116 related articles for article (PubMed ID: 19422600)
61. Effects of norepinephrine on kidney in a swine model of cardiopulmonary resuscitation.
Han Y; Li CS; Su ZY; Lu Y; Wang SQ
Am J Emerg Med; 2011 Sep; 29(7):731-7. PubMed ID: 20825880
[TBL] [Abstract][Full Text] [Related]
62. [The PiCCO system with brachial-axillary artery access in hemodynamic monitoring during surgery of abdominal aortic aneurysm].
Antonini M; Meloncelli S; Dantimi C; Tosti S; Ciotti L; Gasparetto A
Minerva Anestesiol; 2001 Jun; 67(6):447-56. PubMed ID: 11533543
[TBL] [Abstract][Full Text] [Related]
63. Global end-diastolic volume acquired by transpulmonary thermodilution depends on age and gender in awake and spontaneously breathing patients.
Wolf S; Riess A; Landscheidt JF; Lumenta CB; Friederich P; Schürer L
Crit Care; 2009; 13(6):R202. PubMed ID: 20003415
[TBL] [Abstract][Full Text] [Related]
64. [The effect of blood volume change on the accuracy of pulse contour cardiac output].
Yao D; Xu J; Li C; Fu Y; Li Y; Tan D; Shao S; Liu D; Zhu H; Guo S; Yu X
Zhonghua Wai Ke Za Zhi; 2015 Jul; 53(7):547-52. PubMed ID: 26359081
[TBL] [Abstract][Full Text] [Related]
65. Assessing intravascular volume by difference in pulse pressure in pigs submitted to graded hemorrhage.
Pestel GJ; Hiltebrand LB; Fukui K; Cohen D; Hager H; Kurz AM
Shock; 2006 Oct; 26(4):391-5. PubMed ID: 16980887
[TBL] [Abstract][Full Text] [Related]
66. Cardiovascular effects of vasopressors in halothane-anesthetized dogs before and after hemorrhage.
Curtis MB; Bednarski RM; Majors L
Am J Vet Res; 1989 Nov; 50(11):1859-65. PubMed ID: 2619116
[TBL] [Abstract][Full Text] [Related]
67. Functional haemodynamic monitoring: The value of SVV as measured by the LiDCORapid™ in predicting fluid responsiveness in high risk vascular surgical patients.
Willars C; Dada A; Hughes T; Green D
Int J Surg; 2012; 10(3):148-52. PubMed ID: 22330275
[TBL] [Abstract][Full Text] [Related]
68. Less invasive indicators of changes in thermodilution cardiac output by ventilatory changes after cardiac surgery.
Breukers RM; Willems JH; de Wilde R; Jansen JR; Groeneveld AJ
Eur J Anaesthesiol; 2009 Oct; 26(10):863-7. PubMed ID: 19390444
[TBL] [Abstract][Full Text] [Related]
69. Effect of maleimide-polyethylene glycol hemoglobin (MP4) on hemodynamics and acid-base status after uncontrolled hemorrhage in anesthetized swine: comparison with crystalloid and blood.
Young MA; Riddez L; Kjellström BT; Winslow RM
J Trauma; 2007 Dec; 63(6):1234-44. PubMed ID: 18212644
[TBL] [Abstract][Full Text] [Related]
70. Efficacy of functional hemodynamic parameters in predicting fluid responsiveness with pulse power analysis in surgical patients.
Cecconi M; Monti G; Hamilton MA; Puntis M; Dawson D; Tuccillo ML; Della Rocca G; Grounds RM; Rhodes A
Minerva Anestesiol; 2012 May; 78(5):527-33. PubMed ID: 22534733
[TBL] [Abstract][Full Text] [Related]
71. Estimation of errors in determining intrathoracic blood volume using the single transpulmonary thermal dilution technique in hypovolemic shock.
Nirmalan M; Willard TM; Edwards DJ; Little RA; Dark PM
Anesthesiology; 2005 Oct; 103(4):805-12. PubMed ID: 16192773
[TBL] [Abstract][Full Text] [Related]
72. Cardiovascular effects of vasopressors in isoflurane-anesthetized dogs before and after hemorrhage.
Curtis MB; Bednarski RM; Majors L
Am J Vet Res; 1989 Nov; 50(11):1866-71. PubMed ID: 2619117
[TBL] [Abstract][Full Text] [Related]
73. Low-volume resuscitation with a polymerized bovine hemoglobin-based oxygen-carrying solution (HBOC-201) provides adequate tissue oxygenation for survival in a porcine model of controlled hemorrhage.
York GB; Eggers JS; Smith DL; Jenkins DH; McNeil JD; Mueller D; Josephs JD; Kerby JD
J Trauma; 2003 Nov; 55(5):873-85. PubMed ID: 14608160
[TBL] [Abstract][Full Text] [Related]
74. A systematic database-derived approach to improve indexation of transpulmonary thermodilution-derived global end-diastolic volume.
Huber W; Mair S; Götz SQ; Tschirdewahn J; Frank J; Höllthaler J; Phillip V; Schmid RM; Saugel B
J Clin Monit Comput; 2017 Feb; 31(1):143-151. PubMed ID: 26831297
[TBL] [Abstract][Full Text] [Related]
75. Estimation of errors in determining intrathoracic blood volume using thermal dilution in pigs with acute lung injury and haemorrhage.
Nirmalan M; Niranjan M; Willard T; Edwards JD; Little RA; Dark PM
Br J Anaesth; 2004 Oct; 93(4):546-51. PubMed ID: 15277298
[TBL] [Abstract][Full Text] [Related]
76. Standardized blood volume changes monitored by capnodynamic hemodynamic variables: An experimental comparative study in pigs.
Karlsson J; Hallbäck M; Svedmyr A; Lönnqvist PA; Wallin M
Acta Anaesthesiol Scand; 2023 Aug; 67(7):953-963. PubMed ID: 37184945
[TBL] [Abstract][Full Text] [Related]
77. Continuous Estimation of Acute Changes in Preload Using Epicardially Attached Accelerometers.
Krogh MR; Halvorsen PS; Grymyr OHN; Bergsland J; Elle OJ; Fosse E; Remme EW
IEEE Trans Biomed Eng; 2021 Jul; 68(7):2067-2075. PubMed ID: 32866091
[TBL] [Abstract][Full Text] [Related]
78. Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study.
Dahl MK; Vistisen ST; Koefoed-Nielsen J; Larsson A
Crit Care; 2009; 13(2):R39. PubMed ID: 19302700
[TBL] [Abstract][Full Text] [Related]
79. Aortic volume determines global end-diastolic volume measured by transpulmonary thermodilution.
Akohov A; Barner C; Grimmer S; Francis RC; Wolf S
Intensive Care Med Exp; 2020 Jan; 8(1):1. PubMed ID: 31897796
[TBL] [Abstract][Full Text] [Related]
80. Relationship between pulse pressure variation and stroke volume variation with changes in cardiac index during hypotension in patients undergoing major spine surgeries in prone position - A prospective observational study.
Arumugam R; Thomas S; Jacob NSM; Nadaraj A; George SP; Singh G
J Anaesthesiol Clin Pharmacol; 2022; 38(4):553-559. PubMed ID: 36778833
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]