These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

308 related articles for article (PubMed ID: 19335867)

  • 1. Multiple ICD discharges associated with lead fracture without triggering of high impedance alert.
    Donaldson DM; Singh JP; Heist EK; Mela T; Ruskin JN; Das S
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):543-6. PubMed ID: 19335867
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Limitation of programmed alerts to predict ICD lead failures.
    Vlay SC
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):554-5. PubMed ID: 19335870
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Analysis of pacing/defibrillator lead failure using device diagnostics and pacing maneuvers.
    Chung EH; Casavant D; John RM
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):547-9. PubMed ID: 19335868
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fatal outcome in a pacemaker-dependent patient.
    Undavia M; Fischer A; Mehta D
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):550-3. PubMed ID: 19335869
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture.
    Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y
    Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Downloadable algorithm to reduce inappropriate shocks caused by fractures of implantable cardioverter-defibrillator leads.
    Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Stadler RW; Gillberg JM; Patel AS; Ellenbogen KA
    Circulation; 2008 Nov; 118(21):2122-9. PubMed ID: 18981299
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure.
    Spencker S; Coban N; Koch L; Schirdewan A; Müller D
    Europace; 2009 Apr; 11(4):483-8. PubMed ID: 19103654
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert.
    Gelder RN; Gunderson BD
    Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Automatic impedance monitoring and patient alert feature in implantable cardioverter defibrillators: being alert for the unexpected!
    Duru F; Luechinger R; Scharf C; Brunckhorst C
    J Cardiovasc Electrophysiol; 2005 Apr; 16(4):444-8. PubMed ID: 15828892
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Patient Alert to detect ICD lead failure: efficacy, limitations, and implications for future algorithms.
    Vollmann D; Erdogan A; Himmrich E; Neuzner J; Becker D; Unterberg-Buchwald C; Sperzel J
    Europace; 2006 May; 8(5):371-6. PubMed ID: 16635998
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Implantable cardiac defibrillator lead failure or myopotential oversensing? An approach to the diagnosis of noise on lead electrograms.
    Kowalski M; Ellenbogen KA; Wood MA; Friedman PL
    Europace; 2008 Aug; 10(8):914-7. PubMed ID: 18565976
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Patient alert in implantable cardioverter defibrillators: toy or tool?
    Becker R; Ruf-Richter J; Senges-Becker JC; Bauer A; Weretka S; Voss F; Katus HA; Schoels W
    J Am Coll Cardiol; 2004 Jul; 44(1):95-8. PubMed ID: 15234415
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sensing failure associated with the Medtronic Sprint Fidelis defibrillator lead.
    Kenigsberg DN; Mirchandani S; Dover AN; Kowalski M; Wood MA; Shepard RK; Kalahasty G; Stein KM; Markowitz SM; Iwai S; Shah BK; Lerman BB; Mittal S; Ellenbogen KA
    J Cardiovasc Electrophysiol; 2008 Mar; 19(3):270-4. PubMed ID: 18179527
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An algorithm to predict implantable cardioverter-defibrillator lead failure.
    Gunderson BD; Patel AS; Bounds CA; Shepard RK; Wood MA; Ellenbogen KA
    J Am Coll Cardiol; 2004 Nov; 44(9):1898-902. PubMed ID: 15519026
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead.
    Kallinen LM; Hauser RG; Lee KW; Almquist AK; Katsiyiannis WT; Tang CY; Melby DP; Gornick CC
    Heart Rhythm; 2008 Jun; 5(6):775-9. PubMed ID: 18534361
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accelerating risk of Fidelis lead fracture.
    Farwell D; Green MS; Lemery R; Gollob MH; Birnie DH
    Heart Rhythm; 2008 Oct; 5(10):1375-9. PubMed ID: 18783996
    [TBL] [Abstract][Full Text] [Related]  

  • 17. "Cold can for a hot case": use of a coronary sinus shocking lead in association with cold can to achieve successful defibrillation.
    Hamid S; Khan S; Rinaldi CA
    Pacing Clin Electrophysiol; 2009 Apr; 32(4):561-2. PubMed ID: 19335872
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Multiple high lead impedances in an implantable-cardioverter defibrillator system: what is the mechanism?
    Ho RT
    Pacing Clin Electrophysiol; 2013 Sep; 36(9):1173-5. PubMed ID: 23594162
    [No Abstract]   [Full Text] [Related]  

  • 19. Risk factors for implantable defibrillator lead fracture in a recalled and a nonrecalled lead.
    Morrison TB; Rea RF; Hodge DO; Crusan D; Koestler C; Asirvatham SJ; Bradley D; Shen WK; Munger TM; Hammill SC; Friedman PA
    J Cardiovasc Electrophysiol; 2010 Jun; 21(6):671-7. PubMed ID: 20082653
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance of Lead Integrity Alert to assist in the clinical diagnosis of implantable cardioverter defibrillator lead failures: analysis of different implantable cardioverter defibrillator leads.
    Ellenbogen KA; Gunderson BD; Stromberg KD; Swerdlow CD
    Circ Arrhythm Electrophysiol; 2013 Dec; 6(6):1169-77. PubMed ID: 24099976
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.