These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

159 related articles for article (PubMed ID: 19342960)

  • 41. Arterial stiffness in hemodialysis: which parameter to measure to predict cardiovascular mortality?
    Othmane Tel H; Nemcsik J; Fekete BC; Deák G; Egresits J; Fodor E; Logan AG; Németh ZK; Járai Z; Szabó T; Szathmári M; Kiss I; Tislér A
    Kidney Blood Press Res; 2009; 32(4):250-7. PubMed ID: 19752574
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Noninvasive determination of carotid-femoral pulse wave velocity depends critically on assessment of travel distance: a comparison with invasive measurement.
    Weber T; Ammer M; Rammer M; Adji A; O'Rourke MF; Wassertheurer S; Rosenkranz S; Eber B
    J Hypertens; 2009 Aug; 27(8):1624-30. PubMed ID: 19531964
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Regional and Global Aortic Pulse Wave Velocity in Patients with Abdominal Aortic Aneurysm.
    Lindenberger M; Ziegler M; Bjarnegård N; Ebbers T; Dyverfeldt P
    Eur J Vasc Endovasc Surg; 2024 Mar; 67(3):506-513. PubMed ID: 37777048
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Improvement in arterial stiffness following cardiac rehabilitation.
    Laskey W; Siddiqi S; Wells C; Lueker R
    Int J Cardiol; 2013 Sep; 167(6):2734-8. PubMed ID: 22795404
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Aortic compliance following EVAR and the influence of different endografts: determination using dynamic MRA.
    van Herwaarden JA; Muhs BE; Vincken KL; van Prehn J; Teutelink A; Bartels LW; Moll FL; Verhagen HJ
    J Endovasc Ther; 2006 Jun; 13(3):406-14. PubMed ID: 16784330
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Validation and reproducibility of aortic pulse wave velocity as assessed with velocity-encoded MRI.
    Grotenhuis HB; Westenberg JJ; Steendijk P; van der Geest RJ; Ottenkamp J; Bax JJ; Jukema JW; de Roos A
    J Magn Reson Imaging; 2009 Sep; 30(3):521-6. PubMed ID: 19711407
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Improvement of aortic reflection wave responses 6 months after stopping smoking: a prospective study.
    Polónia J; Barbosa L; Silva JA; Rosas M
    Blood Press Monit; 2009 Apr; 14(2):69-75. PubMed ID: 19305186
    [TBL] [Abstract][Full Text] [Related]  

  • 48. [Utility of SVV (stroke volume variation) during abdominal aortic surgery].
    Yamagishi A; Kunisawa T; Kurosawa A; Sasakawa T; Ueno M; Takahata O; Iwasaki H
    Masui; 2010 Feb; 59(2):197-201. PubMed ID: 20169957
    [TBL] [Abstract][Full Text] [Related]  

  • 49. [Analysis of intrasac pressure after the implantation of endoprotheses with different diameters, in an animal model of abdominal aortic aneurysm].
    Vaquero C; Arce N; Diago MV; Grajal C; Agudo J; Martinez R
    Rev Port Cir Cardiotorac Vasc; 2007; 14(3):157-60. PubMed ID: 18167576
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Pulse wave velocity assessment by external noninvasive devices and phase-contrast magnetic resonance imaging in the obese.
    Joly L; Perret-Guillaume C; Kearney-Schwartz A; Salvi P; Mandry D; Marie PY; Karcher G; Rossignol P; Zannad F; Benetos A
    Hypertension; 2009 Aug; 54(2):421-6. PubMed ID: 19506096
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Aneurysm sac pressure monitoring: effect of pulsatile motion of the pressure sensor on the interpretation of measurements.
    Hinnen JW; Koning OH; Vlaanderen E; van Bockel JH; Hamming JF
    J Endovasc Ther; 2006 Apr; 13(2):145-51. PubMed ID: 16643068
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Preoperative haemodynamic parameters and the immediate outcome after open repair of ruptured abdominal aortic aneurysms.
    Giordano S; Biancari F; Loponen P; Wistbacka JO; Luther M
    Interact Cardiovasc Thorac Surg; 2009 Sep; 9(3):491-3. PubMed ID: 19567498
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Preliminary results by flow-sensitive magnetic resonance imaging after Tiron David I procedure with an anatomically shaped ascending aortic graft.
    Frydrychowicz A; Berger A; Stalder AF; Markl M
    Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):155-8. PubMed ID: 19386661
    [TBL] [Abstract][Full Text] [Related]  

  • 54. eComment: Ruptured abdominal aortic aneurysms--endovascular treatment and hemodynamic parameters.
    Hudorovic N
    Interact Cardiovasc Thorac Surg; 2009 Sep; 9(3):493. PubMed ID: 19687049
    [No Abstract]   [Full Text] [Related]  

  • 55. Correlation between pulse wave velocity and fluid distribution in hemodialysis patients.
    Zheng D; Cheng LT; Zhuang Z; Gu Y; Tang LJ; Wang T
    Blood Purif; 2009; 27(3):248-52. PubMed ID: 19190400
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Aortic stiffness and the balance between cardiac oxygen supply and demand: the Rotterdam Study.
    Guelen I; Mattace-Raso FU; van Popele NM; Westerhof BE; Hofman A; Witteman JC; Bos WJ
    J Hypertens; 2008 Jun; 26(6):1237-43. PubMed ID: 18475163
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Mechanical cardiac support and abdominal vascular surgery.
    Tirilomis T
    Interact Cardiovasc Thorac Surg; 2008 May; 7(3):525. PubMed ID: 18495729
    [No Abstract]   [Full Text] [Related]  

  • 58. Analysis of blood flow behaviour in custom stent grafts.
    Guivier-Curien C; Deplano V; Bertrand E; Dominique Singland J; Koskas F
    J Biomech; 2009 Aug; 42(11):1754-61. PubMed ID: 19539937
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Effect of new-onset diabetes mellitus on arterial stiffness in renal transplantation.
    Opazo Saez A; Kos M; Witzke O; Kribben A; Nürnberger J
    Transpl Int; 2008 Oct; 21(10):930-5. PubMed ID: 18537923
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Hybrid repair of complex thoracoabdominal aortic aneurysms using applied endovascular strategies combined with visceral and renal revascularization.
    Biasi L; Ali T; Loosemore T; Morgan R; Loftus I; Thompson M
    J Thorac Cardiovasc Surg; 2009 Dec; 138(6):1331-8. PubMed ID: 19660382
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]