BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

153 related articles for article (PubMed ID: 19356420)

  • 1. A randomized cross-over study for evaluation of the effect of image optimization with contrast on the diagnostic accuracy of dobutamine echocardiography in coronary artery disease The OPTIMIZE Trial.
    Plana JC; Mikati IA; Dokainish H; Lakkis N; Abukhalil J; Davis R; Hetzell BC; Zoghbi WA
    JACC Cardiovasc Imaging; 2008 Mar; 1(2):145-52. PubMed ID: 19356420
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The value of contrast dobutamine stress echocardiography on detecting coronary artery disease in overweight and obese patients.
    Hu SJ; Liu SX; Katus HA; Luedde M
    Can J Cardiol; 2007 Sep; 23(11):885-9. PubMed ID: 17876380
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dobutamine stress echocardiography: improved endocardial border definition and wall motion analysis with tissue harmonic imaging.
    Zaglavara T; Norton M; Cumberledge B; Morris D; Irvine T; Cummins C; Schuster J; Kenny A
    J Am Soc Echocardiogr; 1999 Sep; 12(9):706-13. PubMed ID: 10477414
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Echocardiography contrast for image optimization: beyond confidence, it is a matter of accuracy.
    Pellikka PA; Mulvagh SL
    JACC Cardiovasc Imaging; 2008 Mar; 1(2):153-5. PubMed ID: 19356421
    [No Abstract]   [Full Text] [Related]  

  • 5. Detection of subendocardial ischemia in the left anterior descending coronary artery territory with real-time myocardial contrast echocardiography during dobutamine stress echocardiography.
    Xie F; Dodla S; O'Leary E; Porter TR
    JACC Cardiovasc Imaging; 2008 May; 1(3):271-8. PubMed ID: 19356438
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of intravenous contrast for left ventricular opacification and border definition on sensitivity and specificity of dobutamine stress echocardiography compared with coronary angiography in technically difficult patients.
    Dolan MS; Riad K; El-Shafei A; Puri S; Tamirisa K; Bierig M; St Vrain J; McKinney L; Havens E; Habermehl K; Pyatt L; Kern M; Labovitz AJ
    Am Heart J; 2001 Nov; 142(5):908-15. PubMed ID: 11685180
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Transpulmonary contrast echocardiography: effects on delineation of endocardial border, assessment of wall motion and interobserver variability in stress echocardiograms of limited image quality.
    Schnaack SD; Siegmund P; Spes CH; Tammen AR; Theisen K; Angermann CE
    Coron Artery Dis; 2000 Oct; 11(7):549-54. PubMed ID: 11023243
    [TBL] [Abstract][Full Text] [Related]  

  • 8. [Improved endocardial border delineation during dobutamine stress echocardiography using the left heart contrast medium BY 963].
    Frieske R; Kühl H; Yuan D; Lepper W; Franke A; Hoffmann R
    Z Kardiol; 2000 Mar; 89(3):186-94. PubMed ID: 10798274
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Two-Dimensional Speckle-Tracking during Dobutamine Stress Echocardiography in the Detection of Myocardial Ischemia in Patients with Suspected Coronary Artery Disease.
    Uusitalo V; Luotolahti M; Pietilä M; Wendelin-Saarenhovi M; Hartiala J; Saraste M; Knuuti J; Saraste A
    J Am Soc Echocardiogr; 2016 May; 29(5):470-479.e3. PubMed ID: 26852941
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Hyperemic Impedance Echocardiography with Dobutamine Stress Echocardiography to Detect Inducible Myocardial Ischemia: A Pilot Study.
    Patel JJ; Gupta A; Nanda NC
    Echocardiography; 2016 Mar; 33(3):416-20. PubMed ID: 26932721
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of left ventricular wall motion and delineation of the endocardial border after intravenous injection of Infoson during dobutamine stress echocardiography.
    Ikonomidis I; Holmes E; Narbuvold H; Bolstad B; Muan B; Nihoyannopoulos P
    Coron Artery Dis; 1998; 9(9):567-76. PubMed ID: 9861518
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Does second harmonic imaging improve left ventricular endocardial border identification at higher heart rates during dobutamine stress echocardiography?
    Sozzi FB; Poldermans D; Boersma E; Elhendy A; Bax JJ; Borghetti A; Roelandt JR
    J Am Soc Echocardiogr; 2000 Nov; 13(11):1019-24. PubMed ID: 11093104
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of contrast-enhanced real-time live 3-dimensional dobutamine stress echocardiography with contrast 2-dimensional echocardiography for detecting stress-induced wall-motion abnormalities.
    Takeuchi M; Otani S; Weinert L; Spencer KT; Lang RM
    J Am Soc Echocardiogr; 2006 Mar; 19(3):294-9. PubMed ID: 16500492
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Contrast dobutamine stress echocardiography: clinical practice assessment in 300 consecutive patients.
    Rainbird AJ; Mulvagh SL; Oh JK; McCully RB; Klarich KW; Shub C; Mahoney DW; Pellikka PA
    J Am Soc Echocardiogr; 2001 May; 14(5):378-85. PubMed ID: 11337683
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The validation of fractional flow reserve in patients with coronary multivessel disease: a comparison with SPECT and contrast-enhanced dobutamine stress echocardiography.
    Erhard I; Rieber J; Jung P; Hacker M; Schiele T; Stempfle HU; König A; Baylacher M; Theisen K; Siebert U; Klauss V
    Z Kardiol; 2005 May; 94(5):321-7. PubMed ID: 15868360
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improvement of endocardial border delineation during dobutamine stress echocardiography with Levovist.
    Sakakura K; Tone K; Kakimoto H; Koyama M; Sekioka K
    J Cardiol; 2003 Jun; 41(6):277-83. PubMed ID: 12861961
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of contrast application on interpretability and diagnostic value of dobutamine stress echocardiography in patients with intermediate coronary lesions: comparison with myocardial fractional flow reserve.
    Jung PH; Rieber J; Störk S; Hoyer C; Erhardt I; Nowotny A; Voelker W; Weidemann F; Ertl G; Klauss V; Angermann CE
    Eur Heart J; 2008 Oct; 29(20):2536-43. PubMed ID: 18499651
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Layer-specific analysis of dobutamine stress echocardiography for the evaluation of coronary artery disease.
    Park JH; Woo JS; Ju S; Jung SW; Lee I; Kim JB; Kim SJ; Kim W; Kim WS; Kim KS
    Medicine (Baltimore); 2016 Aug; 95(32):e4549. PubMed ID: 27512879
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Native tissue second harmonic imaging improves endocardial and epicardial border definition in dobutamine stress echocardiography.
    Nixdorff U; Matschke C; Winklmaier M; Flachskampf FA; Ludwig J; Pohle K; Land M; Gefeller O; Daniel WG
    Eur J Echocardiogr; 2001 Mar; 2(1):52-61. PubMed ID: 11882426
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Frequency, Predictors, and Implications of Abnormal Blood Pressure Responses During Dobutamine Stress Echocardiography.
    Abram S; Arruda-Olson AM; Scott CG; Pellikka PA; Nkomo VT; Oh JK; Milan A; Abidian MM; McCully RB
    Circ Cardiovasc Imaging; 2017 Apr; 10(4):. PubMed ID: 28351907
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.