These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
185 related articles for article (PubMed ID: 19362033)
1. Treatment of complex proximal interphalangeal joint fractures using a new dynamic external fixator: 15 cases. Körting O; Facca S; Diaconu M; Liverneaux P Chir Main; 2009 Jun; 28(3):153-7. PubMed ID: 19362033 [TBL] [Abstract][Full Text] [Related]
2. Proximal interphalangeal joint fractures treated with a dynamic external fixator: A multicenter and retrospective study of 88 cases. Pélissier P; Gobel F; Choughri H; Alet JM Chir Main; 2015 Oct; 34(5):245-50. PubMed ID: 26359858 [TBL] [Abstract][Full Text] [Related]
3. Dynamic external fixation for pilon fractures of the interphalangeal joints. Hynes MC; Giddins GE J Hand Surg Br; 2001 Apr; 26(2):122-4. PubMed ID: 11281662 [TBL] [Abstract][Full Text] [Related]
4. Proximal interphalangeal joint fractures of the hand: treatment with an external dynamic traction device. Theivendran K; Pollock J; Rajaratnam V Ann Plast Surg; 2007 Jun; 58(6):625-9. PubMed ID: 17522484 [TBL] [Abstract][Full Text] [Related]
5. A Novel Technique for Dynamic External Fixation of Proximal Interphalangeal Joint Fracture-Dislocations. Sastravaha N; Limudomporn K; Taweewuthisub W J Hand Surg Asian Pac Vol; 2020 Dec; 25(4):427-433. PubMed ID: 33115354 [No Abstract] [Full Text] [Related]
6. A novel dynamic distraction external fixator for proximal interphalangeal joint fracture dislocation. Wang HZ; Zhao JY; Zhang ZS J Int Med Res; 2019 Apr; 47(4):1628-1635. PubMed ID: 30747021 [TBL] [Abstract][Full Text] [Related]
7. A biomechanical analysis of distraction force in modified hynes-Giddins dynamic external fixator. Cheema M; Mangat K; Holbrook N; Rajaratnam V Ann Plast Surg; 2007 Sep; 59(3):300-1. PubMed ID: 17721219 [TBL] [Abstract][Full Text] [Related]
8. Management of intraarticular proximal interphalangeal joint fracture-dislocations and pilon fractures with the Ligamentotaxor® device. Mabvuure NT; Pinto-Lopes R; Sierakowski A Arch Orthop Trauma Surg; 2020 Aug; 140(8):1133-1141. PubMed ID: 32448930 [TBL] [Abstract][Full Text] [Related]
9. Treatment of proximal interphalangeal dorsal fracture-dislocation injuries with dynamic external fixation: a pins and rubber band system. Ellis SJ; Cheng R; Prokopis P; Chetboun A; Wolfe SW; Athanasian EA; Weiland AJ J Hand Surg Am; 2007 Oct; 32(8):1242-50. PubMed ID: 17923310 [TBL] [Abstract][Full Text] [Related]
10. Pyrolytic carbon arthroplasty for posttraumatic arthritis of the proximal interphalangeal joint. Nunley RM; Boyer MI; Goldfarb CA J Hand Surg Am; 2006 Nov; 31(9):1468-74. PubMed ID: 17095375 [TBL] [Abstract][Full Text] [Related]
12. Functional Outcomes Following Pilon Fractures of the Middle Phalanx Managed with the Ligamentotaxor External Fixator. Colegate-Stone T; Marenah K; Compson J; Tahmassebi R; Tavakkolizadeh A Hand Surg; 2015; 20(2):285-9. PubMed ID: 26051770 [TBL] [Abstract][Full Text] [Related]
13. Avoiding pitfalls of the pins and rubbers traction technique for fractures of the proximal interphalangeal joint. Agarwal AK; Karri V; Pickford MA Ann Plast Surg; 2007 May; 58(5):489-95. PubMed ID: 17452831 [TBL] [Abstract][Full Text] [Related]
14. Gradual joint distraction of post-traumatic flexion contracture of the proximal interphalangeal joint by a mini-external fixator. Houshian S; Chikkamuniyappa C; Schroeder H J Bone Joint Surg Br; 2007 Feb; 89(2):206-9. PubMed ID: 17322436 [TBL] [Abstract][Full Text] [Related]
15. [Dynamic external traction system for management of distal displaced fractures of the head of the proximal phalanx]. El Khatib K; Kadlub N; Trost O; Danino AM; Malka G Chir Main; 2007 Feb; 26(1):21-5. PubMed ID: 17418765 [TBL] [Abstract][Full Text] [Related]
16. Distraction arthrolysis using an external fixator and flexor tenolysis for proximal interphalangeal joint extension contracture after severe crush injury. Kawakatsu M; Ishikawa K; Terai T; Saito S J Hand Surg Am; 2010 Sep; 35(9):1457-62. PubMed ID: 20709466 [TBL] [Abstract][Full Text] [Related]
17. The Suzuki frame for complex intra-articular fractures of the proximal interphalangeal joint of the fingers. Keramidas E; Solomos M; Page RE; Miller G Ann Plast Surg; 2007 May; 58(5):484-8. PubMed ID: 17452830 [TBL] [Abstract][Full Text] [Related]
18. Staged external fixation for chronic fracture-dislocation of the proximal interphalangeal joint: outcomes of patients with a minimum 2-year follow-up. Hamada Y; Hibino N; Tonogai I; Konishi T; Satoura M; Yamano M J Hand Surg Am; 2012 Mar; 37(3):434-9. PubMed ID: 22385774 [TBL] [Abstract][Full Text] [Related]
19. The use of a low-profile Ilizarov external fixator in the treatment of complex fractures and non-unions of the distal femur. Cavusoglu AT; Ozsoy MH; Dincel VE; Sakaogullari A; Basarir K; Ugurlu M Acta Orthop Belg; 2009 Apr; 75(2):209-18. PubMed ID: 19492560 [TBL] [Abstract][Full Text] [Related]
20. Dynamic external fixator for pilon fractures of the proximal interphalangeal joints: a simple fixator for a complex fracture. Syed AA; Agarwal M; Boome R J Hand Surg Br; 2003 Apr; 28(2):137-41. PubMed ID: 12631485 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]