These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

176 related articles for article (PubMed ID: 19362899)

  • 1. Modeling of multiarticular muscles: importance of inclusion of tendon-pulley interactions in the finger.
    Lee SW; Kamper DG
    IEEE Trans Biomed Eng; 2009 Sep; 56(9):2253-62. PubMed ID: 19362899
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Finger flexor motor control patterns during active flexion: an in vivo tendon force study.
    Nikanjam M; Kursa K; Lehman S; Lattanza L; Diao E; Rempel D
    Hum Mov Sci; 2007 Feb; 26(1):1-10. PubMed ID: 17173995
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Estimation of finger muscle tendon tensions and pulley forces during specific sport-climbing grip techniques.
    Vigouroux L; Quaine F; Labarre-Vila A; Moutet F
    J Biomech; 2006; 39(14):2583-92. PubMed ID: 16225880
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Changes in the flexor digitorum profundus tendon geometry in the carpal tunnel due to force production and posture of metacarpophalangeal joint of the index finger: an MRI study.
    Martin JR; Paclet F; Latash ML; Zatsiorsky VM
    Clin Biomech (Bristol, Avon); 2013 Feb; 28(2):157-63. PubMed ID: 23219762
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Extrinsic flexor muscles generate concurrent flexion of all three finger joints.
    Kamper DG; George Hornby T; Rymer WZ
    J Biomech; 2002 Dec; 35(12):1581-9. PubMed ID: 12445611
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Intersegmental kinetics significantly impact mapping from finger musculotendon forces to fingertip forces.
    Qiu D; Lee SW; Amine M; Kamper DG
    J Biomech; 2017 Dec; 65():82-88. PubMed ID: 29102266
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of finger posture on the tendon force distribution within the finger extensor mechanism.
    Lee SW; Chen H; Towles JD; Kamper DG
    J Biomech Eng; 2008 Oct; 130(5):051014. PubMed ID: 19045521
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Releasing the A3 pulley and leaving flexor superficialis intact increases pinch force following the Zancolli lasso procedures to prevent claw deformity in the intrinsic palsied finger.
    Valero-Cuevas FJ; Hentz VR
    J Orthop Res; 2002 Sep; 20(5):902-9. PubMed ID: 12382952
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessing Finger Joint Biomechanics by Applying Equal Force to Flexor Tendons In Vitro Using a Novel Simultaneous Approach.
    Yang TH; Lu SC; Lin WJ; Zhao K; Zhao C; An KN; Jou IM; Lee PY; Kuo LC; Su FC
    PLoS One; 2016; 11(8):e0160301. PubMed ID: 27513744
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flexor digitorum profundus tendon tension during finger manipulation.
    Tanaka T; Amadio PC; Zhao C; Zobitz ME; An KN
    J Hand Ther; 2005; 18(3):330-8; quiz 338. PubMed ID: 16059854
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of flexor digitorum superficialis on gliding function of the flexor digitorum profundus according to regions in zone II.
    Tang JB; Xu Y; Chen F
    J Hand Surg Am; 2003 Sep; 28(5):838-44. PubMed ID: 14507516
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vivo flexor tendon forces increase with finger and wrist flexion during active finger flexion and extension.
    Kursa K; Lattanza L; Diao E; Rempel D
    J Orthop Res; 2006 Apr; 24(4):763-9. PubMed ID: 16514639
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Incorporating the length-dependent passive-force generating muscle properties of the extrinsic finger muscles into a wrist and finger biomechanical musculoskeletal model.
    Binder-Markey BI; Murray WM
    J Biomech; 2017 Aug; 61():250-257. PubMed ID: 28774467
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Biomechanical study of flexor tendon and finger motor function].
    Zhang Z; Xiong Y
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2009 Dec; 26(6):1267-70. PubMed ID: 20095484
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The moment arms and leverage of the human finger muscles.
    Francis-Pester FW; Thomas R; Sforzin D; Ackland DC
    J Biomech; 2021 Feb; 116():110180. PubMed ID: 33508758
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Friction between finger flexor tendons and the pulley system in the crimp grip position.
    Moor BK; Nagy L; Snedeker JG; Schweizer A
    Clin Biomech (Bristol, Avon); 2009 Jan; 24(1):20-5. PubMed ID: 19041166
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Variations of the flexor digitorum superficialis as determined by an expanded clinical examination.
    Tan JS; Oh L; Louis DS
    J Hand Surg Am; 2009; 34(5):900-6. PubMed ID: 19410995
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A biomechanical study of the flexor digitorum superficialis: effects of digital pulley excision and loss of the flexor digitorum profundus.
    Hamman J; Ali A; Phillips C; Cunningham B; Mass DP
    J Hand Surg Am; 1997 Mar; 22(2):328-35. PubMed ID: 9195435
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Estimation of the effective static moment arms of the tendons in the index finger extensor mechanism.
    Lee SW; Chen H; Towles JD; Kamper DG
    J Biomech; 2008; 41(7):1567-73. PubMed ID: 18387615
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Maximum finger force prediction using a planar simulation of the middle finger.
    Lee JW; Rim K
    Proc Inst Mech Eng H; 1990; 204(3):169-78. PubMed ID: 2133783
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.