BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

510 related articles for article (PubMed ID: 19418882)

  • 1. Enamel bond strength of self-etch sealant with and without prior acid etching.
    Wadenya RO; Herrera M; Smith J; Mante F
    N Y State Dent J; 2009 Mar; 75(2):49-51. PubMed ID: 19418882
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Bond strength of a sealant to permanent enamel: evaluation of 3 application protocols.
    Asselin ME; Sitbon Y; Fortin D; Abelardo L; Rompre PH
    Pediatr Dent; 2009; 31(4):323-8. PubMed ID: 19722442
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Bond strength of a sealant to primary and permanent enamel: phosphoric acid versus self-etching adhesive.
    Peutzfeldt A; Nielsen LA
    Pediatr Dent; 2004; 26(3):240-4. PubMed ID: 15185805
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparative evaluation of shear bond strength of three pit and fissure sealants using conventional etch or self-etching primer.
    Dhillon JK; Pathak A
    J Indian Soc Pedod Prev Dent; 2012; 30(4):288-92. PubMed ID: 23514679
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Bond strength of 4 sealants using conventional etch and a self-etching primer.
    Al-Sarheed M
    J Dent Child (Chic); 2006; 73(1):37-41. PubMed ID: 16734312
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Shear bond strength of self-etch adhesives to enamel with additional phosphoric acid etching.
    Lührs AK; Guhr S; Schilke R; Borchers L; Geurtsen W; Günay H
    Oper Dent; 2008; 33(2):155-62. PubMed ID: 18435189
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The role of etching in bonding to enamel: a comparison of self-etching and etch-and-rinse adhesive systems.
    Erickson RL; Barkmeier WW; Latta MA
    Dent Mater; 2009 Nov; 25(11):1459-67. PubMed ID: 19665220
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The efficacy of primer on sealant shear bond strength.
    Choi JW; Drummond JL; Dooley R; Punwani I; Soh JM
    Pediatr Dent; 1997; 19(4):286-8. PubMed ID: 9200203
    [No Abstract]   [Full Text] [Related]  

  • 9. Microleakage and bond strength of sealant to primary enamel comparing air abrasion and acid etch techniques.
    Knobloch LA; Meyer T; Kerby RE; Johnston W
    Pediatr Dent; 2005; 27(6):463-9. PubMed ID: 16532886
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Shear strength of sealants placed with non-rinse conditioning compared to a conventional acid etch-rinse technique.
    Fuks AB; Eidelman E; Lewinstein I
    ASDC J Dent Child; 2002; 69(3):239-42, 233. PubMed ID: 12613304
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Length of resin tags in pit-and-fissure sealants: all-in-one self-etching adhesive vs phosphoric acid etching.
    dos Santos KT; Sundfeld RH; Garbin CA; de Alexandre RS; Sundefeld ML; Ceolim BN
    Compend Contin Educ Dent; 2008 Apr; 29(3):186-92. PubMed ID: 18468305
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Marginal microleakage of a sealant applied to permanent enamel: evaluation of 3 application protocols.
    Asselin ME; Fortin D; Sitbon Y; Rompré PH
    Pediatr Dent; 2008; 30(1):29-33. PubMed ID: 18402096
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Microtensile bond strength to ground enamel by glass-ionomers, resin-modified glass-ionomers, and resin composites used as pit and fissure sealants.
    Papacchini F; Goracci C; Sadek FT; Monticelli F; Garcia-Godoy F; Ferrari M
    J Dent; 2005 Jul; 33(6):459-67. PubMed ID: 15935265
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Shear bond strength of a sealant to contaminated-enamel surface: influence of erbium : yttrium-aluminum-garnet laser pretreatment.
    Lepri TP; Souza-Gabriel AE; Atoui JA; Palma-Dibb RG; Pécora JD; Milori Corona SA
    J Esthet Restor Dent; 2008; 20(6):386-92; discussion 393-4. PubMed ID: 19120785
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Shear Bond Strength and Microleakage of a New Self-etching/Self-adhesive Pit and Fissure Sealant.
    Schuldt C; Birlbauer S; Pitchika V; Crispin A; Hickel R; Ilie N; Kühnisch J
    J Adhes Dent; 2015 Dec; 17(6):491-7. PubMed ID: 26734672
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of shear bond strength and SEM observation of all-in-one self-etching primer used for bonding of fissure sealants.
    Al-Sarheed MA
    J Contemp Dent Pract; 2006 May; 7(2):9-16. PubMed ID: 16685290
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of sealant viscosity on the penetration of resin into etched human enamel.
    Irinoda Y; Matsumura Y; Kito H; Nakano T; Toyama T; Nakagaki H; Tsuchiya T
    Oper Dent; 2000; 25(4):274-82. PubMed ID: 11203831
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparison of six enamel treatment procedures for sealant bonding.
    Brown JR; Barkmeier WW
    Pediatr Dent; 1996; 18(1):29-31. PubMed ID: 8668566
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparative study of microleakage of a pit and fissure sealant placed after preparation by Er:YAG laser in permanent molars.
    Lupi-Pegurier L; Bertrand MF; Muller-Bolla M; Rocca JP; Bolla M
    J Dent Child (Chic); 2003; 70(2):134-8. PubMed ID: 14528774
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A comparative evaluation of shear bond strength of different pits and fissure sealants: an in vitro study.
    Singh N; Agrawal G; Subhash A; Suneela S; Barabde AS; Kumar GA
    J Contemp Dent Pract; 2013 Sep; 14(5):917-23. PubMed ID: 24685798
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 26.