BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

618 related articles for article (PubMed ID: 19347971)

  • 21. A longitudinal study of ammonia, acetone and propanol in the exhaled breath of 30 subjects using selected ion flow tube mass spectrometry, SIFT-MS.
    Turner C; Spanel P; Smith D
    Physiol Meas; 2006 Apr; 27(4):321-37. PubMed ID: 16537976
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Ambient analysis of trace compounds in gaseous media by SIFT-MS.
    Smith D; Spaněl P
    Analyst; 2011 May; 136(10):2009-32. PubMed ID: 21431189
    [TBL] [Abstract][Full Text] [Related]  

  • 23. A selected ion flow tube mass spectrometry study of ammonia in mouth- and nose-exhaled breath and in the oral cavity.
    Smith D; Wang T; Pysanenko A; Spanel P
    Rapid Commun Mass Spectrom; 2008; 22(6):783-9. PubMed ID: 18275096
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Selected ion flow tube mass spectrometry for on-line trace gas analysis in biology and medicine.
    Spanĕl P; Smith D
    Eur J Mass Spectrom (Chichester); 2007; 13(1):77-82. PubMed ID: 17878543
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Coordinated FA-MS and SIFT-MS analyses of breath following ingestion of D2O and ethanol: total body water, dispersal kinetics and ethanol metabolism.
    Spanel P; Wang T; Smith D
    Physiol Meas; 2005 Aug; 26(4):447-57. PubMed ID: 15886440
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Concentrations of some metabolites in the breath of healthy children aged 7-18 years measured using selected ion flow tube mass spectrometry (SIFT-MS).
    Enderby B; Lenney W; Brady M; Emmett C; Spaněl P; Smith D
    J Breath Res; 2009 Sep; 3(3):036001. PubMed ID: 21383465
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Quantification of methyl thiocyanate in the headspace of Pseudomonas aeruginosa cultures and in the breath of cystic fibrosis patients by selected ion flow tube mass spectrometry.
    Shestivska V; Nemec A; Dřevínek P; Sovová K; Dryahina K; Spaněl P
    Rapid Commun Mass Spectrom; 2011 Sep; 25(17):2459-67. PubMed ID: 21818806
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Can volatile compounds in exhaled breath be used to monitor control in diabetes mellitus?
    Smith D; Spaněl P; Fryer AA; Hanna F; Ferns GA
    J Breath Res; 2011 Jun; 5(2):022001. PubMed ID: 21512208
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Selected ion flow tube mass spectrometry of exhaled breath condensate headspace.
    Cáp P; Dryahina K; Pehal F; Spanel P
    Rapid Commun Mass Spectrom; 2008 Sep; 22(18):2844-50. PubMed ID: 18712707
    [TBL] [Abstract][Full Text] [Related]  

  • 30. An exploratory comparative study of volatile compounds in exhaled breath and emitted by skin using selected ion flow tube mass spectrometry.
    Turner C; Parekh B; Walton C; Spanel P; Smith D; Evans M
    Rapid Commun Mass Spectrom; 2008; 22(4):526-32. PubMed ID: 18215004
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Reactions of the selected ion flow tube mass spectrometry reagent ions H3O(+) and NO(+) with a series of volatile aldehydes of biogenic significance.
    Smith D; Chippendale TW; Španěl P
    Rapid Commun Mass Spectrom; 2014 Sep; 28(17):1917-28. PubMed ID: 25088135
    [TBL] [Abstract][Full Text] [Related]  

  • 32. The reactions of H(3)O(+), NO(+) and O(2) (+) with several flavourant esters studied using selected ion flow tube mass spectrometry.
    Iachetta L; Malek L; Ross BM
    Rapid Commun Mass Spectrom; 2010 Mar; 24(6):815-22. PubMed ID: 20187085
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Measurement of breath acetone concentrations by selected ion flow tube mass spectrometry in type 2 diabetes.
    Storer M; Dummer J; Lunt H; Scotter J; McCartin F; Cook J; Swanney M; Kendall D; Logan F; Epton M
    J Breath Res; 2011 Dec; 5(4):046011. PubMed ID: 22134047
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Selected ion flow tube study of the reactions of H
    Španěl P; Žabka J; Zymak I; Smith D
    Rapid Commun Mass Spectrom; 2017 Mar; 31(5):437-446. PubMed ID: 27983765
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Selected ion flow tube studies of the reactions of H3O+, NO+ and O2+ with the anaesthetic gases halothane, isoflurane and sevoflurane.
    Wang T; Smith D; Spanĕl P
    Rapid Commun Mass Spectrom; 2002; 16(19):1860-70. PubMed ID: 12271451
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Selected Ion Flow-Drift Tube Mass Spectrometry: Quantification of Volatile Compounds in Air and Breath.
    Spesyvyi A; Smith D; Španěl P
    Anal Chem; 2015 Dec; 87(24):12151-60. PubMed ID: 26583448
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Generation of volatile compounds on mouth exposure to urea and sucrose: implications for exhaled breath analysis.
    Spanĕl P; Turner C; Wang T; Bloor R; Smith D
    Physiol Meas; 2006 Feb; 27(2):N7-17. PubMed ID: 16400196
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A preliminary investigation of exhaled breath from patients with celiac disease using selected ion flow tube mass spectrometry.
    Hryniuk A; Ross BM
    J Gastrointestin Liver Dis; 2010 Mar; 19(1):15-20. PubMed ID: 20361069
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quantification of breath isoprene using the selected ion flow tube mass spectrometric analytical method.
    Spanel P; Davies S; Smith D
    Rapid Commun Mass Spectrom; 1999; 13(17):1733-8. PubMed ID: 10455242
    [TBL] [Abstract][Full Text] [Related]  

  • 40. On-line determination of the deuterium abundance in breath water vapour by flowing afterglow mass spectrometry with applications to measurements of total body water.
    Smith D; Spanel P
    Rapid Commun Mass Spectrom; 2001; 15(1):25-32. PubMed ID: 11135421
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 31.