These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

195 related articles for article (PubMed ID: 19350250)

  • 41. [Radiation exposure of the staff during standardised radiography of dogs and cats].
    Seifert H; Lüpke M; Niehaus H; Meyer-Lindenberg A
    Berl Munch Tierarztl Wochenschr; 2008; 121(5-6):228-38. PubMed ID: 18557527
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Occupational exposure during endovascular aneurysm repair (EVAR) and aortoiliac percutaneous transluminal angioplasty (PTA) procedures.
    Tzanis E; Tsetis D; Kehagias E; Ioannou CV; Damilakis J
    Radiol Med; 2019 Jun; 124(6):539-545. PubMed ID: 30673929
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Patient and staff doses in interventional neuroradiology.
    Bor D; Cekirge S; Türkay T; Turan O; Gülay M; Onal E; Cil B
    Radiat Prot Dosimetry; 2005; 117(1-3):62-8. PubMed ID: 16461524
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Radiation exposure during radiofrequency catheter ablation for atrial fibrillation.
    Macle L; Weerasooriya R; Jais P; Scavee C; Raybaud F; Choi KJ; Hocini M; Clementy J; Haissaguerre M
    Pacing Clin Electrophysiol; 2003 Jan; 26(1P2):288-91. PubMed ID: 12687830
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Radiation protection in radiosynovectomy of the knee.
    Liepe K; Andreeff M; Wunderlich G; Kotzerke J
    Health Phys; 2005 Aug; 89(2):151-4. PubMed ID: 16010126
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Eye lens dose of medical personnel involved in fluoroscopy and interventional procedures at a Malaysian Hospital.
    Wong JHD; Anem LEA; Tan S; Tan SK; Ng KH
    Phys Med; 2019 Dec; 68():47-51. PubMed ID: 31739145
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Measurement of Hp(10), Hp(3) and Hp(0.07) to medical staff in endoscopic retrograde cholangiopancreatography, using thermoluminescence dosimetry.
    ZarifSanayei A; Sina S
    Radiat Prot Dosimetry; 2024 Apr; 200(5):473-480. PubMed ID: 38324516
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Safety considerations during transapical aortic valve implantation.
    Drews T; Pasic M; Juran R; Unbehaun A; Dreysse S; Kukucka M; Mladenow A; Hetzer R; Buz S
    Interact Cardiovasc Thorac Surg; 2014 May; 18(5):574-9. PubMed ID: 24525856
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Senior interventional cardiologists are exposed to higher effective doses than other staff members.
    Ghany HAA; Diab HM; Salah A; Taha AA
    Radiat Environ Biophys; 2020 Nov; 59(4):743-748. PubMed ID: 32676700
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Radiation exposure to the surgeon during percutaneous endoscopic lumbar discectomy: a prospective study.
    Ahn Y; Kim CH; Lee JH; Lee SH; Kim JS
    Spine (Phila Pa 1976); 2013 Apr; 38(7):617-25. PubMed ID: 23026867
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Radiation exposure to eye lens and operator hands during endovascular procedures in hybrid operating rooms.
    Attigah N; Oikonomou K; Hinz U; Knoch T; Demirel S; Verhoeven E; Böckler D
    J Vasc Surg; 2016 Jan; 63(1):198-203. PubMed ID: 26474506
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Technologist radiation exposure in routine clinical practice with 18F-FDG PET.
    Guillet B; Quentin P; Waultier S; Bourrelly M; Pisano P; Mundler O
    J Nucl Med Technol; 2005 Sep; 33(3):175-9. PubMed ID: 16145226
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Occupational exposure to physicians working with a Zero-Gravity™ protection system in haemodynamic and electrophysiology labs and the assessment of its performance against a standard ceiling suspended shield.
    Domienik-Andrzejewska J; Mirowski M; Jastrzębski M; Górnik T; Masiarek K; Warchoł I; Grabowicz W
    Radiat Environ Biophys; 2022 May; 61(2):293-300. PubMed ID: 35218403
    [TBL] [Abstract][Full Text] [Related]  

  • 54. The dose-area product and assessment of the occupational dose in interventional radiology.
    Servomaa A; Karppinen J
    Radiat Prot Dosimetry; 2001; 96(1-3):235-6. PubMed ID: 11586738
    [TBL] [Abstract][Full Text] [Related]  

  • 55. [Exposure of personnel in interventional radiology].
    Meier N; Lenzen H; Sudhoff A; Fiebich M; Kötter L
    Radiologe; 1995 Mar; 35(3):152-5. PubMed ID: 7761590
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Radiation exposure for medical staff performing quantitative coronary perfusion PET with 13N-ammonia.
    Kristoffersen US; Gutte H; Skovgaard D; Andersen PA; Kjaer A
    Radiat Prot Dosimetry; 2010 Feb; 138(2):107-10. PubMed ID: 19801567
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Staff eye doses in a large medical centre in Saudi Arabia: are they meeting the new ICRP recommendations?
    Al-Haj AN; Lobriguito AM; Al-Gain I
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):294-8. PubMed ID: 25848104
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring.
    Sailer AM; Vergoossen L; Paulis L; van Zwam WH; Das M; Wildberger JE; Jeukens CRLPN
    Cardiovasc Intervent Radiol; 2017 Nov; 40(11):1756-1762. PubMed ID: 28500459
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Radiation eye dose to medical staff during respiratory endoscopy under X-ray fluoroscopy.
    Haga Y; Chida K; Kimura Y; Yamanda S; Sota M; Abe M; Kaga Y; Meguro T; Zuguchi M
    J Radiat Res; 2020 Sep; 61(5):691-696. PubMed ID: 32657327
    [TBL] [Abstract][Full Text] [Related]  

  • 60. [Estimation of operator dose by dose area product meter].
    Sakamoto H; Kobayashi H; Ikegawa H; Ohshima S; Aikawa Y; Sano Y; Araki T
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2006 Jul; 62(7):951-60. PubMed ID: 16874284
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.