BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

768 related articles for article (PubMed ID: 19346122)

  • 1. High-performance UV-curable epoxy resin-based microarray and microfluidic immunoassay devices.
    Yu L; Liu Y; Gan Y; Li CM
    Biosens Bioelectron; 2009 Jun; 24(10):2997-3002. PubMed ID: 19346122
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Flow-through functionalized PDMS microfluidic channels with dextran derivative for ELISAs.
    Yu L; Li CM; Liu Y; Gao J; Wang W; Gan Y
    Lab Chip; 2009 May; 9(9):1243-7. PubMed ID: 19370243
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Highly sensitive poly[glycidyl methacrylate-co-poly(ethylene glycol) methacrylate] brush-based flow-through microarray immunoassay device.
    Liu Y; Wang W; Hu W; Lu Z; Zhou X; Li CM
    Biomed Microdevices; 2011 Aug; 13(4):769-77. PubMed ID: 21547537
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Screen-printed microfluidic device for electrochemical immunoassay.
    Dong H; Li CM; Zhang YF; Cao XD; Gan Y
    Lab Chip; 2007 Dec; 7(12):1752-8. PubMed ID: 18030397
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A label-free protein microfluidic array for parallel immunoassays.
    Wang ZH; Meng YH; Ying PQ; Qi C; Jin G
    Electrophoresis; 2006 Oct; 27(20):4078-85. PubMed ID: 17054092
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Surface modification for enhancing antibody binding on polymer-based microfluidic device for enzyme-linked immunosorbent assay.
    Bai Y; Koh CG; Boreman M; Juang YJ; Tang IC; Lee LJ; Yang ST
    Langmuir; 2006 Oct; 22(22):9458-67. PubMed ID: 17042569
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Microfluidic systems integrated with two-dimensional surface plasmon resonance phase imaging systems for microarray immunoassay.
    Lee KH; Su YD; Chen SJ; Tseng FG; Lee GB
    Biosens Bioelectron; 2007 Nov; 23(4):466-72. PubMed ID: 17618110
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Parallel detection and quantification using nine immunoassays in a protein microarray for drug from serum samples.
    Du H; Yang W; Xing W; Su Y; Cheng J
    Biomed Microdevices; 2005 Jun; 7(2):143-6. PubMed ID: 15940429
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Microvalves actuated sandwich immunoassay on an integrated microfluidic system.
    Gao X; Jiang L; Su X; Qin J; Lin B
    Electrophoresis; 2009 Jul; 30(14):2481-7. PubMed ID: 19639569
    [TBL] [Abstract][Full Text] [Related]  

  • 10. PDMS microfludic device for optical detection of protein immunoassay using gold nanoparticles.
    Luo C; Fu Q; Li H; Xu L; Sun M; Ouyang Q; Chen Y; Ji H
    Lab Chip; 2005 Jul; 5(7):726-9. PubMed ID: 15970965
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples.
    Bhattacharyya A; Klapperich CM
    Biomed Microdevices; 2007 Apr; 9(2):245-51. PubMed ID: 17165125
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An electrokinetically-controlled immunoassay for simultaneous detection of multiple microbial antigens.
    Gao Y; Hu G; Lin FY; Sherman PM; Li D
    Biomed Microdevices; 2005 Dec; 7(4):301-12. PubMed ID: 16404508
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microfluidic biochip for chemiluminescent detection of allergen-specific antibodies.
    Heyries KA; Loughran MG; Hoffmann D; Homsy A; Blum LJ; Marquette CA
    Biosens Bioelectron; 2008 Jul; 23(12):1812-8. PubMed ID: 18396032
    [TBL] [Abstract][Full Text] [Related]  

  • 14. In situ microarray fabrication and analysis using a microfluidic flow cell array integrated with surface plasmon resonance microscopy.
    Liu J; Eddings MA; Miles AR; Bukasov R; Gale BK; Shumaker-Parry JS
    Anal Chem; 2009 Jun; 81(11):4296-301. PubMed ID: 19408947
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High performance protein microarrays based on glycidyl methacrylate-modified polyethylene terephthalate plastic substrate.
    Liu Y; Li CM; Hu W; Lu Z
    Talanta; 2009 Jan; 77(3):1165-71. PubMed ID: 19064107
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of an open stand-alone platform for regenerable automated microarrays.
    Kloth K; Niessner R; Seidel M
    Biosens Bioelectron; 2009 Mar; 24(7):2106-12. PubMed ID: 19110413
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dividable membrane with multi-reaction wells for microarray biochips.
    Chang YJ; Hu CY; Yin LT; Chang CH; Su HJ
    J Biosci Bioeng; 2008 Jul; 106(1):59-64. PubMed ID: 18691532
    [TBL] [Abstract][Full Text] [Related]  

  • 18. User configurable microfluidic device for multiplexed immunoassays based on DNA-directed assembly.
    Schroeder H; Adler M; Gerigk K; Müller-Chorus B; Götz F; Niemeyer CM
    Anal Chem; 2009 Feb; 81(3):1275-9. PubMed ID: 19123774
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Integrated microfluidic bioprocessor for solid phase capture immunoassays.
    Kim J; Jensen EC; Megens M; Boser B; Mathies RA
    Lab Chip; 2011 Sep; 11(18):3106-12. PubMed ID: 21804972
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Microfluidic immunosensor systems.
    Bange A; Halsall HB; Heineman WR
    Biosens Bioelectron; 2005 Jun; 20(12):2488-503. PubMed ID: 15854821
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 39.