240 related articles for article (PubMed ID: 19408476)
1. The effect of interimplant distance on the height of the interimplant bone crest when using platform-switched implants.
Rodríguez-Ciurana X; Vela-Nebot X; Segalà-Torres M; Calvo-Guirado JL; Cambra J; Méndez-Blanco V; Tarnow DP
Int J Periodontics Restorative Dent; 2009 Apr; 29(2):141-51. PubMed ID: 19408476
[TBL] [Abstract][Full Text] [Related]
2. Effect of interimplant distance (2 and 3 mm) on the height of interimplant bone crest: a histomorphometric evaluation.
Elian N; Bloom M; Dard M; Cho SC; Trushkowsky RD; Tarnow D
J Periodontol; 2011 Dec; 82(12):1749-56. PubMed ID: 21513475
[TBL] [Abstract][Full Text] [Related]
3. A randomized prospective multicenter trial evaluating the platform-switching technique for the prevention of postrestorative crestal bone loss.
Prosper L; Redaelli S; Pasi M; Zarone F; Radaelli G; Gherlone EF
Int J Oral Maxillofac Implants; 2009; 24(2):299-308. PubMed ID: 19492646
[TBL] [Abstract][Full Text] [Related]
4. Peri-implant bone level around implants with platform-switched abutments: preliminary data from a prospective study.
Hürzeler M; Fickl S; Zuhr O; Wachtel HC
J Oral Maxillofac Surg; 2007 Jul; 65(7 Suppl 1):33-9. PubMed ID: 17586347
[TBL] [Abstract][Full Text] [Related]
5. Peri-implant bone level around implants with platform-switched abutments.
Fickl S; Zuhr O; Stein JM; Hürzeler MB
Int J Oral Maxillofac Implants; 2010; 25(3):577-81. PubMed ID: 20556258
[TBL] [Abstract][Full Text] [Related]
6. Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogs.
Barros RR; Novaes AB; Muglia VA; Iezzi G; Piattelli A
Clin Oral Implants Res; 2010 Apr; 21(4):371-8. PubMed ID: 20128832
[TBL] [Abstract][Full Text] [Related]
7. The influence of individual bone patterns on peri-implant bone loss: preliminary report from a 3-year randomized clinical and histologic trial in patients treated with implants restored with matching-diameter abutments or the platform-switching concept.
Canullo L; Iannello G; Götz W
Int J Oral Maxillofac Implants; 2011; 26(3):618-30. PubMed ID: 21691610
[TBL] [Abstract][Full Text] [Related]
8. Benefits of an implant platform modification technique to reduce crestal bone resorption.
Vela-Nebot X; Rodríguez-Ciurana X; Rodado-Alonso C; Segalà-Torres M
Implant Dent; 2006 Sep; 15(3):313-20. PubMed ID: 16966906
[TBL] [Abstract][Full Text] [Related]
9. The relationship of bone resorption around dental implants to abutment design: a preliminary 1-year clinical study.
Hasan I; Heinemann F; Bourauel C
Int J Prosthodont; 2011; 24(5):457-9. PubMed ID: 21909487
[TBL] [Abstract][Full Text] [Related]
10. Prospective study of 94 platform-switched implants observed from 1992 to 2006.
Wagenberg B; Froum SJ
Int J Periodontics Restorative Dent; 2010 Feb; 30(1):9-17. PubMed ID: 20224827
[TBL] [Abstract][Full Text] [Related]
11. Influence of the 3-D bone-to-implant relationship on esthetics.
Grunder U; Gracis S; Capelli M
Int J Periodontics Restorative Dent; 2005 Apr; 25(2):113-9. PubMed ID: 15839587
[TBL] [Abstract][Full Text] [Related]
12. Scalloped implant designs enhance interproximal bone levels.
McAllister BS
Int J Periodontics Restorative Dent; 2007 Feb; 27(1):9-15. PubMed ID: 17370657
[TBL] [Abstract][Full Text] [Related]
13. The effect of inter-implant distance on the height of inter-implant bone crest.
Tarnow DP; Cho SC; Wallace SS
J Periodontol; 2000 Apr; 71(4):546-9. PubMed ID: 10807116
[TBL] [Abstract][Full Text] [Related]
14. The effect of abutment dis/reconnections on peri-implant bone resorption: a radiologic study of platform-switched and non-platform-switched implants placed in animals.
Rodríguez X; Vela X; Méndez V; Segalà M; Calvo-Guirado JL; Tarnow DP
Clin Oral Implants Res; 2013 Mar; 24(3):305-11. PubMed ID: 22092773
[TBL] [Abstract][Full Text] [Related]
15. Immediately loaded titanium implant with a tissue-stabilizing/maintaining design ('beyond platform switch') retrieved from man after 4 weeks: a histological and histomorphometrical evaluation. A case report.
Degidi M; Iezzi G; Scarano A; Piattelli A
Clin Oral Implants Res; 2008 Mar; 19(3):276-82. PubMed ID: 18081870
[TBL] [Abstract][Full Text] [Related]
16. Influence of the interimplant distance on crestal bone resorption and bone density: a histomorphometric study in dogs.
Papalexiou V; Novaes AB; Ribeiro RF; Muglia V; Oliveira RR
J Periodontol; 2006 Apr; 77(4):614-21. PubMed ID: 16584342
[TBL] [Abstract][Full Text] [Related]
17. A prospective, randomized, controlled comparison of platform-switched and matched-abutment implants in short-span partial denture situations.
Trammell K; Geurs NC; O'Neal SJ; Liu PR; Haigh SJ; McNeal S; Kenealy JN; Reddy MS
Int J Periodontics Restorative Dent; 2009 Dec; 29(6):599-605. PubMed ID: 20072737
[TBL] [Abstract][Full Text] [Related]
18. Soft tissues around long-term platform switching implant restorations: a histological human evaluation. Preliminary results.
Canullo L; Pellegrini G; Allievi C; Trombelli L; Annibali S; Dellavia C
J Clin Periodontol; 2011 Jan; 38(1):86-94. PubMed ID: 21062338
[TBL] [Abstract][Full Text] [Related]
19. Interproximal tissue dimensions in relation to adjacent implants in the anterior maxilla: clinical observations and patient aesthetic evaluation.
Kourkouta S; Dedi KD; Paquette DW; Mol A
Clin Oral Implants Res; 2009 Dec; 20(12):1375-85. PubMed ID: 19681967
[TBL] [Abstract][Full Text] [Related]
20. Effect of platform switching on implant crest bone stress: a finite element analysis.
Schrotenboer J; Tsao YP; Kinariwala V; Wang HL
Implant Dent; 2009 Jun; 18(3):260-9. PubMed ID: 19509536
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]