271 related articles for article (PubMed ID: 19377381)
1. Transesophageal echocardiography and transcranial color Doppler: independent or complementary diagnostic tests for cardiologists in the detection of patent foramen ovale?
Mangiafico S; Scandura S; Ussia GP; Privitera A; Capodanno D; Petralia A; Tamburino C
J Cardiovasc Med (Hagerstown); 2009 Feb; 10(2):143-8. PubMed ID: 19377381
[TBL] [Abstract][Full Text] [Related]
2. Contrast transcranial Doppler can diagnose large patent foramen ovale.
Kobayashi K; Iguchi Y; Kimura K; Okada Y; Terasawa Y; Matsumoto N; Sakai K; Aoki J; Shibazaki K
Cerebrovasc Dis; 2009; 27(3):230-4. PubMed ID: 19176955
[TBL] [Abstract][Full Text] [Related]
3. Transthoracic second harmonic two- and three-dimensional echocardiography for detection of patent foramen ovale.
Maffè S; Dellavesa P; Zenone F; Paino AM; Paffoni P; Perucca A; Kozel D; Signorotti F; Bielli M; Parravicini U; Pardo NF; Cucchi L; Aymele AG; Zanetta M
Eur J Echocardiogr; 2010 Jan; 11(1):57-63. PubMed ID: 19910318
[TBL] [Abstract][Full Text] [Related]
4. [Low sensitivity of the echocardiograph compared with contrast transcranial Doppler in right-to-left shunt].
Martínez-Sánchez P; Medina-Báez J; Lara-Lara M; Oliva-Navarro J; Cazorla-García R; Ruiz-Ares G; Martínez-Martínez M; Fuentes B; Díez-Tejedor E
Neurologia; 2012 Mar; 27(2):61-7. PubMed ID: 21889234
[TBL] [Abstract][Full Text] [Related]
5. Transcranial Doppler is Complementary to Echocardiography for Detection and Risk Stratification of Patent Foramen Ovale.
Tobe J; Bogiatzi C; Munoz C; Tamayo A; Spence JD
Can J Cardiol; 2016 Aug; 32(8):986.e9-986.e16. PubMed ID: 26952158
[TBL] [Abstract][Full Text] [Related]
6. Alternative ultrasound windows and sensitivity of contrast transcranial Doppler in patients with patent foramen ovale.
Topcuoglu MA
Cerebrovasc Dis; 2009; 28(2):205-6. PubMed ID: 19571534
[No Abstract] [Full Text] [Related]
7. Accuracy of transcranial Doppler for the diagnosis of intracardiac right-to-left shunt: a bivariate meta-analysis of prospective studies.
Mojadidi MK; Roberts SC; Winoker JS; Romero J; Goodman-Meza D; Gevorgyan R; Tobis JM
JACC Cardiovasc Imaging; 2014 Mar; 7(3):236-50. PubMed ID: 24560213
[TBL] [Abstract][Full Text] [Related]
8. Diagnosis of secondary source of right-to-left shunt with balloon occlusion of patent foramen ovale and power M-mode transcranial Doppler.
Jesurum JT; Fuller CJ; Renz J; Krabill KA; Spencer MP; Reisman M
JACC Cardiovasc Interv; 2009 Jun; 2(6):561-7. PubMed ID: 19539262
[TBL] [Abstract][Full Text] [Related]
9. Diagnosis and quantification of patent foramen ovale. Which is the reference technique? Simultaneous study with transcranial Doppler, transthoracic and transesophageal echocardiography.
González-Alujas T; Evangelista A; Santamarina E; Rubiera M; Gómez-Bosch Z; Rodríguez-Palomares JF; Avegliano G; Molina C; Alvarez-Sabín J; García-Dorado D
Rev Esp Cardiol; 2011 Feb; 64(2):133-9. PubMed ID: 21277667
[TBL] [Abstract][Full Text] [Related]
10. Transcranial Doppler detection of venous-to-arterial circulation shunts: criteria for patent foramen ovale.
Sastry S; MacNab A; Daly K; Ray S; McCollum C
J Clin Ultrasound; 2009 Jun; 37(5):276-80. PubMed ID: 19353576
[TBL] [Abstract][Full Text] [Related]
11. Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale.
He JC; Zheng JY; Li X; Yang Y; Zhang BY; Chen Y; Li XF; Liu YM; Cao Y; Zhao L; Li TC
Int J Cardiovasc Imaging; 2017 Aug; 33(8):1125-1131. PubMed ID: 28176181
[TBL] [Abstract][Full Text] [Related]
12. Need for performance protocols in TEE and TCD for detection of right to left shunts.
Chang J; Darbonne C; Drumm DA; Teleb MS; Frey JL
J Neuroimaging; 2014; 24(2):144-8. PubMed ID: 22913674
[TBL] [Abstract][Full Text] [Related]
13. [Detection of patent foramen ovale. Transesophageal echocardiography and transcranial Doppler sonography with ultrasound contrast media are "supplementary, not competing, diagnostic methods"].
Heckmann JG; Niedermeier W; Brandt-Pohlmann M; Hilz MJ; Hecht M; Neundörfer B
Med Klin (Munich); 1999 Jul; 94(7):367-70. PubMed ID: 10437366
[TBL] [Abstract][Full Text] [Related]
14. Transcranial Doppler for stratification of high-risk morphology of patent foramen ovale in patients with cryptogenic stroke.
Chino S; Mochizuki Y; Mizuma K; Ichikawa S; Miyazaki H; Hachiya R; Toyosaki E; Ota M; Fukuoka H; Yamochi T; Ono K; Shinke T
Heart Vessels; 2022 Dec; 37(12):2119-2127. PubMed ID: 35701559
[TBL] [Abstract][Full Text] [Related]
15. Patent foramen ovale: comparison among diagnostic strategies in cryptogenic stroke and migraine.
Zito C; Dattilo G; Oreto G; Di Bella G; Lamari A; Iudicello R; Trio O; Caracciolo G; Coglitore S; Arrigo F; Carerj S
Echocardiography; 2009 May; 26(5):495-503. PubMed ID: 19452605
[TBL] [Abstract][Full Text] [Related]
16. Transcranial Doppler ultrasonography should it be the first choice for persistent foramen ovale screening?
Komar M; Olszowska M; Przewłocki T; Podolec J; Stępniewski J; Sobień B; Badacz R; Kabłak-Ziembicka A; Tomkiewicz-Pająk L; Podolec P
Cardiovasc Ultrasound; 2014 May; 12():16. PubMed ID: 24884981
[TBL] [Abstract][Full Text] [Related]
17. Diagnostic Value of Micro-Bubble Transcranial Doppler Combined with Contrast Transthoracic Echocardiography in Cryptogenic Stroke Patients with Patent Foramen Ovale.
Lu J; Li J; Huang H; Ye Q
Neurol India; 2022; 70(4):1403-1406. PubMed ID: 36076635
[TBL] [Abstract][Full Text] [Related]
18. Comparative analysis of the diagnostic value of several methods for the diagnosis of patent foramen ovale.
Liu F; Kong Q; Zhang X; Li Y; Liang S; Han S; Li G
Echocardiography; 2021 May; 38(5):790-797. PubMed ID: 33870543
[TBL] [Abstract][Full Text] [Related]
19. Comparative diagnostic accuracy of transcranial Doppler and contrast-enhanced transthoracic echocardiography for the diagnosis of patent foramen ovale and atrial septal defect.
Lanzone AM; Castelluccio EV; Della Pina P; Boldi E; Lussardi G; Frati G; Gaudio C; Biondi-Zoccai G
Panminerva Med; 2024 Jun; 66(2):124-130. PubMed ID: 38563605
[TBL] [Abstract][Full Text] [Related]
20. Transcranial Doppler ultrasonography as a screening technique for detection of a patent foramen ovale before surgery in the sitting position.
Stendel R; Gramm HJ; Schröder K; Lober C; Brock M
Anesthesiology; 2000 Oct; 93(4):971-5. PubMed ID: 11020748
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]