These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

278 related articles for article (PubMed ID: 19329852)

  • 21. Diagnostic and prognostic value of contrast-enhanced ultrasound in acute stroke.
    Allendoerfer J; Tanislav C
    Ultraschall Med; 2008 Sep; 29 Suppl 4():S210-4. PubMed ID: 18833499
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Transcranial Doppler correlation with angiography in detection of intracranial stenosis.
    Rorick MB; Nichols FT; Adams RJ
    Stroke; 1994 Oct; 25(10):1931-4. PubMed ID: 7916499
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Intracranial collateral pathways assessed by contrast-enhanced three-dimensional transcranial color-coded sonography.
    Wessels T; Bozzato A; Mull M; Klötzsch C
    Ultrasound Med Biol; 2004 Nov; 30(11):1435-40. PubMed ID: 15588953
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Diagnosis of middle cerebral artery occlusion with transcranial color-coded real-time sonography.
    Kimura K; Hashimoto Y; Hirano T; Uchino M; Ando M
    AJNR Am J Neuroradiol; 1996 May; 17(5):895-9. PubMed ID: 8733964
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Insufficient and absent acoustic temporal bone window: potential and limitations of transcranial contrast-enhanced color-coded sonography and contrast-enhanced power-based sonography.
    Postert T; Federlein J; Przuntek H; Büttner T
    Ultrasound Med Biol; 1997; 23(6):857-62. PubMed ID: 9300989
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Assessment of >/=50% and <50% intracranial stenoses by transcranial color-coded duplex sonography.
    Baumgartner RW; Mattle HP; Schroth G
    Stroke; 1999 Jan; 30(1):87-92. PubMed ID: 9880394
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of transcranial color-coded sonography and magnetic resonance angiography in acute ischemic stroke.
    Lien LM; Chen WH; Chen JR; Chiu HC; Tsai YF; Choi WM; Reynolds PS; Tegeler CH
    J Neuroimaging; 2001 Oct; 11(4):363-8. PubMed ID: 11677875
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Middle cerebral artery vasospasm: transcranial color-coded duplex sonography versus conventional nonimaging transcranial Doppler sonography.
    Swiat M; Weigele J; Hurst RW; Kasner SE; Pawlak M; Arkuszewski M; Al-Okaili RN; Swiercz M; Ustymowicz A; Opala G; Melhem ER; Krejza J
    Crit Care Med; 2009 Mar; 37(3):963-8. PubMed ID: 19237904
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Transcranial doppler sonography is not a valid diagnostic tool for detection of basilar artery stenosis or in-stent restenosis: a retrospective diagnostic study.
    Koh W; Kallenberg K; Karch A; Frank T; Knauth M; Bähr M; Liman J
    BMC Neurol; 2017 May; 17(1):89. PubMed ID: 28490351
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Clinical applications of transcranial color-coded duplex sonography.
    Krejza J; Baumgartner RW
    J Neuroimaging; 2004 Jul; 14(3):215-25. PubMed ID: 15228761
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Potential and limitations of transcranial color-coded sonography in stroke patients.
    Seidel G; Kaps M; Gerriets T
    Stroke; 1995 Nov; 26(11):2061-6. PubMed ID: 7482650
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Accuracy of transcranial colour-coded sonography in the diagnosis of anterior cerebral artery vasospasm.
    Turek G; Kochanowicz J; Rutkowski R; Krejza J; Lyson T; Gorbacz K; Zielinska-Turek J; Mariak Z
    Neurol Neurochir Pol; 2012; 46(3):233-8. PubMed ID: 22773509
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Contrast-enhanced transcranial color-coded sonography in acute hemispheric brain infarction.
    Postert T; Braun B; Meves S; Köster O; Przuntek H; Weber S; Büttner T
    Stroke; 1999 Sep; 30(9):1819-26. PubMed ID: 10471430
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Transcranial color-coded duplex sonography of the middle cerebral artery: more than just the M1 segment.
    Rogge A; Doepp F; Schreiber S; Valdueza JM
    J Ultrasound Med; 2015 Feb; 34(2):267-73. PubMed ID: 25614400
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Transcranial duplex sonography and CT angiography in acute stroke patients.
    Bar M; Skoloudík D; Roubec M; Hradílek P; Chmelová J; Czerný D; Procházka V; Langová K; Herzig R
    J Neuroimaging; 2010 Jul; 20(3):240-5. PubMed ID: 19226339
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Transcranial harmonic power duplex sonography for the evaluation of cerebral arteries.
    Seidel G; Christoph A; Algermissen C; Katzer T; Claasen L; Vidal-Langwasser M
    J Neuroimaging; 2000 Oct; 10(4):216-20. PubMed ID: 11147400
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A High Prevalence of Intracranial Stenosis in Patients with Coronary Artery Disease and the Diagnostic Value of Transcranial Duplex Sonography.
    Valaikiene J; Ryliskyte L; Valaika A; Puronaite R; Dementaviciene J; Vaitkevicius A; Badariene J; Butkuviene I; Kalinauskas G; Laucevicius A
    J Stroke Cerebrovasc Dis; 2019 Apr; 28(4):1015-1021. PubMed ID: 30630758
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Accuracy of transcranial Doppler compared with CT angiography in diagnosing arterial obstructions in acute ischemic strokes.
    Brunser AM; Lavados PM; Hoppe A; Lopez J; Valenzuela M; Rivas R
    Stroke; 2009 Jun; 40(6):2037-41. PubMed ID: 19359640
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Differentiation between intracerebral hemorrhage and ischemic stroke by transcranial color-coded duplex-sonography.
    Mäurer M; Shambal S; Berg D; Woydt M; Hofmann E; Georgiadis D; Lindner A; Becker G
    Stroke; 1998 Dec; 29(12):2563-7. PubMed ID: 9836768
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Classification of Intracranial Stenoses: Discrepancies between Transcranial Duplex Sonography and Computed Tomography Angiography.
    Danyel LA; Hadzibegovic S; Valdueza JM; Tietze A; Fuchs S; Schreiber SJ; Connolly F
    Ultrasound Med Biol; 2020 Aug; 46(8):1889-1895. PubMed ID: 32439356
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 14.