247 related articles for article (PubMed ID: 19362207)
1. Investigation of voltammetric enzyme-linked immunoassay system based on N-heterocyclic substrate of 2,3-diaminopyridine.
Yu F; Du P; Lei X; Zhang S
Talanta; 2009 Jun; 78(4-5):1395-400. PubMed ID: 19362207
[TBL] [Abstract][Full Text] [Related]
2. Investigation of voltammetric enzyme-linked immunoassay based on a new system of HAP-H2O2-HRP.
Zhang S; Zou J; Yu F
Talanta; 2008 Jun; 76(1):122-7. PubMed ID: 18585252
[TBL] [Abstract][Full Text] [Related]
3. 3,3'-diaminobenzidine (DAB)-H2O2-HRP voltammetric enzyme-linked immunoassay for the detection of carcionembryonic antigen.
Zhang S; Yang J; Lin J
Bioelectrochemistry; 2008 Feb; 72(1):47-52. PubMed ID: 18248855
[TBL] [Abstract][Full Text] [Related]
4. Detection of prostate specific antigen with 3,4-diaminobenzoic acid (DBA)-H(2)O(2)-HRP voltammetric enzyme-linked immunoassay system.
Zhang S; Du P; Li F
Talanta; 2007 Jun; 72(4):1487-93. PubMed ID: 19071788
[TBL] [Abstract][Full Text] [Related]
5. Capillary electrophoresis enzyme immunoassay for alpha-fetoprotein and thyroxine in human serum with electrochemical detection.
Li XM; Zhang F; Zhang SS
J Sep Sci; 2008 Feb; 31(2):336-40. PubMed ID: 18246582
[TBL] [Abstract][Full Text] [Related]
6. CE-based simultaneous liquid-phase noncompetitive enzyme immunoassay for three tumor markers in human serum using electrochemical detection.
Zhang S; Li X; Zhang F
Electrophoresis; 2007 Dec; 28(23):4427-34. PubMed ID: 17979157
[TBL] [Abstract][Full Text] [Related]
7. In situ amplified electrochemical immunoassay for carcinoembryonic antigen using horseradish peroxidase-encapsulated nanogold hollow microspheres as labels.
Tang D; Ren J
Anal Chem; 2008 Nov; 80(21):8064-70. PubMed ID: 18816067
[TBL] [Abstract][Full Text] [Related]
8. Sensitive detection of a plant virus by electrochemical enzyme-linked immunoassay.
Jiao K; Sun W; Zhang SS
Fresenius J Anal Chem; 2000 Aug; 367(7):667-71. PubMed ID: 11221932
[TBL] [Abstract][Full Text] [Related]
9. Detection of TMV with ODA-H(2)O(2)-HRP voltammetric enzyme-linked immunoassay system.
Jiao K; Zhang S; Wei L; Liu C; Zhang C; Zhang Z; Liu J; Wei P
Talanta; 1998 Dec; 47(5):1129-37. PubMed ID: 18967418
[TBL] [Abstract][Full Text] [Related]
10. Detection of ferritin in human serum with a MAP-H(2)O(2)-HRP voltammetric enzyme-linked immunoassay system.
Zhang S; Jiao K; Chen H; Wang M
Talanta; 1999 Aug; 50(1):95-101. PubMed ID: 18967699
[TBL] [Abstract][Full Text] [Related]
11. Prostate-specific antigen detection by using a reusable amperometric immunosensor based on reversible binding and leasing of HRP-anti-PSA from phenylboronic acid modified electrode.
Liu S; Zhang X; Wu Y; Tu Y; He L
Clin Chim Acta; 2008 Sep; 395(1-2):51-6. PubMed ID: 18514069
[TBL] [Abstract][Full Text] [Related]
12. Advent of innovative chemiluminescent enzyme immunoassay.
Lee JH; Rho JE; Rho TH; Newby JG
Biosens Bioelectron; 2010 Oct; 26(2):377-82. PubMed ID: 20739174
[TBL] [Abstract][Full Text] [Related]
13. Ultrasensitive electrochemical immunosensor for clinical immunoassay using thionine-doped magnetic gold nanospheres as labels and horseradish peroxidase as enhancer.
Tang D; Yuan R; Chai Y
Anal Chem; 2008 Mar; 80(5):1582-8. PubMed ID: 18220412
[TBL] [Abstract][Full Text] [Related]
14. Amplified electrochemical detection of a cancer biomarker by enhanced precipitation using horseradish peroxidase attached on carbon nanotubes.
Akter R; Rahman MA; Rhee CK
Anal Chem; 2012 Aug; 84(15):6407-15. PubMed ID: 22793977
[TBL] [Abstract][Full Text] [Related]
15. Bioelectrochemical immunoassay of polychlorinated biphenyl.
Lin YY; Liu G; Wai CM; Lin Y
Anal Chim Acta; 2008 Mar; 612(1):23-8. PubMed ID: 18331854
[TBL] [Abstract][Full Text] [Related]
16. Disposable electrochemical immunosensor diagnosis device based on nanoparticle probe and immunochromatographic strip.
Liu G; Lin YY; Wang J; Wu H; Wai CM; Lin Y
Anal Chem; 2007 Oct; 79(20):7644-53. PubMed ID: 17877418
[TBL] [Abstract][Full Text] [Related]
17. A nanoparticle label/immunochromatographic electrochemical biosensor for rapid and sensitive detection of prostate-specific antigen.
Lin YY; Wang J; Liu G; Wu H; Wai CM; Lin Y
Biosens Bioelectron; 2008 Jun; 23(11):1659-65. PubMed ID: 18406127
[TBL] [Abstract][Full Text] [Related]
18. A novel electrochemical immunosensor based on colabeled silica nanoparticles for determination of total prostate specific antigen in human serum.
Qu B; Chu X; Shen G; Yu R
Talanta; 2008 Aug; 76(4):785-90. PubMed ID: 18656659
[TBL] [Abstract][Full Text] [Related]
19. Use of soybean peroxidase in chemiluminescent enzyme-linked immunosorbent assay.
Sakharov IY; Alpeeva IS; Efremov EE
J Agric Food Chem; 2006 Mar; 54(5):1584-7. PubMed ID: 16506804
[TBL] [Abstract][Full Text] [Related]
20. Gold nanoparticles based sandwich electrochemical immunosensor.
Ahirwal GK; Mitra CK
Biosens Bioelectron; 2010 May; 25(9):2016-20. PubMed ID: 20171869
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]