These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
119 related articles for article (PubMed ID: 19394025)
1. In-vitro experimental assessment of a new robust algorithm for hip joint centre estimation. De Momi E; Lopomo N; Cerveri P; Zaffagnini S; Safran MR; Ferrigno G J Biomech; 2009 May; 42(8):989-95. PubMed ID: 19394025 [TBL] [Abstract][Full Text] [Related]
2. An optimized protocol for hip joint centre determination using the functional method. Camomilla V; Cereatti A; Vannozzi G; Cappozzo A J Biomech; 2006; 39(6):1096-106. PubMed ID: 16549099 [TBL] [Abstract][Full Text] [Related]
3. Detection of the center of the hip joint in computer-assisted surgery: an evaluation study of the Surgetics algorithm. Stindel E; Gil D; Briard JL; Merloz P; Dubrana F; Lefevre C Comput Aided Surg; 2005 May; 10(3):133-9. PubMed ID: 16321910 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of a new algorithm to determine the hip joint center. Siston RA; Delp SL J Biomech; 2006; 39(1):125-30. PubMed ID: 16271596 [TBL] [Abstract][Full Text] [Related]
5. Effects of movement for estimating the hip joint centre. Begon M; Monnet T; Lacouture P Gait Posture; 2007 Mar; 25(3):353-9. PubMed ID: 16733087 [TBL] [Abstract][Full Text] [Related]
6. Hip joint centre localisation with an unscented Kalman filter. De Momi E; Beretta E; Ferrigno G Comput Methods Biomech Biomed Engin; 2013; 16(12):1319-29. PubMed ID: 22463592 [TBL] [Abstract][Full Text] [Related]
7. Hip joint centre position estimation using a dual unscented Kalman filter for computer-assisted orthopaedic surgery. Beretta E; De Momi E; Camomilla V; Cereatti A; Cappozzo A; Ferrigno G Proc Inst Mech Eng H; 2014 Sep; 228(9):971-82. PubMed ID: 25313027 [TBL] [Abstract][Full Text] [Related]
8. Propagation of the hip joint centre location error to the estimate of femur vs pelvis orientation using a constrained or an unconstrained approach. Cereatti A; Camomilla V; Vannozzi G; Cappozzo A J Biomech; 2007; 40(6):1228-34. PubMed ID: 16876805 [TBL] [Abstract][Full Text] [Related]
9. Hip joint centre location: an ex vivo study. Cereatti A; Donati M; Camomilla V; Margheritini F; Cappozzo A J Biomech; 2009 May; 42(7):818-23. PubMed ID: 19268947 [TBL] [Abstract][Full Text] [Related]
10. Test bed for assessment of the kinematical determination of navigation systems for total knee arthroplasty. Does a limited range of motion of the hip joint influence the accuracy of the determination? Schwarz ML; Pott PP; Beck A; Heute S; Scharf HP Comput Aided Surg; 2005 Jan; 10(1):51-7. PubMed ID: 16199382 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of formal methods in hip joint center assessment: an in vitro analysis. Lopomo N; Sun L; Zaffagnini S; Giordano G; Safran MR Clin Biomech (Bristol); 2010 Mar; 25(3):206-12. PubMed ID: 20006913 [TBL] [Abstract][Full Text] [Related]
13. Force-plate based computation of ankle and hip strategies from double-inverted pendulum model. Colobert B; Crétual A; Allard P; Delamarche P Clin Biomech (Bristol); 2006 May; 21(4):427-34. PubMed ID: 16442676 [TBL] [Abstract][Full Text] [Related]
14. Kalman smoothing improves the estimation of joint kinematics and kinetics in marker-based human gait analysis. De Groote F; De Laet T; Jonkers I; De Schutter J J Biomech; 2008 Dec; 41(16):3390-8. PubMed ID: 19026414 [TBL] [Abstract][Full Text] [Related]
15. Subject-specific hip geometry and hip joint centre location affects calculated contact forces at the hip during gait. Lenaerts G; Bartels W; Gelaude F; Mulier M; Spaepen A; Van der Perre G; Jonkers I J Biomech; 2009 Jun; 42(9):1246-51. PubMed ID: 19464012 [TBL] [Abstract][Full Text] [Related]
16. A framework for the functional identification of joint centers using markerless motion capture, validation for the hip joint. Corazza S; Mündermann L; Andriacchi T J Biomech; 2007; 40(15):3510-5. PubMed ID: 17697684 [TBL] [Abstract][Full Text] [Related]
17. The influence of hip abduction and external rotation on sacroiliac motion. Bussey MD; Bell ML; Milosavljevic S Man Ther; 2009 Oct; 14(5):520-5. PubMed ID: 18996734 [TBL] [Abstract][Full Text] [Related]
18. A contact algorithm for density-based load estimation. Bona MA; Martin LD; Fischer KJ J Biomech; 2006; 39(4):636-44. PubMed ID: 16439233 [TBL] [Abstract][Full Text] [Related]
19. Effective marker placement for functional identification of the centre of rotation at the hip. Kratzenstein S; Kornaropoulos EI; Ehrig RM; Heller MO; Pöpplau BM; Taylor WR Gait Posture; 2012 Jul; 36(3):482-6. PubMed ID: 22672896 [TBL] [Abstract][Full Text] [Related]
20. Sex differences in the pattern of innominate motion during passive hip abduction and external rotation. Bussey MD; Milosavljevic S; Bell ML Man Ther; 2009 Oct; 14(5):514-9. PubMed ID: 19027341 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]