334 related articles for article (PubMed ID: 19422579)
21. Prospective study of axillary vein puncture with or without contrast venography for pacemaker and defibrillator lead implantation.
Burri H; Sunthorn H; Dorsaz PA; Shah D
Pacing Clin Electrophysiol; 2005 Jan; 28 Suppl 1():S280-3. PubMed ID: 15683516
[TBL] [Abstract][Full Text] [Related]
22. Use of the mechanical dilator sheath for removal of endocardial leads: a single center experience.
Aksu T; Guray U; Sen T; Durukan M; Guray Y; Demirkan B; Kisacik H
Pacing Clin Electrophysiol; 2012 May; 35(5):514-8. PubMed ID: 22353144
[TBL] [Abstract][Full Text] [Related]
23. Alternative delivery of a 4Fr lumenless pacing lead in children.
Lapage MJ; Rhee EK
Pacing Clin Electrophysiol; 2008 May; 31(5):543-7. PubMed ID: 18439166
[TBL] [Abstract][Full Text] [Related]
24. Application of intravenous electrocardiography for insertion of central veins dialysis catheters.
Beigi AA; Parvizian F; Masoudpour H
Saudi J Kidney Dis Transpl; 2009 Sep; 20(5):794-7. PubMed ID: 19736475
[TBL] [Abstract][Full Text] [Related]
25. Successful removal of a jugular implantable defibrillator lead with mechanical single-sheath technique.
Calvagna GM; Evola R; Scardace G; Valsecchi S
Pacing Clin Electrophysiol; 2012 Sep; 35(9):e258-60. PubMed ID: 21535032
[TBL] [Abstract][Full Text] [Related]
26. [Permanent pacemaker lead insertion for totally occluded subclavian vein].
Ohta T; Okumura S; Fujioka M
Kyobu Geka; 1994 Apr; 47(4):280-2. PubMed ID: 8152173
[TBL] [Abstract][Full Text] [Related]
27. A novel approach to transvenous dual-chamber pacing lead placement and cardiac defibrillator implantation after tricuspid valve replacement.
Lopez JA; Lufschanowski R
J Cardiovasc Electrophysiol; 2008 Aug; 19(8):873-5. PubMed ID: 18179526
[TBL] [Abstract][Full Text] [Related]
28. Laser-assisted lead extraction: the European experience.
Kennergren C; Bucknall CA; Butter C; Charles R; Fuhrer J; Grosfeld M; Tavernier R; Morgado TB; Mortensen P; Paul V; Richter P; Schwartz T; Wellens F;
Europace; 2007 Aug; 9(8):651-6. PubMed ID: 17597078
[TBL] [Abstract][Full Text] [Related]
29. Predictors of venous obstruction following pacemaker or implantable cardioverter-defibrillator implantation: a contrast venographic study on 100 patients admitted for generator change, lead revision, or device upgrade.
Haghjoo M; Nikoo MH; Fazelifar AF; Alizadeh A; Emkanjoo Z; Sadr-Ameli MA
Europace; 2007 May; 9(5):328-32. PubMed ID: 17369270
[TBL] [Abstract][Full Text] [Related]
30. [Double-wire technique for implanting a left ventricular venous lead in patients with complicated coronary venous anatomy].
Arbelo E; Medina A; Bolaños J; García-Quintana A; Caballero E; Delgado A; Melián F; Amador C; Suárez de Lezo J
Rev Esp Cardiol; 2007 Feb; 60(2):110-6. PubMed ID: 17338876
[TBL] [Abstract][Full Text] [Related]
31. Nontraditional surgical approaches for implantation of pacemaker and cardioverter defibrillator systems in patients with limited venous access.
Jaroszewski DE; Altemose GT; Scott LR; Srivasthan K; Devaleria PA; Lackey J; Arabia FA
Ann Thorac Surg; 2009 Jul; 88(1):112-6. PubMed ID: 19559206
[TBL] [Abstract][Full Text] [Related]
32. Intravascular lead extraction using the excimer laser: pitfalls and tips for success.
Feldtman RW
Semin Vasc Surg; 2008 Mar; 21(1):54-6. PubMed ID: 18342737
[TBL] [Abstract][Full Text] [Related]
33. [An old looped lead removal, complicated by its knotting over the active right ventricular lead - a case report].
Małecka B; Kutarski A; Pietura R; Zabek A; Bednarek J; Lelakowski J; Szczerbo-Trojanowska M
Kardiol Pol; 2008 Aug; 66(8):865-8. PubMed ID: 18803138
[TBL] [Abstract][Full Text] [Related]
34. Pacemaker implantation in patients with persistent left superior vena cava.
Lappegård KT; Prytz JF; Haug B
Heart Vessels; 2004 May; 19(3):153-4. PubMed ID: 15168065
[TBL] [Abstract][Full Text] [Related]
35. Inside-out access: a new method of lead placement for patients with central venous occlusions.
Elayi CS; Allen CL; Leung S; Lusher S; Morales GX; Wiisanen M; Aikat S; Kakavand B; Shah JS; Moliterno DJ; Gurley JC
Heart Rhythm; 2011 Jun; 8(6):851-7. PubMed ID: 21237290
[TBL] [Abstract][Full Text] [Related]
36. Epicardial and pleural lead ICD systems in children and adolescents maintain functionality over 5 years.
Tomaske M; Prêtre R; Rahn M; Bauersfeld U
Europace; 2008 Oct; 10(10):1152-6. PubMed ID: 18701602
[TBL] [Abstract][Full Text] [Related]
37. The use of a "side-wire" permanent transvenous pacing electrode for left ventricular pacing.
Walker S; Levy T; Rex S; Paul VE
Europace; 1999 Jul; 1(3):197-200. PubMed ID: 11225798
[TBL] [Abstract][Full Text] [Related]
38. Laser lead extraction: is there a learning curve?
Ghosh N; Yee R; Klein GJ; Quantz M; Novick RJ; Skanes AC; Krahn AD
Pacing Clin Electrophysiol; 2005 Mar; 28(3):180-4. PubMed ID: 15733175
[TBL] [Abstract][Full Text] [Related]
39. Techniques for transvenous leads extraction.
Bongiorni MG; Soldati E; De Lucia R; Marzilli M
Minerva Cardioangiol; 2007 Dec; 55(6):771-81. PubMed ID: 18091645
[TBL] [Abstract][Full Text] [Related]
40. Weapons development programme before the lead war.
Klug D; Modine T; Marquié C; Kacet S
Europace; 2011 Apr; 13(4):460-1. PubMed ID: 21177276
[No Abstract] [Full Text] [Related]
[Previous] [Next] [New Search]