BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

299 related articles for article (PubMed ID: 19418868)

  • 1. Prosthetic screw detorque values in implants retained as cast bar superstructures or bars modified by the Cresco Ti Precision technique--a comparative in vivo study.
    Schmitt J; Holst S; Eitner S; Schlegel A; Wichmann M; Hamel J
    Int J Prosthodont; 2009; 22(2):193-200. PubMed ID: 19418868
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effect of different screw-tightening techniques on the stress generated on an internal-connection implant superstructure.
    Choi JH; Lim YJ; Kim CW; Kim MJ
    Int J Oral Maxillofac Implants; 2009; 24(6):1045-53. PubMed ID: 20162108
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Immediate occlusal loading of implants in the partially edentate mandible: a prospective 1-year radiographic and 4-year clinical study.
    Ostman PO; Hellman M; Sennerby L
    Int J Oral Maxillofac Implants; 2008; 23(2):315-22. PubMed ID: 18548929
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A prospective 5-year multicenter study of the Cresco implantology concept.
    Helldén L; Ericson G; Elliot A; Fornell J; Holmgren K; Nilner K; Olsson CO
    Int J Prosthodont; 2003; 16(5):554-62. PubMed ID: 14651245
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Insertion torque and resonance frequency analysis of dental implant systems in an animal model with loaded implants.
    Al-Nawas B; Wagner W; Grötz KA
    Int J Oral Maxillofac Implants; 2006; 21(5):726-32. PubMed ID: 17066633
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The effect of eliminating implant/abutment rotational misfit on screw joint stability.
    Binon PP; McHugh MJ
    Int J Prosthodont; 1996; 9(6):511-9. PubMed ID: 9171488
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Within-subject comparison of two rigid bar designs connecting two interforaminal implants: patients' satisfaction and prosthetic results.
    Mericske-Stern R; Probst D; Fahrländer F; Schellenberg M
    Clin Implant Dent Relat Res; 2009 Sep; 11(3):228-37. PubMed ID: 18783424
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of casting procedures on screw loosening in UCLA-type abutments.
    Kano SC; Binon P; Bonfante G; Curtis DA
    J Prosthodont; 2006; 15(2):77-81. PubMed ID: 16650006
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Modified section method for laser-welding of ill-fitting cp Ti and Ni-Cr alloy one-piece cast implant-supported frameworks.
    Tiossi R; Falcão-Filho H; Aguiar Júnior FA; Rodrigues RC; Mattos Mda G; Ribeiro RF
    J Oral Rehabil; 2010 May; 37(5):359-63. PubMed ID: 20149062
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reverse torque failure of screw-shaped implants in baboons: baseline data for abutment torque application.
    Carr AB; Larsen PE; Papazoglou E; McGlumphy E
    Int J Oral Maxillofac Implants; 1995; 10(2):167-74. PubMed ID: 7744435
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impression techniques and misfit-induced strains on implant-supported superstructures: an in vitro study.
    Cehreli MC; Akça K
    Int J Periodontics Restorative Dent; 2006 Aug; 26(4):379-85. PubMed ID: 16939020
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effect of repeated screw joint closing and opening cycles on implant prosthetic screw reverse torque and implant and screw thread morphology.
    Guzaitis KL; Knoernschild KL; Viana MA
    J Prosthet Dent; 2011 Sep; 106(3):159-69. PubMed ID: 21889002
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cementable implant crowns composed of cast superstructure frameworks luted to electroformed primary copings: an in vitro retention study.
    Di Felice R; Rappelli G; Camaioni E; Cattani M; Meyer JM; Belser UC
    Clin Oral Implants Res; 2007 Feb; 18(1):108-13. PubMed ID: 17224031
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bone strains around immediately loaded implants supporting mandibular overdentures in human cadavers.
    Akça K; Akkocaoglu M; Cömert A; Tekdemir I; Cehreli MC
    Int J Oral Maxillofac Implants; 2007; 22(1):101-9. PubMed ID: 17340903
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of stress distribution in a screw-retained implant prosthesis.
    Watanabe F; Uno I; Hata Y; Neuendorff G; Kirsch A
    Int J Oral Maxillofac Implants; 2000; 15(2):209-18. PubMed ID: 10795453
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cement fixation and screw retention: parameters of passive fit. An in vitro study of three-unit implant-supported fixed partial dentures.
    Heckmann SM; Karl M; Wichmann MG; Winter W; Graef F; Taylor TD
    Clin Oral Implants Res; 2004 Aug; 15(4):466-73. PubMed ID: 15248882
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of friction-style and spring-style mechanical torque limiting devices for dental implants.
    Vallee MC; Conrad HJ; Basu S; Seong WJ
    J Prosthet Dent; 2008 Aug; 100(2):86-92. PubMed ID: 18672124
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Wave analysis of implant screw loosening using an air cylindrical cyclic loading device.
    Lee J; Kim YS; Kim CW; Han JS
    J Prosthet Dent; 2002 Oct; 88(4):402-8. PubMed ID: 12447217
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improving the fit of implant-supported superstructures using the spark erosion technique.
    Eisenmann E; Mokabberi A; Walter MH; Freesmeyer WB
    Int J Oral Maxillofac Implants; 2004; 19(6):810-8. PubMed ID: 15623055
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Validation of strain gauges as a method of measuring precision of fit of implant bars.
    Hegde R; Lemons JE; Broome JC; McCracken MS
    Implant Dent; 2009 Apr; 18(2):151-61. PubMed ID: 19359866
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.