These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
407 related articles for article (PubMed ID: 19335346)
1. A comparison of Truview infant EVO2 laryngoscope with the Miller blade in neonates and infants. Singh R; Singh P; Vajifdar H Paediatr Anaesth; 2009 Apr; 19(4):338-42. PubMed ID: 19335346 [TBL] [Abstract][Full Text] [Related]
2. Comparison of TruView EVO2 with Miller laryngoscope in paediatric patients. Inal MT; Memis D; Kargi M; Oktay Z; Sut N Eur J Anaesthesiol; 2010 Nov; 27(11):950-4. PubMed ID: 20829701 [TBL] [Abstract][Full Text] [Related]
3. Evaluation of new laryngoscope blade for tracheal intubation, Truview EVO2: a manikin study. Miceli L; Cecconi M; Tripi G; Zauli M; Della Rocca G Eur J Anaesthesiol; 2008 Jun; 25(6):446-9. PubMed ID: 18294407 [TBL] [Abstract][Full Text] [Related]
4. The McCoy straight blade does not improve laryngoscopy and intubation in normal infants. Iohom G; Franklin R; Casey W; Lyons B Can J Anaesth; 2004 Feb; 51(2):155-9. PubMed ID: 14766692 [TBL] [Abstract][Full Text] [Related]
5. An evaluation of the TruView EVO2 laryngoscope. Li JB; Xiong YC; Wang XL; Fan XH; Li Y; Xu H; Ma Y; Deng XM Anaesthesia; 2007 Sep; 62(9):940-3. PubMed ID: 17697223 [TBL] [Abstract][Full Text] [Related]
6. A comparison of the STORZ video laryngoscope and standard direct laryngoscopy for intubation in the Pediatric airway--a randomized clinical trial. Vlatten A; Aucoin S; Litz S; Macmanus B; Soder C Paediatr Anaesth; 2009 Nov; 19(11):1102-7. PubMed ID: 19708910 [TBL] [Abstract][Full Text] [Related]
8. The efficacy of the Storz Miller 1 video laryngoscope in a simulated infant difficult intubation. Fiadjoe JE; Stricker PA; Hackell RS; Salam A; Gurnaney H; Rehman MA; Litman RS Anesth Analg; 2009 Jun; 108(6):1783-6. PubMed ID: 19448202 [TBL] [Abstract][Full Text] [Related]
9. Cricoid pressure with the Truview Evo2™ laryngoscope improves the glottic view. Kumar N; Behera D; Dali JS; Arya M; Gupta A Can J Anaesth; 2011 Sep; 58(9):810-4. PubMed ID: 21691934 [TBL] [Abstract][Full Text] [Related]
10. Comparison of the Truview PCD™ and the GlideScope(®) video laryngoscopes with direct laryngoscopy in pediatric patients: a randomized trial. Riveros R; Sung W; Sessler DI; Sanchez IP; Mendoza ML; Mascha EJ; Niezgoda J Can J Anaesth; 2013 May; 60(5):450-7. PubMed ID: 23435693 [TBL] [Abstract][Full Text] [Related]
11. A Macintosh laryngoscope blade for videolaryngoscopy reduces stylet use in patients with normal airways. van Zundert A; Maassen R; Lee R; Willems R; Timmerman M; Siemonsma M; Buise M; Wiepking M Anesth Analg; 2009 Sep; 109(3):825-31. PubMed ID: 19690253 [TBL] [Abstract][Full Text] [Related]
12. Training resident anesthesiologists in adult challenging intubation comparing Truview EVO2 and Macintosh laryngoscope: a preliminary study. Carlino C; Pastore JC; Battistini GM; Cancellieri F; De Caria D; Ruggieri N; Bordone G; Bellato V Minerva Anestesiol; 2009 Oct; 75(10):563-7. PubMed ID: 19461566 [TBL] [Abstract][Full Text] [Related]
13. Comparison of infant intubation through the TruView EVO2, TruView PCD, and Miller laryngoscope by paramedics during simulated infant cardiopulmonary resuscitation: A randomized crossover manikin study. Szarpak Ł; Kurowski A; Czyżewski Ł; Madziała M; Truszewski Z Am J Emerg Med; 2015 Jul; 33(7):872-5. PubMed ID: 25913081 [TBL] [Abstract][Full Text] [Related]
14. Management of the predicted difficult airway: a comparison of conventional blade laryngoscopy with video-assisted blade laryngoscopy and the GlideScope. Serocki G; Bein B; Scholz J; Dörges V Eur J Anaesthesiol; 2010 Jan; 27(1):24-30. PubMed ID: 19809328 [TBL] [Abstract][Full Text] [Related]
15. A randomized controlled study to evaluate and compare Truview blade with Macintosh blade for laryngoscopy and intubation under general anesthesia. Timanaykar RT; Anand LK; Palta S J Anaesthesiol Clin Pharmacol; 2011 Apr; 27(2):199-204. PubMed ID: 21772680 [TBL] [Abstract][Full Text] [Related]
16. The Cardiff paediatric laryngoscope blade: a comparison with the Miller size 1 and Macintosh size 2 laryngoscope blades. Jones RM; Jones PL; Gildersleve CD; Hall JE; Harding LJ; Chawathe MS Anaesthesia; 2004 Oct; 59(10):1016-9. PubMed ID: 15488063 [TBL] [Abstract][Full Text] [Related]
17. Role of the Truview EVO2 laryngoscope in the airway management of elective surgical patients: A comparison with the Macintosh laryngoscope. Saxena A; Madan M; Shrivastava U; Mittal A; Dwivedi Y; Agrawal A; Puri R Indian J Anaesth; 2013 May; 57(3):276-81. PubMed ID: 23983287 [TBL] [Abstract][Full Text] [Related]
18. A comparison of Truview EVO2 laryngoscope with Macintosh laryngoscope in routine airway management: A randomized crossover clinical trial. Arora S; Sayeed H; Bhardwaj N Saudi J Anaesth; 2013 Jul; 7(3):244-8. PubMed ID: 24015124 [TBL] [Abstract][Full Text] [Related]
19. Comparative evaluation of CMAC and Truview picture capture device for endotracheal intubation in neonates and infants undergoing elective surgeries: A prospective randomized control trial. Gupta A; Kamal G; Gupta A; Sehgal N; Bhatla S; Kumar R Paediatr Anaesth; 2018 Dec; 28(12):1148-1153. PubMed ID: 30511796 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of Truview evo2 Laryngoscope In Anticipated Difficult Intubation - A Comparison To Macintosh Laryngoscope. Singh I; Khaund A; Gupta A Indian J Anaesth; 2009 Apr; 53(2):164-8. PubMed ID: 20640117 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]