These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

97 related articles for article (PubMed ID: 1934486)

  • 1. Serum index identifies lipemic samples causing interference with bilirubin assay on Hitachi 717.
    Pearson JR; Wells R; Wells A
    Clin Chem; 1991 Nov; 37(11):2014-5. PubMed ID: 1934486
    [No Abstract]   [Full Text] [Related]  

  • 2. Correction of patient results for Beckman Coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids: a practical approach.
    Vermeer HJ; Steen G; Naus AJ; Goevaerts B; Agricola PT; Schoenmakers CH
    Clin Chem Lab Med; 2007; 45(1):114-9. PubMed ID: 17243928
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Evaluation of the interference of hemoglobin, bilirubin, and lipids on Roche Cobas 6000 assays.
    Ji JZ; Meng QH
    Clin Chim Acta; 2011 Aug; 412(17-18):1550-3. PubMed ID: 21575617
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A single nonaqueous diazo reagent for the rapid determination of bilirubin in serum without lipemic interference.
    Morin LG
    Clin Chim Acta; 1976 Aug; 71(1):9-14. PubMed ID: 971528
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Monoclonal and polyclonal immunoglobulin interference in a conjugated bilirubin assay.
    Song L; Kelly KA; Butch AW
    Arch Pathol Lab Med; 2014 Jul; 138(7):950-4. PubMed ID: 24978922
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Drug interference in clinical biochemistry.
    Sunderman FW
    CRC Crit Rev Clin Lab Sci; 1970 Jul; 1(3):427-49. PubMed ID: 4938323
    [No Abstract]   [Full Text] [Related]  

  • 7. Bilirubin interference in determinations of creatinine with the Hitachi 737 analyzer.
    Guy JM; Legg EF
    Clin Chem; 1990 Oct; 36(10):1851-2. PubMed ID: 2208673
    [No Abstract]   [Full Text] [Related]  

  • 8. Naproxen metabolites interfere with certain bilirubin assays: elimination of interference by using a Roche bilirubin assay on the Hitachi 917 analyzer.
    Dasgupta A; Langman LJ; Johnson M; Chow L
    Am J Clin Pathol; 2010 Jun; 133(6):878-83. PubMed ID: 20472845
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Enzymatic determination of sodium, potassium, and chloride in abnormal (hemolyzed, icteric, lipemic, paraproteinemic, or uremic) serum samples compared with indirect determination with ion-selective electrodes.
    Hübl W; Wejbora R; Shafti-Keramat I; Haider A; Hajdusich P; Bayer PM
    Clin Chem; 1994 Aug; 40(8):1528-31. PubMed ID: 8044991
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Conjugated, but not unconjugated, bilirubin negatively interferes in Hitachi 747 assay of inorganic phosphorus.
    Alvarez F; Whalen K; Scott MG
    Clin Chem; 1993 Nov; 39(11 Pt 1):2345-6. PubMed ID: 8222236
    [No Abstract]   [Full Text] [Related]  

  • 11. Evaluation of the In Vitro Interference of Hemoglobin, Lipids, and Bilirubin on the Measurement of Plasma Advanced Oxidation Protein Products.
    Cargnin LP; Hausen BS; Tatsch E; Sangoi MB; Moresco RN
    Clin Lab; 2016 Aug; 62(8):1585-1589. PubMed ID: 28164612
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Bilirubin interference in the colorimetric assay of plasma vitamin E.
    Desai ID; Martinez FE
    Clin Chim Acta; 1986 Feb; 154(3):247-50. PubMed ID: 3955850
    [No Abstract]   [Full Text] [Related]  

  • 13. [Haemolysis and turbidity influence on three analysis methods of quantitative determination of total and conjugated bilirubin on ADVIA 1650].
    Gobert De Paepe E; Munteanu G; Schischmanoff PO; Porquet D
    Ann Biol Clin (Paris); 2008; 66(2):175-82. PubMed ID: 18390427
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Detecting paraprotein interference on a direct bilirubin assay by reviewing the photometric reaction data.
    García-González E; Aramendía M; González-Tarancón R; Romero-Sánchez N; Rello L
    Clin Chem Lab Med; 2017 Jul; 55(8):1178-1185. PubMed ID: 28076302
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Electrochemical homogeneous enzyme immunoassay of theophylline in hemolyzed, icteric, and lipemic samples.
    Yao H; Jenkins SH; Pesce AJ; Halsall HB; Heineman WR
    Clin Chem; 1993 Jul; 39(7):1432-4. PubMed ID: 8330402
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Paraprotein interference in an assay of conjugated bilirubin.
    Nauti A; Barassi A; Merlini G; d'Eril GV
    Clin Chem; 2005 Jun; 51(6):1076-7. PubMed ID: 15914800
    [No Abstract]   [Full Text] [Related]  

  • 17. Technical performance evaluation of BM/Hitachi 747-200 serum fructosamine assay.
    Lin MJ; Hoke C; Ettinger B; Coyne RV
    Clin Chem; 1996 Feb; 42(2):244-8. PubMed ID: 8595718
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the interference due to haemoglobin, bilirubin and lipids on Immulite 2500 assays: a practical approach.
    Steen G; Klerk A; Laan Kv; Eppens EF
    Ann Clin Biochem; 2011 Mar; 48(Pt 2):170-5. PubMed ID: 21355012
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hemoglobin, bilirubin, and lipid interference on Roche Cobas 6000 assays.
    Szoke D; Braga F; Valente C; Panteghini M
    Clin Chim Acta; 2012 Jan; 413(1-2):339-41; author reply 342-3. PubMed ID: 22001518
    [No Abstract]   [Full Text] [Related]  

  • 20. False positive acetaminophen levels associated with hyperbilirubinemia.
    Beuhler MC; Curry SC
    Clin Toxicol (Phila); 2005; 43(3):167-70. PubMed ID: 15902790
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.