These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 1935161)

  • 1. Comparison of oxygen consumption measurements: indirect calorimetry versus the reversed Fick method.
    Smithies MN; Royston B; Makita K; Konieczko K; Nunn JF
    Crit Care Med; 1991 Nov; 19(11):1401-6. PubMed ID: 1935161
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Spirometric versus Fick-derived oxygen consumption: which method is better?
    Thrush DN
    Crit Care Med; 1996 Jan; 24(1):91-5. PubMed ID: 8565545
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A comparison between the Fick method and indirect calorimetry for determining oxygen consumption in patients with fulminant hepatic failure.
    Walsh TS; Hopton P; Lee A
    Crit Care Med; 1998 Jul; 26(7):1200-7. PubMed ID: 9671369
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Real-time gas-exchange measurement of oxygen consumption in neonates and infants after cardiac surgery.
    Chang AC; Kulik TJ; Hickey PR; Wessel DL
    Crit Care Med; 1993 Sep; 21(9):1369-75. PubMed ID: 8370302
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Calculated versus measured oxygen consumption during aortic surgery: reliability of the Fick method.
    Pestaña D; Garcia-de-Lorenzo A
    Anesth Analg; 1994 Feb; 78(2):253-6. PubMed ID: 8311276
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calculated versus measured oxygen consumption during and after cardiac surgery. Is it possible to estimate lung oxygen consumption?
    Keinänen O; Takala J
    Acta Anaesthesiol Scand; 1997 Aug; 41(7):803-9. PubMed ID: 9265920
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Oxygen consumption after cardiopulmonary bypass--implications of different measuring methods.
    Oudemans-van Straaten HM; Scheffer GJ; Eysman L; Wildevuur CR
    Intensive Care Med; 1993; 19(2):105-10. PubMed ID: 8486864
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Continuous measurement of oxygen consumption using the reversed fick method.
    Fukui M; Imoto M; Shime N; Hatanaka T; Tojo H
    J Anesth; 1997 Mar; 11(1):27-31. PubMed ID: 28921266
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Oxygen Fick and modified carbon dioxide Fick cardiac outputs.
    Mahutte CK; Jaffe MB; Chen PA; Sasse SA; Wong DH; Sassoon CS
    Crit Care Med; 1994 Jan; 22(1):86-95. PubMed ID: 8124981
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Measured pulmonary oxygen consumption: difference between systemic oxygen uptake measured by the reverse Fick method and indirect calorimetry in cardiac surgery.
    Peyton PJ; Robinson GJ
    Anaesthesia; 2005 Feb; 60(2):146-50. PubMed ID: 15644011
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Inverse fick's principle in comparison to measurements of oxygen consumption in respiratory gases. Does intrapulmonary oxygen uptake account for differences shown by different system methods?].
    Weyland A; Weyland W; Sydow M; Weyland C; Kettler D
    Anaesthesist; 1994 Oct; 43(10):658-66. PubMed ID: 7818047
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Oxygen consumption calculated from the Fick equation has limited utility.
    Stock MC; Ryan ME
    Crit Care Med; 1996 Jan; 24(1):86-90. PubMed ID: 8565544
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of methods of measurements of oxygen consumption in mechanically ventilated patients with multiple trauma: the Fick method versus indirect calorimetry.
    Epstein CD; Peerless JR; Martin JE; Malangoni MA
    Crit Care Med; 2000 May; 28(5):1363-9. PubMed ID: 10834679
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison between oxygen consumption calculated by Fick's principle using a continuous thermodilution technique and measured by indirect calorimetry.
    Bizouarn P; Blanloeil Y; Pinaud M
    Br J Anaesth; 1995 Dec; 75(6):719-23. PubMed ID: 8672320
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Perioperative estimations of oxygen consumption from LiDCO™plus-derived cardiac output and Ca-cvO2 difference: Relationship with measurements by indirect calorimetry in elderly patients undergoing major abdominal surgery.
    Jakobsson J; Norén C; Hagel E; Backheden M; Kalman S; Bartha E
    PLoS One; 2024; 19(7):e0272239. PubMed ID: 39052563
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Calculation is unsuitable for determination of O2-consumption (VO2) in case of O2-supply-dependency.
    Kemming GI; Meisner FG; Kleen M; Habler OP
    Eur J Med Res; 2002 Apr; 7(4):139-48. PubMed ID: 12010648
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Calculated and measured oxygen consumption in mechanically ventilated surgical patients in the early post-operative period.
    Brandi LS; Bertolini R; Santini L
    Eur J Anaesthesiol; 1999 Jan; 16(1):53-61. PubMed ID: 10084102
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of oxygen consumption calculated by Fick's principle (using a central venous catheter) and measured by indirect calorimetry.
    Inadomi C; Terao Y; Yamashita K; Fukusaki M; Takada M; Sumikawa K
    J Anesth; 2008; 22(2):163-6. PubMed ID: 18500614
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Indirect Calorimetry Overestimates Oxygen Consumption in Young Children: Caution is Advised Using Direct Fick Method as a Reference Method in Cardiac Output Comparison Studies.
    Sigurdsson TS; Lindberg L
    Pediatr Cardiol; 2020 Jan; 41(1):149-154. PubMed ID: 31741015
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Continuous measurement of cardiac output by the Fick principle: clinical validation in intensive care.
    Keinänen O; Takala J; Kari A
    Crit Care Med; 1992 Mar; 20(3):360-5. PubMed ID: 1541096
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.