BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

251 related articles for article (PubMed ID: 19345614)

  • 1. Lateral fluoroscopic guide to prevent occipitocervical and atlantoaxial joint violation during C1 lateral mass screw placement.
    Yeom JS; Buchowski JM; Park KW; Chang BS; Lee CK; Riew KD
    Spine J; 2009 Jul; 9(7):574-9. PubMed ID: 19345614
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Harms technique of C1-C2 fixation with polyaxial screws and rods].
    Stulík J; Vyskocil T; Sebesta P; Kryl J
    Acta Chir Orthop Traumatol Cech; 2005; 72(1):22-7. PubMed ID: 15860148
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A safe screw trajectory for atlantoaxial transarticular fixation achieved using an aiming device.
    Neo M; Sakamoto T; Fujibayashi S; Nakamura T
    Spine (Phila Pa 1976); 2005 May; 30(9):E236-42. PubMed ID: 15864141
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Anatomic determination of optimal entry point and direction for C1 lateral mass screw placement.
    Blagg SE; Don AS; Robertson PA
    J Spinal Disord Tech; 2009 Jun; 22(4):233-9. PubMed ID: 19494741
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Anatomic considerations of anterior transarticular screw fixation for atlantoaxial instability.
    Lu J; Ebraheim NA; Yang H; Heck BE; Yeasting RA
    Spine (Phila Pa 1976); 1998 Jun; 23(11):1229-35; discussion 1236. PubMed ID: 9636976
    [TBL] [Abstract][Full Text] [Related]  

  • 6. C1 lateral mass screw insertion from the caudal-dorsal to the cranial-ventral direction as an alternate method for C1 fixation: A quantitative anatomical and morphometric evaluation.
    Senoglu M; Karadag A; Kinali B; Bozkurt B; Icke C; Halacoglu Savran D; Middlebrooks EH
    J Clin Neurosci; 2017 Aug; 42():176-181. PubMed ID: 28522371
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Routine insertion of the lateral mass screw via the posterior arch for C1 fixation: feasibility and related complications.
    Yeom JS; Kafle D; Nguyen NQ; Noh W; Park KW; Chang BS; Lee CK; Riew KD
    Spine J; 2012 Jun; 12(6):476-83. PubMed ID: 22795381
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fluoroscopically guided anterior atlantoaxial transarticular screws: a feasibility and trajectory study using CT-based simulation software.
    Padua MR; Yeom JS; Lee SY; Lee SM; Kim HJ; Chang BS; Lee CK; Riew KD
    Spine J; 2013 Nov; 13(11):1455-63. PubMed ID: 23850256
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Anatomic considerations for the pedicle screw placement in the first cervical vertebra.
    Ma XY; Yin QS; Wu ZH; Xia H; Liu JF; Zhong SZ
    Spine (Phila Pa 1976); 2005 Jul; 30(13):1519-23. PubMed ID: 15990666
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The feasibility of microscope-assisted "free-hand" C1 lateral mass screw insertion without fluoroscopy.
    Liu G; Buchowski JM; Shen H; Yeom JS; Riew KD
    Spine (Phila Pa 1976); 2008 Apr; 33(9):1042-9. PubMed ID: 18427327
    [TBL] [Abstract][Full Text] [Related]  

  • 11. C1 lateral mass anatomy: Proper placement of lateral mass screws.
    Seal C; Zarro C; Gelb D; Ludwig S
    J Spinal Disord Tech; 2009 Oct; 22(7):516-23. PubMed ID: 20075816
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Freehand C1 lateral mass screw fixation technique: our experience.
    Simsek S; Yigitkanli K; Seckin H; Akyol C; Belen D; Bavbek M
    Surg Neurol; 2009 Dec; 72(6):676-81. PubMed ID: 19818472
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Atlas (C1) lateral mass screw placement using the intersection between lateral mass and inferomedial edge of the posterior arch: a cadaveric study.
    Liawrungrueang W; Riew KD; Sugandhavesa N; Bunmaprasert T
    Eur Spine J; 2022 Dec; 31(12):3443-3451. PubMed ID: 36117232
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimal trajectory for the atlantooccipital transarticular screw.
    Lee KM; Yeom JS; Lee JO; Buchowski JM; Park KW; Chang BS; Lee CK; Riew KD
    Spine (Phila Pa 1976); 2010 Jul; 35(16):1562-70. PubMed ID: 20375856
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Safe zone for C1 lateral mass screws: anatomic and radiological study.
    Simsek S; Yigitkanli K; Turba UC; Comert A; Seçkin H; Tekdemir I; Elhan A
    Neurosurgery; 2009 Dec; 65(6):1154-60; discussion 1160. PubMed ID: 19934975
    [TBL] [Abstract][Full Text] [Related]  

  • 16. An anatomic study to determine the optimal entry point, medial angles, and effective length for safe fixation using posterior C1 lateral mass screws.
    Hu Y; Dong WX; Spiker WR; Yuan ZS; Sun XY; Zhang J; Xie H; Albert TJ
    Spine (Phila Pa 1976); 2015 Feb; 40(4):E191-8. PubMed ID: 25398038
    [TBL] [Abstract][Full Text] [Related]  

  • 17. C1 lateral mass screw-induced occipital neuralgia: a report of two cases.
    Conroy E; Laing A; Kenneally R; Poynton AR
    Eur Spine J; 2010 Mar; 19(3):474-6. PubMed ID: 19856190
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Risk of internal carotid artery injury during C1 screw placement: analysis of 160 computed tomography angiograms.
    Estillore RP; Buchowski JM; Minh do V; Park KW; Chang BS; Lee CK; Riew KD; Yeom JS
    Spine J; 2011 Apr; 11(4):316-23. PubMed ID: 21474083
    [TBL] [Abstract][Full Text] [Related]  

  • 19. C1 lateral mass screw placement via the posterior arch: a technique comparison and anatomic analysis.
    Lin JM; Hipp JA; Reitman CA
    Spine J; 2013 Nov; 13(11):1549-55. PubMed ID: 23953731
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Experimental study of posterior pedicle screw placement on atlas].
    Ma X; Zhong S; Liu J; Yin Q; Xu D; Ding Z; Li Z
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2004 Sep; 18(5):392-5. PubMed ID: 15460052
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.