BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

351 related articles for article (PubMed ID: 19417914)

  • 1. A rapid, reliable, and automatable lab-on-a-chip interface.
    Kortmann H; Blank LM; Schmid A
    Lab Chip; 2009 May; 9(10):1455-60. PubMed ID: 19417914
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Fit-to-Flow (F2F) interconnects: universal reversible adhesive-free microfluidic adaptors for lab-on-a-chip systems.
    Chen A; Pan T
    Lab Chip; 2011 Feb; 11(4):727-32. PubMed ID: 21109877
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A vacuum manifold for rapid world-to-chip connectivity of complex PDMS microdevices.
    Cooksey GA; Plant AL; Atencia J
    Lab Chip; 2009 May; 9(9):1298-300. PubMed ID: 19370253
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Macro-to-micro interfaces for microfluidic devices.
    Fredrickson CK; Fan ZH
    Lab Chip; 2004 Dec; 4(6):526-33. PubMed ID: 15570361
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Reusable, compression-sealed fluid cells for surface mounting to planar substrates.
    Tamanaha CR; Malito MP; Mulvaney SP; Whitman LJ
    Lab Chip; 2009 May; 9(10):1468-71. PubMed ID: 19417916
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Droplet-on-a-wristband: chip-to-chip digital microfluidic interfaces between replaceable and flexible electrowetting modules.
    Fan SK; Yang H; Hsu W
    Lab Chip; 2011 Jan; 11(2):343-7. PubMed ID: 20957291
    [TBL] [Abstract][Full Text] [Related]  

  • 7. On-chip connector valve for immunoaffinity chromatography in a microfluidic chip.
    Shimura K; Koyama Y; Sato K; Kitamori T
    J Sep Sci; 2007 Jul; 30(10):1477-81. PubMed ID: 17623428
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Microfluidic chip accomplishing self-fluid replacement using only capillary force and its bioanalytical application.
    Chung KH; Hong JW; Lee DS; Yoon HC
    Anal Chim Acta; 2007 Feb; 585(1):1-10. PubMed ID: 17386640
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multiscale variation-aware techniques for high-performance digital microfluidic lab-on-a-chip component placement.
    Liao C; Hu S
    IEEE Trans Nanobioscience; 2011 Mar; 10(1):51-8. PubMed ID: 21511570
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Polymerase chain reaction of 2-kb cyanobacterial gene and human anti-alpha1-chymotrypsin gene from genomic DNA on the In-Check single-use microfabricated silicon chip.
    Consolandi C; Severgnini M; Frosini A; Caramenti G; De Fazio M; Ferrara F; Zocco A; Fischetti A; Palmieri M; De Bellis G
    Anal Biochem; 2006 Jun; 353(2):191-7. PubMed ID: 16620755
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Lab-on-a-chip with integrated optical transducers.
    Balslev S; Jorgensen AM; Bilenberg B; Mogensen KB; Snakenborg D; Geschke O; Kutter JP; Kristensen A
    Lab Chip; 2006 Feb; 6(2):213-7. PubMed ID: 16450030
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Connecting microfluidic chips using a chemically inert, reversible, multichannel chip-to-world-interface.
    Wilhelm E; Neumann C; Duttenhofer T; Pires L; Rapp BE
    Lab Chip; 2013 Nov; 13(22):4343-51. PubMed ID: 24056989
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Numerical and experimental evaluation of microfluidic sorting devices.
    Taylor JK; Ren CL; Stubley GD
    Biotechnol Prog; 2008; 24(4):981-91. PubMed ID: 19194907
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Low cost and manufacturable complete microTAS for detecting bacteria.
    Sauer-Budge AF; Mirer P; Chatterjee A; Klapperich CM; Chargin D; Sharon A
    Lab Chip; 2009 Oct; 9(19):2803-10. PubMed ID: 19967117
    [TBL] [Abstract][Full Text] [Related]  

  • 15. World-to-chip microfluidic interface with built-in valves for multichamber chip-based PCR assays.
    Oh KW; Park C; Namkoong K; Kim J; Ock KS; Kim S; Kim YA; Cho YK; Ko C
    Lab Chip; 2005 Aug; 5(8):845-50. PubMed ID: 16027935
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Separation of proteins using a novel two-depth miniaturized free-flow electrophoresis device with multiple outlet fractionation channels.
    Becker M; Marggraf U; Janasek D
    J Chromatogr A; 2009 Nov; 1216(47):8265-9. PubMed ID: 19631324
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Water-assisted CO(2) laser ablated glass and modified thermal bonding for capillary-driven bio-fluidic application.
    Chung CK; Chang HC; Shih TR; Lin SL; Hsiao EJ; Chen YS; Chang EC; Chen CC; Lin CC
    Biomed Microdevices; 2010 Feb; 12(1):107-14. PubMed ID: 19830566
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Interconnected reversible lab-on-a-chip technology.
    Igata E; Arundell M; Morgan H; Cooper JM
    Lab Chip; 2002 May; 2(2):65-9. PubMed ID: 15100836
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hand-held microanalytical instrument for chip-based electrophoretic separations of proteins.
    Renzi RF; Stamps J; Horn BA; Ferko S; Vandernoot VA; West JA; Crocker R; Wiedenman B; Yee D; Fruetel JA
    Anal Chem; 2005 Jan; 77(2):435-41. PubMed ID: 15649038
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nanofluidics in lab-on-a-chip devices.
    Kovarik ML; Jacobson SC
    Anal Chem; 2009 Sep; 81(17):7133-40. PubMed ID: 19663470
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.