These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

191 related articles for article (PubMed ID: 19353776)

  • 1. Dual-energy X-ray absorptiometry is the method of choice to assess body composition in COPD.
    Miller A; Strauss BJ; Mol S; Kyoong A; Holmes PH; Finlay P; Bardin PG; Guy P
    Respirology; 2009 Apr; 14(3):411-8. PubMed ID: 19353776
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Comparative analysis of body composition assessment methods in healthy men and in chronic obstructive pulmonary disease patients: anthropometry, bioelectrical impedance and dual-energy X-ray absorptiometry].
    Freitas Júnior IF; Rupp de Paiva SA; de Godoy I; Smaili Santos SM; Campana AO
    Arch Latinoam Nutr; 2005 Jun; 55(2):124-31. PubMed ID: 16335221
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Critical view on diagnosing muscle wasting by single-frequency bio-electrical impedance in COPD.
    Rutten EP; Spruit MA; Wouters EF
    Respir Med; 2010 Jan; 104(1):91-8. PubMed ID: 19646856
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of dual-energy X-ray absorptiometry to four other methods to determine body composition in underweight patients with chronic gastrointestinal disease.
    Haderslev KV; Staun M
    Metabolism; 2000 Mar; 49(3):360-6. PubMed ID: 10726915
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Skinfold anthropometry--the accurate method for fat free mass measurement in COPD.
    Hronek M; Kovarik M; Aimova P; Koblizek V; Pavlikova L; Salajka F; Zadak Z
    COPD; 2013 Oct; 10(5):597-603. PubMed ID: 23844827
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Body composition in renal transplant patients: bioimpedance analysis compared to isotope dilution, dual energy X-ray absorptiometry, and anthropometry.
    van den Ham EC; Kooman JP; Christiaans MH; Nieman FH; Van Kreel BK; Heidendal GA; Van Hooff JP
    J Am Soc Nephrol; 1999 May; 10(5):1067-79. PubMed ID: 10232694
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Body composition in patients with chronic obstructive pulmonary disease: which method to use in clinical practice?
    Lerario MC; Sachs A; Lazaretti-Castro M; Saraiva LG; Jardim JR
    Br J Nutr; 2006 Jul; 96(1):86-92. PubMed ID: 16869995
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Bedside methods versus dual energy X-ray absorptiometry for body composition measurement in COPD.
    Steiner MC; Barton RL; Singh SJ; Morgan MD
    Eur Respir J; 2002 Apr; 19(4):626-31. PubMed ID: 11998990
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Total body dual X-ray absorptiometry is a good measure of both fat mass and fat-free mass in liver cirrhosis compared to "gold-standard" techniques. Melbourne Liver Group.
    Strauss BJ; Gibson PR; Stroud DB; Borovnicar DJ; Xiong DW; Keogh J
    Ann N Y Acad Sci; 2000 May; 904():55-62. PubMed ID: 10865710
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Body Composition Measurement in Bronchiectasis: Comparison between Bioelectrical Impedance Analysis, Skinfold Thickness Measurement, and Dual-Energy X-ray Absorptiometry before and after Pulmonary Rehabilitation.
    Doña E; Olveira C; Palenque FJ; Porras N; Dorado A; Martín-Valero R; Godoy AM; Espíldora F; Contreras V; Olveira G
    J Acad Nutr Diet; 2018 Aug; 118(8):1464-1473. PubMed ID: 29656933
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Measurement of body composition in chronic renal failure: comparison of skinfold anthropometry and bioelectrical impedance with dual energy X-ray absorptiometry.
    Woodrow G; Oldroyd B; Smith MA; Turney JH
    Eur J Clin Nutr; 1996 May; 50(5):295-301. PubMed ID: 8735310
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validity of bioelectrical impedance analysis in estimation of fat-free mass in colorectal cancer patients.
    Ræder H; Kværner AS; Henriksen C; Florholmen G; Henriksen HB; Bøhn SK; Paur I; Smeland S; Blomhoff R
    Clin Nutr; 2018 Feb; 37(1):292-300. PubMed ID: 28122662
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Estimation of body composition from bioelectrical impedance of body segments: comparison with dual-energy X-ray absorptiometry.
    Stewart SP; Bramley PN; Heighton R; Green JH; Horsman A; Losowsky MS; Smith MA
    Br J Nutr; 1993 May; 69(3):645-55. PubMed ID: 8329341
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Body composition assessment in adults with cystic fibrosis: comparison of dual-energy X-ray absorptiometry with skinfolds and bioelectrical impedance analysis.
    King S; Wilson J; Kotsimbos T; Bailey M; Nyulasi I
    Nutrition; 2005; 21(11-12):1087-94. PubMed ID: 16183254
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of body composition analysis methods in clinical routine.
    Erselcan T; Candan F; Saruhan S; Ayca T
    Ann Nutr Metab; 2000; 44(5-6):243-8. PubMed ID: 11146331
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of two bioelectrical impedance devices and dual-energy X-ray absorptiometry to evaluate body composition in heart failure.
    Alves FD; Souza GC; Biolo A; Clausell N
    J Hum Nutr Diet; 2014 Dec; 27(6):632-8. PubMed ID: 24684316
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Body composition in prepubertal girls: comparison of six methods.
    Treuth MS; Butte NF; Wong WW; Ellis KJ
    Int J Obes Relat Metab Disord; 2001 Sep; 25(9):1352-9. PubMed ID: 11571599
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of fluid status on techniques used to assess body composition in peritoneal dialysis patients.
    Konings CJ; Kooman JP; Schonck M; van Kreel B; Heidendal GA; Cheriex EC; van der Sande FM; Leunissen KM
    Perit Dial Int; 2003; 23(2):184-90. PubMed ID: 12713087
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of a bioelectrical impedance analysis system for body composition assessment in patients with COPD.
    Fonseca FR; Karloh M; Araujo CLP; Reis CMD; Mayer AF
    J Bras Pneumol; 2018; 44(4):315-320. PubMed ID: 30328930
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Body composition in patients with short bowel syndrome: an assessment by bioelectric impedance spectroscopy (BIS) and dual-energy absorptiometry (DXA).
    Carlsson E; Bosaeus I; Nordgren S
    Eur J Clin Nutr; 2004 Jun; 58(6):853-9. PubMed ID: 15164105
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.