1. Accuracy requirements for head and neck intensity-modulated radiation therapy based on observed dose response of the major salivary glands. Kapanen M; Collan J; Saarilahti K; Heikkonen J; Kairemo K; Tenhunen M Radiother Oncol; 2009 Oct; 93(1):109-14. PubMed ID: 19435641 [TBL] [Abstract][Full Text] [Related]
2. Evaluation of salivary gland function after treatment of head-and-neck tumors with intensity-modulated radiotherapy by quantitative pertechnetate scintigraphy. Münter MW; Karger CP; Hoffner SG; Hof H; Thilmann C; Rudat V; Nill S; Wannenmacher M; Debus J Int J Radiat Oncol Biol Phys; 2004 Jan; 58(1):175-84. PubMed ID: 14697436 [TBL] [Abstract][Full Text] [Related]
3. Intensity-modulated radiotherapy or volumetric-modulated arc therapy in patients with head and neck cancer: Focus on salivary glands dosimetry. Vallard A; Guy JB; Mengue Ndong S; Vial N; Rivoirard R; Auberdiac P; Méry B; Langrand-Escure J; Espenel S; Moncharmont C; Ben Mrad M; Diao P; Goyet D; Magné N Head Neck; 2016 Jul; 38(7):1028-34. PubMed ID: 26855006 [TBL] [Abstract][Full Text] [Related]
4. Changes in salivary gland function after radiotherapy of head and neck tumors measured by quantitative pertechnetate scintigraphy: comparison of intensity-modulated radiotherapy and conventional radiation therapy with and without Amifostine. Münter MW; Hoffner S; Hof H; Herfarth KK; Haberkorn U; Rudat V; Huber P; Debus J; Karger CP Int J Radiat Oncol Biol Phys; 2007 Mar; 67(3):651-9. PubMed ID: 17175118 [TBL] [Abstract][Full Text] [Related]
6. Prospective investigation and literature review of tolerance dose on salivary glands using quantitative salivary gland scintigraphy in the intensity-modulated radiotherapy era. Lee SW; Kang KW; Wu HG Head Neck; 2016 Apr; 38 Suppl 1():E1746-55. PubMed ID: 26875880 [TBL] [Abstract][Full Text] [Related]
7. Dosimetry audit for a multi-centre IMRT head and neck trial. Clark CH; Hansen VN; Chantler H; Edwards C; James HV; Webster G; Miles EA; Guerrero Urbano MT; Bhide SA; Bidmead AM; Nutting CM; Radiother Oncol; 2009 Oct; 93(1):102-8. PubMed ID: 19596158 [TBL] [Abstract][Full Text] [Related]
8. Scintigraphy in prediction of the salivary gland function after gland-sparing intensity modulated radiation therapy for head and neck cancer. Tenhunen M; Collan J; Kouri M; Kangasmäki A; Heikkonen J; Kairemo K; Mäkitie A; Joensuu H; Saarilahti K Radiother Oncol; 2008 May; 87(2):260-7. PubMed ID: 18329118 [TBL] [Abstract][Full Text] [Related]
9. Impact of salivary gland dosimetry on post-IMRT recovery of saliva output and xerostomia grade for head-and-neck cancer patients treated with or without contralateral submandibular gland sparing: a longitudinal study. Wang ZH; Yan C; Zhang ZY; Zhang CP; Hu HS; Tu WY; Kirwan J; Mendenhall WM Int J Radiat Oncol Biol Phys; 2011 Dec; 81(5):1479-87. PubMed ID: 20934262 [TBL] [Abstract][Full Text] [Related]
10. Preservation of oral health-related quality of life and salivary flow rates after inverse-planned intensity- modulated radiotherapy (IMRT) for head-and-neck cancer. Parliament MB; Scrimger RA; Anderson SG; Kurien EC; Thompson HK; Field GC; Hanson J Int J Radiat Oncol Biol Phys; 2004 Mar; 58(3):663-73. PubMed ID: 14967418 [TBL] [Abstract][Full Text] [Related]
11. Radiation-induced volume changes in parotid and submandibular glands in patients with head and neck cancer receiving postoperative radiotherapy: a longitudinal study. Wang ZH; Yan C; Zhang ZY; Zhang CP; Hu HS; Kirwan J; Mendenhall WM Laryngoscope; 2009 Oct; 119(10):1966-74. PubMed ID: 19688858 [TBL] [Abstract][Full Text] [Related]
12. Comparing 3DCRT and inversely optimized IMRT planning for head and neck cancer: equivalence between step-and-shoot and sliding window techniques. Longobardi B; De Martin E; Fiorino C; Dell'oca I; Broggi S; Cattaneo GM; Calandrino R Radiother Oncol; 2005 Nov; 77(2):148-56. PubMed ID: 16260056 [TBL] [Abstract][Full Text] [Related]
13. [Quantitative and qualitative investigations of salivary gland function in dependence on irradiation dose and volume for reduction of xerostomia in patients with head-and-neck cancer]. Kuhnt T; Jirsak N; Müller AC; Pelz T; Gernhardt C; Schaller HG; Janich M; Gerlach R; Dunst J Strahlenther Onkol; 2005 Aug; 181(8):520-8. PubMed ID: 16044220 [TBL] [Abstract][Full Text] [Related]
14. Scintigraphic assessment of salivary function after intensity-modulated radiotherapy for head and neck cancer: correlations with parotid dose and quality of life. Chen WC; Lai CH; Lee TF; Hung CH; Liu KC; Tsai MF; Wang WH; Chen H; Fang FM; Chen MF Oral Oncol; 2013 Jan; 49(1):42-8. PubMed ID: 22854066 [TBL] [Abstract][Full Text] [Related]
15. Adaptive planning in intensity-modulated radiation therapy for head and neck cancers: single-institution experience and clinical implications. Ahn PH; Chen CC; Ahn AI; Hong L; Scripes PG; Shen J; Lee CC; Miller E; Kalnicki S; Garg MK Int J Radiat Oncol Biol Phys; 2011 Jul; 80(3):677-85. PubMed ID: 20619553 [TBL] [Abstract][Full Text] [Related]
16. Salivary gland sparing and improved target irradiation by conformal and intensity modulated irradiation of head and neck cancer. Eisbruch A; Ship JA; Dawson LA; Kim HM; Bradford CR; Terrell JE; Chepeha DB; Teknos TN; Hogikyan ND; Anzai Y; Marsh LH; Ten Haken RK; Wolf GT World J Surg; 2003 Jul; 27(7):832-7. PubMed ID: 14509515 [TBL] [Abstract][Full Text] [Related]
17. 3D-conformal-intensity modulated radiotherapy with compensators for head and neck cancer: clinical results of normal tissue sparing. Wendt TG; Abbasi-Senger N; Salz H; Pinquart I; Koscielny S; Przetak SM; Wiezorek T Radiat Oncol; 2006 Jun; 1():18. PubMed ID: 16790059 [TBL] [Abstract][Full Text] [Related]
18. Submandibular gland-sparing intensity modulated radiotherapy in the treatment of head and neck cancer: sites of locoregional relapse and survival. Collan J; Kapanen M; Mäkitie A; Nyman H; Joensuu H; Tenhunen M; Saarilahti K Acta Oncol; 2012 Jul; 51(6):735-42. PubMed ID: 22150115 [TBL] [Abstract][Full Text] [Related]
19. The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy. Hong TS; Tomé WA; Chappell RJ; Chinnaiyan P; Mehta MP; Harari PM Int J Radiat Oncol Biol Phys; 2005 Mar; 61(3):779-88. PubMed ID: 15708257 [TBL] [Abstract][Full Text] [Related]
20. Near Real-Time Assessment of Anatomic and Dosimetric Variations for Head and Neck Radiation Therapy via Graphics Processing Unit-based Dose Deformation Framework. Qi XS; Santhanam A; Neylon J; Min Y; Armstrong T; Sheng K; Staton RJ; Pukala J; Pham A; Low DA; Lee SP; Steinberg M; Manon R; Chen AM; Kupelian P Int J Radiat Oncol Biol Phys; 2015 Jun; 92(2):415-22. PubMed ID: 25847607 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]