206 related articles for article (PubMed ID: 19420423)
1. Computed tomography dose assessment for a 160 mm wide, 320 detector row, cone beam CT scanner.
Geleijns J; Salvadó Artells M; de Bruin PW; Matter R; Muramatsu Y; McNitt-Gray MF
Phys Med Biol; 2009 May; 54(10):3141-59. PubMed ID: 19420423
[TBL] [Abstract][Full Text] [Related]
2. Determination of the weighted CT dose index in modern multi-detector CT scanners.
Perisinakis K; Damilakis J; Tzedakis A; Papadakis A; Theocharopoulos N; Gourtsoyiannis N
Phys Med Biol; 2007 Nov; 52(21):6485-95. PubMed ID: 17951857
[TBL] [Abstract][Full Text] [Related]
3. Cone beam CT dosimetry: a unified and self-consistent approach including all scan modalities--with or without phantom motion.
Dixon RL; Boone JM
Med Phys; 2010 Jun; 37(6):2703-18. PubMed ID: 20632581
[TBL] [Abstract][Full Text] [Related]
4. Monte Carlo simulation of the dose distribution of ICRP adult reference computational phantoms for acquisitions with a 320 detector-row cone-beam CT scanner.
Salvadó M; Cros M; Joemai RM; Calzado A; Geleijns J
Phys Med; 2015 Jul; 31(5):452-62. PubMed ID: 25964128
[TBL] [Abstract][Full Text] [Related]
5. Determination of multislice computed tomography dose index (CTDI) using optically stimulated luminescence technology.
Ruan C; Yukihara EG; Clouse WJ; Gasparian PB; Ahmad S
Med Phys; 2010 Jul; 37(7):3560-8. PubMed ID: 20831063
[TBL] [Abstract][Full Text] [Related]
6. SimDoseCT: dose reporting software based on Monte Carlo simulation for a 320 detector-row cone-beam CT scanner and ICRP computational adult phantoms.
Cros M; Joemai RMS; Geleijns J; Molina D; Salvadó M
Phys Med Biol; 2017 Jul; 62(15):6304-6321. PubMed ID: 28590940
[TBL] [Abstract][Full Text] [Related]
7. Computed tomography dose index and dose length product for cone-beam CT: Monte Carlo simulations.
Kim S; Song H; Samei E; Yin FF; Yoshizumi TT
J Appl Clin Med Phys; 2011 Jan; 12(2):3395. PubMed ID: 21587186
[TBL] [Abstract][Full Text] [Related]
8. A Monte Carlo investigation of cumulative dose measurements for cone beam computed tomography (CBCT) dosimetry.
Abuhaimed A; Martin CJ; Sankaralingam M; Gentle DJ
Phys Med Biol; 2015 Feb; 60(4):1519-42. PubMed ID: 25615012
[TBL] [Abstract][Full Text] [Related]
9. Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging.
Gomà C; Ruiz A; Jornet N; Latorre A; Pallerol RM; Carrasco P; Eudaldo T; Ribas M
Med Phys; 2011 Mar; 38(3):1473-80. PubMed ID: 21520859
[TBL] [Abstract][Full Text] [Related]
10. Technical Note: Using linear and polynomial approximations to correct IEC CTDI measurements for a wide-beam CT scanner.
Weir VJ; Zhang J
Med Phys; 2019 Nov; 46(11):5360-5365. PubMed ID: 31484208
[TBL] [Abstract][Full Text] [Related]
11. Investigation of practical approaches to evaluating cumulative dose for cone beam computed tomography (CBCT) from standard CT dosimetry measurements: a Monte Carlo study.
Abuhaimed A; Martin CJ; Sankaralingam M; Gentle DJ
Phys Med Biol; 2015 Jul; 60(14):5413-38. PubMed ID: 26118740
[TBL] [Abstract][Full Text] [Related]
12. A Monte Carlo based method to estimate radiation dose from multidetector CT (MDCT): cylindrical and anthropomorphic phantoms.
DeMarco JJ; Cagnon CH; Cody DD; Stevens DM; McCollough CH; O'Daniel J; McNitt-Gray MF
Phys Med Biol; 2005 Sep; 50(17):3989-4004. PubMed ID: 16177525
[TBL] [Abstract][Full Text] [Related]
13. Concepts for dose determination in flat-detector CT.
Kyriakou Y; Deak P; Langner O; Kalender WA
Phys Med Biol; 2008 Jul; 53(13):3551-66. PubMed ID: 18552416
[TBL] [Abstract][Full Text] [Related]
14. Dosimetry methods for multi-detector computed tomography.
Gancheva M; Dyakov I; Vassileva J; Avramova-Cholakova S; Taseva D
Radiat Prot Dosimetry; 2015 Jul; 165(1-4):190-3. PubMed ID: 25889607
[TBL] [Abstract][Full Text] [Related]
15. Computed tomography dosimetry with high-resolution detectors commonly used in radiotherapy - an energy dependence study.
Liebmann M; Poppe B; von Boetticher H
J Appl Clin Med Phys; 2015 Sep; 16(5):396–407. PubMed ID: 26699294
[TBL] [Abstract][Full Text] [Related]
16. Mathematical modelling of scanner-specific bowtie filters for Monte Carlo CT dosimetry.
Kramer R; Cassola VF; Andrade ME; de Araújo MW; Brenner DJ; Khoury HJ
Phys Med Biol; 2017 Feb; 62(3):781-809. PubMed ID: 28072578
[TBL] [Abstract][Full Text] [Related]
17. Novel methods of measuring single scan dose profiles and cumulative dose in CT.
Nakonechny KD; Fallone BG; Rathee S
Med Phys; 2005 Jan; 32(1):98-109. PubMed ID: 15719960
[TBL] [Abstract][Full Text] [Related]
18. Dosimetry concepts for scanner quality assurance and tissue dose assessment in micro-CT.
Hupfer M; Kolditz D; Nowak T; Eisa F; Brauweiler R; Kalender WA
Med Phys; 2012 Feb; 39(2):658-70. PubMed ID: 22320775
[TBL] [Abstract][Full Text] [Related]
19. A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models.
Jarry G; DeMarco JJ; Beifuss U; Cagnon CH; McNitt-Gray MF
Phys Med Biol; 2003 Aug; 48(16):2645-63. PubMed ID: 12974580
[TBL] [Abstract][Full Text] [Related]
20. Validation of a Monte Carlo simulation for dose assessment in dental cone beam CT examinations.
Morant JJ; Salvadó M; Casanovas R; Hernández-Girón I; Velasco E; Calzado A
Phys Med; 2012 Jul; 28(3):200-9. PubMed ID: 21807542
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]