These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 1941984)

  • 1. The effect of varying LED intensity on pulse oximeter accuracy.
    de Kock JP; Reynolds KJ; Tarassenko L; Moyle JT
    J Med Eng Technol; 1991; 15(3):111-5. PubMed ID: 1941984
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Experimental and clinical evaluation of a noninvasive reflectance pulse oximeter sensor.
    Takatani S; Davies C; Sakakibara N; Zurick A; Kraenzler E; Golding LR; Noon GP; Nose Y; DeBakey ME
    J Clin Monit; 1992 Oct; 8(4):257-66. PubMed ID: 1453185
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Accuracy of two pulse oximeters at low arterial hemoglobin-oxygen saturation.
    Carter BG; Carlin JB; Tibballs J; Mead H; Hochmann M; Osborne A
    Crit Care Med; 1998 Jun; 26(6):1128-33. PubMed ID: 9635666
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Accuracy of 6 Inexpensive Pulse Oximeters Not Cleared by the Food and Drug Administration: The Possible Global Public Health Implications.
    Lipnick MS; Feiner JR; Au P; Bernstein M; Bickler PE
    Anesth Analg; 2016 Aug; 123(2):338-45. PubMed ID: 27089002
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Temperature dependence of led and its theoretical effect on pulse oximetry.
    Reynolds KJ; de Kock JP; Tarassenko L; Moyle JT
    Br J Anaesth; 1991 Nov; 67(5):638-43. PubMed ID: 1751282
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Response of 10 pulse oximeters to an in vitro test system.
    Reynolds KJ; Moyle JT; Sykes MK; Hahn CE
    Br J Anaesth; 1992 Apr; 68(4):365-9. PubMed ID: 1642914
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of anemia on pulse oximeter accuracy at low saturation.
    Severinghaus JW; Koh SO
    J Clin Monit; 1990 Apr; 6(2):85-8. PubMed ID: 2352007
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Precision and accuracy of "a pocket" pulse oximeter in Mexico City].
    Torre-Bouscoulet L; Chávez-Plascencia E; Vázquez-García JC; Pérez-Padilla R
    Rev Invest Clin; 2006; 58(1):28-33. PubMed ID: 16789596
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pulse Oximetry with Two Infrared Wavelengths without Calibration in Extracted Arterial Blood.
    Yossef Hay O; Cohen M; Nitzan I; Kasirer Y; Shahroor-Karni S; Yitzhaky Y; Engelberg S; Nitzan M
    Sensors (Basel); 2018 Oct; 18(10):. PubMed ID: 30326552
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effects of motion on the performance of pulse oximeters in volunteers.
    Barker SJ; Shah NK
    Anesthesiology; 1996 Oct; 85(4):774-81. PubMed ID: 8873547
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Accuracy of the Masimo SET® LNCS neo peripheral pulse oximeter in cyanotic congenital heart disease.
    Griksaitis MJ; Scrimgeour GE; Pappachan JV; Baldock AJ
    Cardiol Young; 2016 Aug; 26(6):1183-6. PubMed ID: 26471067
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of peripheral perfusion on accuracy of pulse oximetry in children.
    Villanueva R; Bell C; Kain ZN; Colingo KA
    J Clin Anesth; 1999 Jun; 11(4):317-22. PubMed ID: 10470634
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Does the estimation of light attenuation in tissue increase the accuracy of reflectance pulse oximetry at low oxygen saturations in vivo?
    Kisch-Wedel H; Bernreuter P; Kemming G; Albert M; Zwissler B
    IEEE Trans Biomed Eng; 2009 Sep; 56(9):2271-9. PubMed ID: 19692303
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An oximeter for measuring hemoglobin concentration and oxygen content.
    Shepherd AP; Randal VT; Steinke JM; Schmalzel JL
    Am J Physiol; 1989 Nov; 257(5 Pt 2):H1705-11. PubMed ID: 2686466
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monitoring of haemoglobin oxygen saturation in healthy infants using a new generation pulse oximeter which takes motion artifacts into account.
    Meyts I; Reempts PV; Boeck KD
    Eur J Pediatr; 2002 Dec; 161(12):653-5. PubMed ID: 12447664
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Accuracy of Pulse Oximeters Intended for Hypoxemic Pediatric Patients.
    Harris BU; Char DS; Feinstein JA; Verma A; Shiboski SC; Ramamoorthy C
    Pediatr Crit Care Med; 2016 Apr; 17(4):315-20. PubMed ID: 26914626
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Potential errors in pulse oximetry. I. Pulse oximeter evaluation.
    Ralston AC; Webb RK; Runciman WB
    Anaesthesia; 1991 Mar; 46(3):202-6. PubMed ID: 2014898
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An in vivo investigation of photoplethysmographic signals and preliminary pulse oximetry estimation from the bowel using a new fiberoptic sensor.
    Hickey M; Samuels N; Randive N; Langford RM; Kyriacou PA
    Anesth Analg; 2011 May; 112(5):1104-9. PubMed ID: 21346164
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Sounds of Desaturation: A Survey of Commercial Pulse Oximeter Sonifications.
    Loeb RG; Brecknell B; Sanderson PM
    Anesth Analg; 2016 May; 122(5):1395-403. PubMed ID: 27028772
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.