These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

382 related articles for article (PubMed ID: 19403298)

  • 1. An integrated microfluidic system for C-reactive protein measurement.
    Yang YN; Lin HI; Wang JH; Shiesh SC; Lee GB
    Biosens Bioelectron; 2009 Jun; 24(10):3091-6. PubMed ID: 19403298
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Integrated microfluidic system for rapid screening of CRP aptamers utilizing systematic evolution of ligands by exponential enrichment (SELEX).
    Huang CJ; Lin HI; Shiesh SC; Lee GB
    Biosens Bioelectron; 2010 Mar; 25(7):1761-6. PubMed ID: 20061133
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design and testing of a disposable microfluidic chemiluminescent immunoassay for disease biomarkers in human serum samples.
    Bhattacharyya A; Klapperich CM
    Biomed Microdevices; 2007 Apr; 9(2):245-51. PubMed ID: 17165125
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Aptamer-antibody on-chip sandwich immunoassay for detection of CRP in spiked serum.
    Pultar J; Sauer U; Domnanich P; Preininger C
    Biosens Bioelectron; 2009 Jan; 24(5):1456-61. PubMed ID: 18951012
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Electrochemical detection of high-sensitivity CRP inside a microfluidic device by numerical and experimental studies.
    Lee G; Park I; Kwon K; Kwon T; Seo J; Chang WJ; Nam H; Cha GS; Choi MH; Yoon DS; Lee SW
    Biomed Microdevices; 2012 Apr; 14(2):375-84. PubMed ID: 22143877
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Magnetic-bead-based microfluidic system for ribonucleic acid extraction and reverse transcription processes.
    Liu CJ; Lien KY; Weng CY; Shin JW; Chang TY; Lee GB
    Biomed Microdevices; 2009 Apr; 11(2):339-50. PubMed ID: 19034667
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Amplification of fluorescence with packed beads to enhance the sensitivity of miniaturized detection in microfluidic chip.
    Shin KS; Lee SW; Han KC; Kim SK; Yang EK; Park JH; Ju BK; Kang JY; Kim TS
    Biosens Bioelectron; 2007 Apr; 22(9-10):2261-7. PubMed ID: 17169549
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Disposable polydimethylsiloxane/silicon hybrid chips for protein detection.
    Li S; Floriano PN; Christodoulides N; Fozdar DY; Shao D; Ali MF; Dharshan P; Mohanty S; Neikirk D; McDevitt JT; Chen S
    Biosens Bioelectron; 2005 Oct; 21(4):574-80. PubMed ID: 16202870
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Micropumps, microvalves, and micromixers within PCR microfluidic chips: Advances and trends.
    Zhang C; Xing D; Li Y
    Biotechnol Adv; 2007; 25(5):483-514. PubMed ID: 17601695
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Microvalves actuated sandwich immunoassay on an integrated microfluidic system.
    Gao X; Jiang L; Su X; Qin J; Lin B
    Electrophoresis; 2009 Jul; 30(14):2481-7. PubMed ID: 19639569
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Demonstration of a direct capture immunoaffinity separation for C-reactive protein using a capillary-based microfluidic device.
    Peoples MC; Phillips TM; Karnes HT
    J Pharm Biomed Anal; 2008 Sep; 48(2):376-82. PubMed ID: 18178356
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Purification and enrichment of virus samples utilizing magnetic beads on a microfluidic system.
    Lien KY; Lin JL; Liu CY; Lei HY; Lee GB
    Lab Chip; 2007 Jul; 7(7):868-75. PubMed ID: 17594006
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Micro flow cytometry utilizing a magnetic bead-based immunoassay for rapid virus detection.
    Yang SY; Lien KY; Huang KJ; Lei HY; Lee GB
    Biosens Bioelectron; 2008 Dec; 24(4):861-8. PubMed ID: 18760587
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A multi-functional electrochemical sensing system using microfluidic technology for the detection of urea and creatinine.
    Huang CJ; Lin JL; Chen PH; Syu MJ; Lee GB
    Electrophoresis; 2011 Apr; 32(8):931-8. PubMed ID: 21437917
    [TBL] [Abstract][Full Text] [Related]  

  • 15. On-chip aptamer-based sandwich assay for thrombin detection employing magnetic beads and quantum dots.
    Tennico YH; Hutanu D; Koesdjojo MT; Bartel CM; Remcho VT
    Anal Chem; 2010 Jul; 82(13):5591-7. PubMed ID: 20545301
    [TBL] [Abstract][Full Text] [Related]  

  • 16. CRP determination based on a novel magnetic biosensor.
    Meyer MH; Hartmann M; Krause HJ; Blankenstein G; Mueller-Chorus B; Oster J; Miethe P; Keusgen M
    Biosens Bioelectron; 2007 Jan; 22(6):973-9. PubMed ID: 16766177
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Application of microchip assay system for the measurement of C-reactive protein in human saliva.
    Christodoulides N; Mohanty S; Miller CS; Langub MC; Floriano PN; Dharshan P; Ali MF; Bernard B; Romanovicz D; Anslyn E; Fox PC; McDevitt JT
    Lab Chip; 2005 Mar; 5(3):261-9. PubMed ID: 15726202
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simultaneous sample washing and concentration using a "trapping-and-releasing" mechanism of magnetic beads on a microfluidic chip.
    Ramadan Q; Gijs MA
    Analyst; 2011 Mar; 136(6):1157-66. PubMed ID: 21270982
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Microfluidic-based electrochemical genosensor coupled to magnetic beads for hybridization detection.
    Berti F; Laschi S; Palchetti I; Rossier JS; Reymond F; Mascini M; Marrazza G
    Talanta; 2009 Jan; 77(3):971-8. PubMed ID: 19064077
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fluorescence affinity sensing by using a self-contained fluid manoeuvring microfluidic chip.
    Hong JW; Chung KH; Yoon HC
    Analyst; 2008 Apr; 133(4):499-504. PubMed ID: 18365120
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.