These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

173 related articles for article (PubMed ID: 19398781)

  • 1. First application of Cc-corrected imaging for high-resolution and energy-filtered TEM.
    Kabius B; Hartel P; Haider M; Müller H; Uhlemann S; Loebau U; Zach J; Rose H
    J Electron Microsc (Tokyo); 2009 Jun; 58(3):147-55. PubMed ID: 19398781
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Prerequisites for a Cc/Cs-corrected ultrahigh-resolution TEM.
    Haider M; Müller H; Uhlemann S; Zach J; Loebau U; Hoeschen R
    Ultramicroscopy; 2008 Feb; 108(3):167-78. PubMed ID: 18060700
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Information transfer in a TEM corrected for spherical and chromatic aberration.
    Haider M; Hartel P; Müller H; Uhlemann S; Zach J
    Microsc Microanal; 2010 Aug; 16(4):393-408. PubMed ID: 20598203
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Breaking the spherical and chromatic aberration barrier in transmission electron microscopy.
    Freitag B; Kujawa S; Mul PM; Ringnalda J; Tiemeijer PC
    Ultramicroscopy; 2005 Feb; 102(3):209-14. PubMed ID: 15639351
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Progress in aberration-corrected high-resolution transmission electron microscopy using hardware aberration correction.
    Lentzen M
    Microsc Microanal; 2006 Jun; 12(3):191-205. PubMed ID: 17481356
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The influence of lens chromatic aberration on electron energy-loss spectroscopy quantitative measurements.
    Yang YY; Egerton RF
    Microsc Res Tech; 1992 Jun; 21(4):361-7. PubMed ID: 1638055
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Chromatic Aberration Correction for Atomic Resolution TEM Imaging from 20 to 80 kV.
    Linck M; Hartel P; Uhlemann S; Kahl F; Müller H; Zach J; Haider M; Niestadt M; Bischoff M; Biskupek J; Lee Z; Lehnert T; Börrnert F; Rose H; Kaiser U
    Phys Rev Lett; 2016 Aug; 117(7):076101. PubMed ID: 27563976
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A new aberration-corrected, energy-filtered LEEM/PEEM instrument. I. Principles and design.
    Tromp RM; Hannon JB; Ellis AW; Wan W; Berghaus A; Schaff O
    Ultramicroscopy; 2010 Jun; 110(7):852-61. PubMed ID: 20395048
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A sub-50meV spectrometer and energy filter for use in combination with 200kV monochromated (S)TEMs.
    Brink HA; Barfels MM; Burgner RP; Edwards BN
    Ultramicroscopy; 2003 Sep; 96(3-4):367-84. PubMed ID: 12871802
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Image simulation of high resolution energy filtered TEM images.
    Verbeeck J; Schattschneider P; Rosenauer A
    Ultramicroscopy; 2009 Mar; 109(4):350-60. PubMed ID: 19217718
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Using a monochromator to improve the resolution in TEM to below 0.5Å. Part I: Creating highly coherent monochromated illumination.
    Tiemeijer PC; Bischoff M; Freitag B; Kisielowski C
    Ultramicroscopy; 2012 Mar; 114():72-81. PubMed ID: 22356791
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sub-ångstrom resolution using aberration corrected electron optics.
    Batson PE; Dellby N; Krivanek OL
    Nature; 2002 Aug; 418(6898):617-20. PubMed ID: 12167855
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Structural imaging of beta-Si3N4 by spherical aberration-corrected high-resolution transmission electron microscopy.
    Zhang Z; Kaiser U
    Ultramicroscopy; 2009 Aug; 109(9):1114-20. PubMed ID: 19493621
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optimum HRTEM image contrast at 20 kV and 80 kV--exemplified by graphene.
    Lee Z; Meyer JC; Rose H; Kaiser U
    Ultramicroscopy; 2012 Jan; 112(1):39-46. PubMed ID: 22088506
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High-resolution transmission electron microscopy using negative spherical aberration.
    Jia CL; Lentzen M; Urban K
    Microsc Microanal; 2004 Apr; 10(2):174-84. PubMed ID: 15306044
    [TBL] [Abstract][Full Text] [Related]  

  • 16. First experimental test of a new monochromated and aberration-corrected 200 kV field-emission scanning transmission electron microscope.
    Walther T; Quandt E; Stegmann H; Thesen A; Benner G
    Ultramicroscopy; 2006; 106(11-12):963-9. PubMed ID: 16870338
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Atomic resolution elemental mapping using energy-filtered imaging scanning transmission electron microscopy with chromatic aberration correction.
    Krause FF; Rosenauer A; Barthel J; Mayer J; Urban K; Dunin-Borkowski RE; Brown HG; Forbes BD; Allen LJ
    Ultramicroscopy; 2017 Oct; 181():173-177. PubMed ID: 28601013
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Current and future aberration correctors for the improvement of resolution in electron microscopy.
    Haider M; Hartel P; Müller H; Uhlemann S; Zach J
    Philos Trans A Math Phys Eng Sci; 2009 Sep; 367(1903):3665-82. PubMed ID: 19687059
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Direct imaging of local atomic ordering in a Pd-Ni-P bulk metallic glass using Cs-corrected transmission electron microscopy.
    Hirata A; Hirotsu Y; Nieh TG; Ohkubo T; Tanaka N
    Ultramicroscopy; 2007; 107(2-3):116-23. PubMed ID: 16872747
    [TBL] [Abstract][Full Text] [Related]  

  • 20. 40 keV atomic resolution TEM.
    Bell DC; Russo CJ; Kolmykov DV
    Ultramicroscopy; 2012 Mar; 114():31-7. PubMed ID: 22356786
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.