These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Characteristics of new composite- and classical potentiometric sensors for the determination of pioglitazone in some pharmaceutical formulations. Mostafa GA; Al-Majed A J Pharm Biomed Anal; 2008 Sep; 48(1):57-61. PubMed ID: 18555633 [TBL] [Abstract][Full Text] [Related]
3. New potentiometric sensors based on selective recognition sites for determination of ephedrine in some pharmaceuticals and biological fluids. Hassan SS; Kamel AH; Abd El-Naby H Talanta; 2013 Jan; 103():330-6. PubMed ID: 23200395 [TBL] [Abstract][Full Text] [Related]
4. Improving the detection limits of antispasmodic drugs electrodes by using modified membrane sensors with inner solid contact. Ibrahim H; Issa YM; Abu-Shawish HM J Pharm Biomed Anal; 2007 May; 44(1):8-15. PubMed ID: 17383844 [TBL] [Abstract][Full Text] [Related]
5. Molecularly imprinted polymer based potentiometric sensor for the determination of hydroxyzine in tablets and biological fluids. Javanbakht M; Fard SE; Mohammadi A; Abdouss M; Ganjali MR; Norouzi P; Safaraliee L Anal Chim Acta; 2008 Mar; 612(1):65-74. PubMed ID: 18331859 [TBL] [Abstract][Full Text] [Related]
6. Potentiometric behaviour of ion selective electrodes based on iron porphyrins: the influence of porphyrin substituents on the response properties and analytical determination of diclofenac in pharmaceutical formulations. Santos EM; Araújo AN; Couto CM; Montenegro MC J Pharm Biomed Anal; 2006 Nov; 42(5):535-42. PubMed ID: 16842960 [TBL] [Abstract][Full Text] [Related]
7. Fabrication of a planar-form screen-printed solid electrolyte modified Ag/AgCl reference electrode for application in a potentiometric biosensor. Liao WY; Chou TC Anal Chem; 2006 Jun; 78(12):4219-23. PubMed ID: 16771553 [TBL] [Abstract][Full Text] [Related]
8. Characterization and determination of poly(vinylpyrrolidone) by complexation with an anionic azo-dye and nonequilibrium capillary electrophoresis. Beneito-Cambra M; Herrero-Martínez JM; Ramis-Ramos G J Chromatogr A; 2009 Dec; 1216(51):9014-21. PubMed ID: 19926094 [TBL] [Abstract][Full Text] [Related]
9. Potentiometric membrane sensors for the selective determination of pyridoxine hydrochloride (vitamin B6) in some pharmaceutical formulations. Mostafa GA; Ghazy Sel-S Ann Chim; 2003; 93(7-8):691-9. PubMed ID: 12940602 [TBL] [Abstract][Full Text] [Related]
10. Conventional and planar chip sensors for potentiometric assay of uric acid in biological fluids using flow injection analysis. Kamel AH J Pharm Biomed Anal; 2007 Oct; 45(2):341-8. PubMed ID: 17604587 [TBL] [Abstract][Full Text] [Related]
11. A novel cobalt(II)-selective potentiometric sensor based on p-(4-n-butylphenylazo)calix[4]arene. Kumar P; Shim YB Talanta; 2009 Jan; 77(3):1057-62. PubMed ID: 19064091 [TBL] [Abstract][Full Text] [Related]
12. Sulfadiazine-potentiometric sensors for flow and batch determinations of sulfadiazine in drugs and biological fluids. Kamel AH; Almeida SA; Sales MG; Moreira FT Anal Sci; 2009 Mar; 25(3):365-71. PubMed ID: 19276592 [TBL] [Abstract][Full Text] [Related]
13. Junction-less reference electrode for potentiometric measurements obtained by buffering pH in a conducting polymer matrix. Blaz T; Migdalski J; Lewenstam A Analyst; 2005 May; 130(5):637-43. PubMed ID: 15852131 [TBL] [Abstract][Full Text] [Related]
14. The use of ion-selective electrodes in the determination of drug substances. Vytras K J Pharm Biomed Anal; 1989; 7(7):789-812. PubMed ID: 2490089 [TBL] [Abstract][Full Text] [Related]
15. Miniaturized ionophore-based potentiometric sensors for the flow-injection determination of metformin in pharmaceutical formulations and biological fluids. Khaled E; Kamel MS; Hassan HN; Abd El-Alim SH; Aboul-Enein HY Analyst; 2012 Dec; 137(23):5680-7. PubMed ID: 23050261 [TBL] [Abstract][Full Text] [Related]
16. Voltammetric analysis of N-containing drugs using the hanging galinstan drop electrode (HGDE). Channaa H; Surmann P Pharmazie; 2009 Mar; 64(3):161-5. PubMed ID: 19348337 [TBL] [Abstract][Full Text] [Related]
17. Ion-selective potentiometry in clinical chemistry. A review. Kruse-Jarres JD Med Prog Technol; 1988; 13(3):107-30. PubMed ID: 3285159 [TBL] [Abstract][Full Text] [Related]
19. Investigation of the role of electrolytes and non-electrolytes on the cloud point and dye solubilization in antidepressant drug imipramine hydrochloride solutions. Alam MS; Kabir-Ud-Din Colloids Surf B Biointerfaces; 2008 Aug; 65(1):74-9. PubMed ID: 18423990 [TBL] [Abstract][Full Text] [Related]
20. [Factors determining the dynamics of changes in the potential of the ion-selective electrode in clinical electrolyte analyzers]. Kriukova VA Med Tekh; 1990; (5):20-2. PubMed ID: 2273965 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]