryptor cardiac troponin I immunoassay.
    Lefèvre G; Graïne H; Bakkouch K; Garbarz E; Marlin G; Michel PL; Capeau J
    Ann Clin Biochem; 2002 Mar; 39(Pt 2):145-7. PubMed ID: 11928763
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Multimarker approach for diagnosis of acute myocardial infarction: better answers need better questions.
    Lindahl B
    Clin Chem; 2009 Jan; 55(1):9-11. PubMed ID: 19028816
    [No Abstract]   [Full Text] [Related]  

  • 12. Multicenter evaluation of the TOSOH AIA-pack second-generation cardiac troponin I assay.
    Pagani F; Stefini F; Micca G; Toppino M; Manoni F; Romano L; Hoffer P; Iervasi A; Caputo M; Dorizzi R; Zucchelli G; Panteghini M
    Clin Chem; 2004 Sep; 50(9):1707-9. PubMed ID: 15331518
    [No Abstract]   [Full Text] [Related]  

  • 13. Cardiac troponin.
    Arya SC
    Am J Clin Pathol; 2000 Sep; 114(3):486-7. PubMed ID: 10989650
    [No Abstract]   [Full Text] [Related]  

  • 14. Evaluation of a new troponin I method on the Bayer Immuno 1 immunoassay analyser.
    Clark GH; Kennon SR; Price CP
    J Immunoassay; 1999 Nov; 20(4):253-73. PubMed ID: 10595858
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Evaluation of the sensitivity and the specificity of Troponin I and T in the biological diagnosis of myocardial infarction at the Institute of Cardiology of Abidjan].
    Hauhouot-Attoungbre ML; Blessoue H; Edjeme NA; Yayo E; Diafouka F; Monnet D
    Ann Biol Clin (Paris); 2006; 64(1):96-8. PubMed ID: 16482682
    [No Abstract]   [Full Text] [Related]  

  • 16. Highly-sensitive troponin I in patients admitted to the emergency room with acute infections.
    Lippi G; Margapoti R; Aloe R; Cervellin G
    Eur J Intern Med; 2013 Jul; 24(5):e57-8. PubMed ID: 23419801
    [No Abstract]   [Full Text] [Related]  

  • 17. A dual gold nanoparticle conjugate-based lateral flow assay (LFA) method for the analysis of troponin I.
    Choi DH; Lee SK; Oh YK; Bae BW; Lee SD; Kim S; Shin YB; Kim MG
    Biosens Bioelectron; 2010 Apr; 25(8):1999-2002. PubMed ID: 20167468
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Serial changes in highly sensitive troponin I assay and early diagnosis of myocardial infarction.
    Keller T; Zeller T; Ojeda F; Tzikas S; Lillpopp L; Sinning C; Wild P; Genth-Zotz S; Warnholtz A; Giannitsis E; Möckel M; Bickel C; Peetz D; Lackner K; Baldus S; Münzel T; Blankenberg S
    JAMA; 2011 Dec; 306(24):2684-93. PubMed ID: 22203537
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Preliminary evaluation of a rapid, qualitative one step immunoassay of cardiac Troponin I in the acute myocardial infarction diagnosis].
    Mainet-González D; Galván-Cabrera JA; Sorell-Gómez L; Torres-Cabrera MB; Abdo-Cuza A; Castellano-Gutiérrez R; Padrón-Brito N; Palenzuela-Gardón D; Novoa-Pérez LI
    Invest Clin; 2004 Sep; 45(3):221-42. PubMed ID: 15469068
    [TBL] [Abstract][Full Text] [Related]  

  • 20. High-sensitive cardiac troponin assays: more information, more challenges.
    Seliger SL; deFilippi CR
    Coron Artery Dis; 2013 Dec; 24(8):625-7. PubMed ID: 24128888
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.