127 related articles for article (PubMed ID: 19381103)
41. Dimensional accuracy of computer-aided design/computer-assisted manufactured orbital prostheses.
Marafon PG; Mattos BS; Sabóia AC; Noritomi PY
Int J Prosthodont; 2010; 23(3):271-6. PubMed ID: 20552095
[TBL] [Abstract][Full Text] [Related]
42. Retention and load transfer characteristics of implant-retained auricular prostheses.
Williams BH; Ochiai KT; Baba T; Caputo AA
Int J Oral Maxillofac Implants; 2007; 22(3):366-72. PubMed ID: 17622002
[TBL] [Abstract][Full Text] [Related]
43. Three-dimensional image correlation analyses for strains generated by cement and screw-retained implant prostheses.
Clelland NL; Yilmaz B; Seidt JD
Clin Implant Dent Relat Res; 2013 Apr; 15(2):271-82. PubMed ID: 22171595
[TBL] [Abstract][Full Text] [Related]
44. Stress distribution after installation of fixed frameworks with marginal gaps over angled and parallel implants: a photoelastic analysis.
Markarian RA; Ueda C; Sendyk CL; Laganá DC; Souza RM
J Prosthodont; 2007; 16(2):117-22. PubMed ID: 17362421
[TBL] [Abstract][Full Text] [Related]
45. Stress distribution around maxillary implants in anatomic photoelastic models of varying geometry. Part II.
Gross MD; Nissan J
J Prosthet Dent; 2001 May; 85(5):450-4. PubMed ID: 11357070
[TBL] [Abstract][Full Text] [Related]
46. Mechanical behavior of dental implants in different positions in the rehabilitation of the anterior maxilla.
Corrêa CB; Margonar R; Noritomi PY; Vaz LG
J Prosthet Dent; 2014 Apr; 111(4):301-9. PubMed ID: 24355510
[TBL] [Abstract][Full Text] [Related]
47. Photoelastic analysis of the effect of palatal support on various implant-supported overdenture designs.
Ochiai KT; Williams BH; Hojo S; Nishimura R; Caputo AA
J Prosthet Dent; 2004 May; 91(5):421-7. PubMed ID: 15153848
[TBL] [Abstract][Full Text] [Related]
48. Mechanical behavior and color change of facial prosthetic elastomers after outdoor weathering in a hot and humid climate.
Al-Harbi FA; Ayad NM; Saber MA; ArRejaie AS; Morgano SM
J Prosthet Dent; 2015 Feb; 113(2):146-51. PubMed ID: 25455267
[TBL] [Abstract][Full Text] [Related]
49. A modified technique for retention of orbital prosthesis.
Shaikh SR; Patil PG; Puri S
Indian J Dent Res; 2011; 22(6):863-5. PubMed ID: 22484888
[TBL] [Abstract][Full Text] [Related]
50. Photoelastic stress analysis in prosthetic implants of different diameters: mini, narrow, standard or wide.
Coelho Goiato M; Pesqueira AA; Santos DM; Haddad MF; Moreno A
J Clin Diagn Res; 2014 Sep; 8(9):ZC86-90. PubMed ID: 25386531
[TBL] [Abstract][Full Text] [Related]
51. Biomechanical Analysis of Implant-Supported Prostheses with Different Implant-Abutment Connections.
Dayrell AC; Noritomi PY; Takahashi JM; Consani RL; Mesquita MF; dos Santos MB
Int J Prosthodont; 2015; 28(6):621-3. PubMed ID: 26523723
[TBL] [Abstract][Full Text] [Related]
52. Mechanical evaluation of craniofacial osseointegration retention systems.
Del Valle V; Faulkner G; Wolfaardt J; Rangert B; Tan HK
Int J Oral Maxillofac Implants; 1995; 10(4):491-8. PubMed ID: 7672853
[TBL] [Abstract][Full Text] [Related]
53. Comparison of single-standing or connected implants on stress distribution in bone of mandibular overdentures: a two-dimensional finite element analysis.
Tabata LF; Assunção WG; Barão VA; Gomes EA; Delben JA; de Sousa EA; Rocha EP
J Craniofac Surg; 2010 May; 21(3):696-702. PubMed ID: 20485031
[TBL] [Abstract][Full Text] [Related]
54. Stress distribution in bone simulation model with pre-angled implants.
Goiato MC; Arsufi GS; de Medeiros RA; Pesqueira AA; Guiotti AM; dos Santos DM
J Med Eng Technol; 2015; 39(6):322-7. PubMed ID: 26100976
[TBL] [Abstract][Full Text] [Related]
55. Effect of crown to implant ratio and implant dimensions on periimplant stress of splinted implant-supported crowns: a finite element analysis.
Bayraktar M; Gultekin BA; Yalcin S; Mijiritsky E
Implant Dent; 2013 Aug; 22(4):406-13. PubMed ID: 23823738
[TBL] [Abstract][Full Text] [Related]
56. Magnet-Retained Orbital Prosthesis Using a Dental Implant.
Kim SM
J Craniofac Surg; 2017 Mar; 28(2):e151-e152. PubMed ID: 28045820
[TBL] [Abstract][Full Text] [Related]
57. A photoelastic stress analysis of screw- and cement-retained implant prostheses with marginal gaps.
Lee JI; Lee Y; Kim NY; Kim YL; Cho HW
Clin Implant Dent Relat Res; 2013 Oct; 15(5):735-49. PubMed ID: 23927066
[TBL] [Abstract][Full Text] [Related]
58. Finite element analysis of stress in bone adjacent to dental implants.
Rubo JH; Souza EA
J Oral Implantol; 2008; 34(5):248-55. PubMed ID: 19170290
[TBL] [Abstract][Full Text] [Related]
59. Finite element analysis of stability and functional stress with implant-supported maxillary obturator prostheses.
de Sousa AA; Mattos BS
J Prosthet Dent; 2014 Dec; 112(6):1578-84. PubMed ID: 25277029
[TBL] [Abstract][Full Text] [Related]
60. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.
Merıç G; Erkmen E; Kurt A; Eser A; özden AU
Acta Odontol Scand; 2011 Nov; 69(6):374-84. PubMed ID: 21449688
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]