BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 19354030)

  • 1. Examination of body fluids: evaluating gross appearance; performing cell counts.
    Collins L
    Clin Lab Sci; 2009; 22(1):46-8. PubMed ID: 19354030
    [No Abstract]   [Full Text] [Related]  

  • 2. Use of the Advia 120 hematology analyzer in the differential cytologic analysis of biological fluids (cerebrospinal, peritoneal, pleural, pericardial, synovial, and others).
    Aulesa C; Mainar I; Prieto M; Cobos N; Galimany R
    Lab Hematol; 2003; 9(4):214-24. PubMed ID: 14649464
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of body fluid analysis on the Coulter LH 750.
    Brown W; Keeney M; Chin-Yee I; Johnson K; Lantis K; Finn W; Wolfe N; Kaplan S
    Lab Hematol; 2003; 9(3):155-9. PubMed ID: 14521323
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Examination of body fluids.
    Feldman BF; Ruehl WW
    Mod Vet Pract; 1984 Apr; 65(4):295-8. PubMed ID: 6738496
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Rapid method of cytological studies of cerebrospinal fluid and other oligocellular systemic fluids].
    Pakszys W
    Pol Tyg Lek; 1973 May; 28(17):607-9. PubMed ID: 4712329
    [No Abstract]   [Full Text] [Related]  

  • 6. Hematology analyzers and body fluid analysis.
    Rabinovitch A
    Am J Clin Pathol; 2010 Jul; 134(1):167-8. PubMed ID: 20551281
    [No Abstract]   [Full Text] [Related]  

  • 7. Comparative evaluation of the Iris iQ200 body fluid module with manual hemacytometer count.
    Walker TJ; Nelson LD; Dunphy BW; Anderson DM; Kickler TS
    Am J Clin Pathol; 2009 Mar; 131(3):333-8. PubMed ID: 19228639
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Evaluation of capability of cell count and detection of tumor cells in cerebrospinal and body fluids by automated hematology analyzer].
    Takemura H; Tabe Y; Ishii K; Kobayashi Y; Kuno Y; Horii T; Miyake K; Miida T; Ohsaka A
    Rinsho Byori; 2010 Jun; 58(6):559-64. PubMed ID: 20662266
    [TBL] [Abstract][Full Text] [Related]  

  • 9. An evaluation of the cell-dyn 3200 for counting cells in cerebrospinal and other body fluids.
    Andrews J; Setran E; McDonnel L; Kussick S; Wood BL; Sabath DE
    Lab Hematol; 2005; 11(2):98-106. PubMed ID: 16024333
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Revision of a method for performance of total and differential cell counts in cerebrospinal and serous fluid.
    Lewis JF; Delvaux TC
    Am J Med Technol; 1967; 33(4):336. PubMed ID: 6058730
    [No Abstract]   [Full Text] [Related]  

  • 11. [Cytological examinations].
    Inagaki S
    Rinsho Byori; 1998 Mar; Suppl 107():154-60. PubMed ID: 9569755
    [No Abstract]   [Full Text] [Related]  

  • 12. A multicenter evaluation of the Iris iQ200 automated urine microscopy analyzer body fluids module and comparison with hemacytometer cell counts.
    Butch AW; Wises PK; Wah DT; Gornet TG; Fritsche HA
    Am J Clin Pathol; 2008 Mar; 129(3):445-50. PubMed ID: 18285268
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A simplified method for the cytologic study of body fluids.
    Tang TT; McCreadie SR
    Am J Clin Pathol; 1973 Jan; 59(1):113-6. PubMed ID: 4688555
    [No Abstract]   [Full Text] [Related]  

  • 14. Cholesterol crystals causing falsely elevated automated cell count.
    Shen PU; Blair JL
    Am J Clin Pathol; 2006 Mar; 125(3):358-63. PubMed ID: 16613338
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Miscellaneous findings in body fluids.
    Collins L
    Clin Lab Sci; 2009; 22(1):54-5. PubMed ID: 19354032
    [No Abstract]   [Full Text] [Related]  

  • 16. Lack of harmonization in high fluorescent cell automated counts with body fluids mode in ascitic, pleural, synovial, and cerebrospinal fluids.
    Buoro S; Seghezzi M; Dominoni P; Moioli V; Manenti B; Previtali G; Ottomano C; Lippi G
    Int J Lab Hematol; 2019 Apr; 41(2):277-286. PubMed ID: 30758900
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automated morphological analysis of cells in body fluids by the digital microscopy system DM96.
    Riedl JA; Dinkelaar RB; van Gelder W
    J Clin Pathol; 2010 Jun; 63(6):538-43. PubMed ID: 20498027
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The clinical reliability of automated cerebrospinal fluid cell counts on the Beckman-Coulter LH750 and Iris iQ200.
    Glasser L; Murphy CA; Machan JT
    Am J Clin Pathol; 2009 Jan; 131(1):58-63. PubMed ID: 19095566
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Body fluid cell counts by automated methods.
    Sandhaus LM
    Clin Lab Med; 2015 Mar; 35(1):93-103. PubMed ID: 25676374
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Performance of the Iris iQ(R)200 Elite analyser in the cell counting of serous effusion fluids and cerebrospinal drainage fluids.
    Goubard A; Marzouk M; Canoui-Poitrine F; Launay S; Le Thuaut A; Legrand P
    J Clin Pathol; 2011 Dec; 64(12):1123-7. PubMed ID: 21836038
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.