119 related articles for article (PubMed ID: 19402191)
1. Randomized clinical trial of efficacy and costs of three dissection devices in liver resection.
Richter S; Kollmar O; Schuld J; Moussavian MR; Igna D; Schilling MK;
Br J Surg; 2009 Jun; 96(6):593-601. PubMed ID: 19402191
[TBL] [Abstract][Full Text] [Related]
2. The efficacy of three transection techniques of the liver resection: a randomized clinical trial.
Doklestic K; Karamarkovic A; Stefanovic B; Stefanovic B; Milic N; Gregoric P; Djukic V; Bajec D
Hepatogastroenterology; 2012; 59(117):1501-6. PubMed ID: 22115802
[TBL] [Abstract][Full Text] [Related]
3. How should transection of the liver be performed?: a prospective randomized study in 100 consecutive patients: comparing four different transection strategies.
Lesurtel M; Selzner M; Petrowsky H; McCormack L; Clavien PA
Ann Surg; 2005 Dec; 242(6):814-22, discussion 822-3. PubMed ID: 16327491
[TBL] [Abstract][Full Text] [Related]
4. Safety and Efficacy of a New Bipolar Energy Device for Parenchymal Dissection in Laparoscopic Liver Resection.
Dural C; Akyuz M; Yazici P; Aksoy E; Aucejo F; Quintini C; Miller C; Fung J; Berber E
Surg Laparosc Endosc Percutan Tech; 2016 Feb; 26(1):21-4. PubMed ID: 26836626
[TBL] [Abstract][Full Text] [Related]
5. Ultrasonic dissection in resection of hepatocellular carcinoma.
Chou FF; Chen CL; Sheen-Chen SM; Chen YS; Chen MC
Int Surg; 1995; 80(2):105-7. PubMed ID: 8530221
[TBL] [Abstract][Full Text] [Related]
6. Randomized clinical trial of stapler versus clamp-crushing transection in elective liver resection.
Rahbari NN; Elbers H; Koch M; Vogler P; Striebel F; Bruckner T; Mehrabi A; Schemmer P; Büchler MW; Weitz J
Br J Surg; 2014 Feb; 101(3):200-7. PubMed ID: 24402888
[TBL] [Abstract][Full Text] [Related]
7. A prospective randomized controlled trial of hemostasis with a bipolar sealer during hepatic transection for liver resection.
Kaibori M; Matsui K; Ishizaki M; Sakaguchi T; Matsushima H; Matsui Y; Kwon AH
Surgery; 2013 Nov; 154(5):1046-52. PubMed ID: 24075274
[TBL] [Abstract][Full Text] [Related]
8. [New liver surgery techniques. Few complications and more advantages?].
Wøjdemann M; Riber C; Burcharth F
Ugeskr Laeger; 2008 Apr; 170(16):1342-5. PubMed ID: 18433594
[TBL] [Abstract][Full Text] [Related]
9. A prospective evaluation of ultrasonic dissector plus harmonic scalpel in liver resection.
Arru M; Pulitanò C; Aldrighetti L; Catena M; Finazzi R; Ferla G
Am Surg; 2007 Mar; 73(3):256-60. PubMed ID: 17375782
[TBL] [Abstract][Full Text] [Related]
10. Is the TissueLink dissecting sealer a better liver resection device than clamp-crushing? A meta-analysis and system review.
Zhang S; Zheng Y; Wu B; Ji S; Yu Z; Zhang Q
Hepatogastroenterology; 2012; 59(120):2602-8. PubMed ID: 22626880
[TBL] [Abstract][Full Text] [Related]
11. Effectiveness of using ultrasonically activated scalpel in combination with radiofrequency dissecting sealer or irrigation bipolar for hepatic resection.
Yokoo H; Kamiyama T; Nakanishi K; Tahara M; Fukumori D; Kamachi H; Matsushita M; Todo S
Hepatogastroenterology; 2012 May; 59(115):831-5. PubMed ID: 22469727
[TBL] [Abstract][Full Text] [Related]
12. Usefulness of vessel-sealing devices combined with crush clamping method for hepatectomy: a retrospective cohort study.
Nanashima A; Abo T; Arai J; Takagi K; Matsumoto H; Takeshita H; Tsuchiya T; Nagayasu T
Int J Surg; 2013; 11(9):891-7. PubMed ID: 23954369
[TBL] [Abstract][Full Text] [Related]
13. Randomized clinical trial of radiofrequency-assisted versus clamp-crushing liver resection.
Lupo L; Gallerani A; Panzera P; Tandoi F; Di Palma G; Memeo V
Br J Surg; 2007 Mar; 94(3):287-91. PubMed ID: 17318804
[TBL] [Abstract][Full Text] [Related]
14. The three-surgeon technique for liver tissue dissection: towards real bloodless hepatectomy.
Petrou A; Kontos M; Prassas E; Bramis K; Papalambros A; Brennan N; Mihas C; Felekouras E
J BUON; 2012; 17(2):304-9. PubMed ID: 22740210
[TBL] [Abstract][Full Text] [Related]
15. Randomized clinical trial of the effect of a saline-linked radiofrequency coagulator on blood loss during hepatic resection.
Arita J; Hasegawa K; Kokudo N; Sano K; Sugawara Y; Makuuchi M
Br J Surg; 2005 Aug; 92(8):954-9. PubMed ID: 16034832
[TBL] [Abstract][Full Text] [Related]
16. The extent of resection influences outcome following hepatectomy for colorectal liver metastases.
Stewart GD; O'Súilleabháin CB; Madhavan KK; Wigmore SJ; Parks RW; Garden OJ
Eur J Surg Oncol; 2004 May; 30(4):370-6. PubMed ID: 15063889
[TBL] [Abstract][Full Text] [Related]
17. The vessel sealing system (LigaSure) in hepatic resection: a randomized controlled trial.
Ikeda M; Hasegawa K; Sano K; Imamura H; Beck Y; Sugawara Y; Kokudo N; Makuuchi M
Ann Surg; 2009 Aug; 250(2):199-203. PubMed ID: 19638927
[TBL] [Abstract][Full Text] [Related]
18. The impact of the CUSA ultrasonic dissection device on major liver resections.
Storck BH; Rutgers EJ; Gortzak E; Zoetmulder FA
Neth J Surg; 1991 Aug; 43(4):99-101. PubMed ID: 1944998
[TBL] [Abstract][Full Text] [Related]
19. [Surgical techniques in hepatic resections: Ultrasonic aspirator versus Jet-Cutter. A prospective randomized clinical trial].
Rau HG; Wichmann MW; Schinkel S; Buttler E; Pickelmann S; Schauer R; Schildberg FW
Zentralbl Chir; 2001 Aug; 126(8):586-90. PubMed ID: 11518996
[TBL] [Abstract][Full Text] [Related]
20. Suprahilar vascular control and stapling device transection of Glissonian pedicle in major and minor hepatectomies.
Karamarković A; Doklestić K; Popović N; Gregorić P; Vujadinović ST; Milić N
Hepatogastroenterology; 2013; 60(128):2060-8. PubMed ID: 24088312
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]