BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

217 related articles for article (PubMed ID: 19345807)

  • 1. A novel platform for in vitro analysis of torque, forces, and three-dimensional file displacements during root canal preparations: application to ProTaper rotary files.
    Diop A; Maurel N; Oiknine M; Patoor E; Machtou P
    J Endod; 2009 Apr; 35(4):568-72. PubMed ID: 19345807
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Analysis of mechanical preparations in extracted teeth using ProTaper rotary instruments: value of the safety quotient.
    Blum JY; Machtou P; Ruddle C; Micallef JP
    J Endod; 2003 Sep; 29(9):567-75. PubMed ID: 14503829
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of forces generated during root canal shaping and residual stresses of three nickel-titanium rotary files by using a three-dimensional finite-element analysis.
    Kim HC; Cheung GS; Lee CJ; Kim BM; Park JK; Kang SI
    J Endod; 2008 Jun; 34(6):743-7. PubMed ID: 18498904
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of electropolishing on torque and force during simulated root canal preparation with ProTaper shaping files.
    Boessler C; Paque F; Peters OA
    J Endod; 2009 Jan; 35(1):102-6. PubMed ID: 19084135
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A comparative computational analysis of the mechanical behavior of two nickel-titanium rotary endodontic instruments.
    Necchi S; Petrini L; Taschieri S; Migliavacca F
    J Endod; 2010 Aug; 36(8):1380-4. PubMed ID: 20647101
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of clinical use on the cyclic fatigue resistance of ProTaper nickel-titanium rotary instruments.
    Ounsi HF; Salameh Z; Al-Shalan T; Ferrari M; Grandini S; Pashley DH; Tay FR
    J Endod; 2007 Jun; 33(6):737-41. PubMed ID: 17509417
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparison of torque required to fracture three different nickel-titanium rotary instruments around curves of the same angle but of different radius when bound at the tip.
    Booth JR; Scheetz JP; Lemons JE; Eleazer PD
    J Endod; 2003 Jan; 29(1):55-7. PubMed ID: 12540222
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of phase transformation on the torsional and bending properties of nickel-titanium rotary endodontic instruments.
    Miyai K; Ebihara A; Hayashi Y; Doi H; Suda H; Yoneyama T
    Int Endod J; 2006 Feb; 39(2):119-26. PubMed ID: 16454792
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation.
    Bier CA; Shemesh H; Tanomaru-Filho M; Wesselink PR; Wu MK
    J Endod; 2009 Feb; 35(2):236-8. PubMed ID: 19166781
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of liquid and paste-type lubricants on torque values during simulated rotary root canal instrumentation.
    Peters OA; Boessler C; Zehnder M
    Int Endod J; 2005 Apr; 38(4):223-9. PubMed ID: 15810972
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An in vitro comparison of torsional stress and cyclic fatigue resistance of ProFile GT and ProFile GT Series X rotary nickel-titanium files.
    Kramkowski TR; Bahcall J
    J Endod; 2009 Mar; 35(3):404-7. PubMed ID: 19249605
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Torsional resistance of retreatment instruments.
    Lopes HP; Elias CN; Vedovello GA; Bueno CE; Mangelli M; Siqueira JF
    J Endod; 2011 Oct; 37(10):1442-5. PubMed ID: 21924199
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Defects in nickel-titanium instruments after clinical use. Part 1: Relationship between observed imperfections and factors leading to such defects in a cohort study.
    Shen Y; Haapasalo M; Cheung GS; Peng B
    J Endod; 2009 Jan; 35(1):129-32. PubMed ID: 19084142
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative analysis of torsional and bending stresses in two mathematical models of nickel-titanium rotary instruments: ProTaper versus ProFile.
    Berutti E; Chiandussi G; Gaviglio I; Ibba A
    J Endod; 2003 Jan; 29(1):15-9. PubMed ID: 12540212
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of forces developed during mechanical preparation of extracted teeth using RaCe rotary instruments and ProFiles.
    da Silva FM; Kobayashi C; Suda H
    Int Endod J; 2005 Jan; 38(1):17-21. PubMed ID: 15606818
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Defects in nickel-titanium instruments after clinical use. Part 2: Fractographic analysis of fractured surface in a cohort study.
    Shen Y; Cheung GS; Peng B; Haapasalo M
    J Endod; 2009 Jan; 35(1):133-6. PubMed ID: 19084143
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Separation incidence of protaper rotary instruments: a large cohort clinical evaluation.
    Wolcott S; Wolcott J; Ishley D; Kennedy W; Johnson S; Minnich S; Meyers J
    J Endod; 2006 Dec; 32(12):1139-41. PubMed ID: 17174668
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cleaning efficiency of nickel-titanium GT and .04 rotary files when used in a torque-controlled rotary handpiece.
    Suffridge CB; Hartwell GR; Walker TL
    J Endod; 2003 May; 29(5):346-8. PubMed ID: 12775008
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Defects in nickel-titanium instruments after clinical use. Part 5: single use from endodontic specialty practices.
    Shen Y; Coil JM; McLean AG; Hemerling DL; Haapasalo M
    J Endod; 2009 Oct; 35(10):1363-7. PubMed ID: 19801231
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analysis of forces developed during mechanical preparation of extracted teeth using Profile NiTi rotary instruments.
    Blum JY; Cohen A; Machtou P; Micallef JP
    Int Endod J; 1999 Jan; 32(1):24-31. PubMed ID: 10356466
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.