These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 19436366)

  • 21. Enhanced visualization of choroidal vessels using ultrahigh resolution ophthalmic OCT at 1050 nm.
    Povazay B; Bizheva K; Hermann B; Unterhuber A; Sattmann H; Fercher A; Drexler W; Schubert C; Ahnelt P; Mei M; Holzwarth R; Wadsworth W; Knight J; Russell PS
    Opt Express; 2003 Aug; 11(17):1980-6. PubMed ID: 19466083
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Compact, broad-bandwidth fiber laser for sub-2-microm axial resolution optical coherence tomography in the 1300-nm wavelength region.
    Bizheva K; Povazay B; Hermann B; Sattmann H; Drexler W; Mei M; Holzwarth R; Hoelzenbein T; Wacheck V; Pehamberger H
    Opt Lett; 2003 May; 28(9):707-9. PubMed ID: 12747714
    [TBL] [Abstract][Full Text] [Related]  

  • 23. In vivo ultrahigh-resolution optical coherence tomography.
    Drexler W; Morgner U; Kärtner FX; Pitris C; Boppart SA; Li XD; Ippen EP; Fujimoto JG
    Opt Lett; 1999 Sep; 24(17):1221-3. PubMed ID: 18073990
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Three-dimensional retinal imaging with high-speed ultrahigh-resolution optical coherence tomography.
    Wojtkowski M; Srinivasan V; Fujimoto JG; Ko T; Schuman JS; Kowalczyk A; Duker JS
    Ophthalmology; 2005 Oct; 112(10):1734-46. PubMed ID: 16140383
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Three-dimensional and C-mode OCT imaging with a compact, frequency swept laser source at 1300 nm.
    Huber R; Wojtkowski M; Fujimoto JG; Jiang JY; Cable AE
    Opt Express; 2005 Dec; 13(26):10523-38. PubMed ID: 19503267
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Frequency-doubled DBR-tapered diode laser for direct pumping of Ti:sapphire lasers generating sub-20 fs pulses.
    Müller A; Jensen OB; Unterhuber A; Le T; Stingl A; Hasler KH; Sumpf B; Erbert G; Andersen PE; Petersen PM
    Opt Express; 2011 Jun; 19(13):12156-63. PubMed ID: 21716452
    [TBL] [Abstract][Full Text] [Related]  

  • 27. 102-nm, 44.5-MHz inertial-free swept source by mode-locked fiber laser and time stretch technique for optical coherence tomography.
    Kang J; Feng P; Wei X; Lam EY; Tsia KK; Wong KKY
    Opt Express; 2018 Feb; 26(4):4370-4381. PubMed ID: 29475287
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Continuum generation in a novel photonic crystal fiber for ultrahigh resolution optical coherence tomography at 800 nm and 1300 nm.
    Aguirre A; Nishizawa N; Fujimoto J; Seitz W; Lederer M; Kopf D
    Opt Express; 2006 Feb; 14(3):1145-60. PubMed ID: 19503436
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation.
    Wojtkowski M; Srinivasan V; Ko T; Fujimoto J; Kowalczyk A; Duker J
    Opt Express; 2004 May; 12(11):2404-22. PubMed ID: 19475077
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Ultrahigh-resolution optical coherence tomography/angiography with an economic and compact supercontinuum laser.
    Wang TA; Chan MC; Lee HC; Lee CY; Tsai MT
    Biomed Opt Express; 2019 Nov; 10(11):5687-5702. PubMed ID: 31799040
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Imaging of the lens capsule with an ultrahigh-resolution spectral optical coherence tomography prototype based on a femtosecond laser.
    Kaluzny BJ; Gora M; Karnowski K; Grulkowski I; Kowalczyk A; Wojtkowski M
    Br J Ophthalmol; 2010 Mar; 94(3):275-7. PubMed ID: 20215371
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Ultrahigh resolution all-reflective optical coherence tomography system with a compact fiber-based supercontinuum source.
    Kieu KQ; Klein J; Evans A; Barton JK; Peyghambarian N
    J Biomed Opt; 2011 Oct; 16(10):106004. PubMed ID: 22029351
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Optimal operational conditions for supercontinuum-based ultrahigh-resolution endoscopic OCT imaging.
    Yuan W; Mavadia-Shukla J; Xi J; Liang W; Yu X; Yu S; Li X
    Opt Lett; 2016 Jan; 41(2):250-3. PubMed ID: 26766686
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Development of a high power supercontinuum source in the 1.7 μm wavelength region for highly penetrative ultrahigh-resolution optical coherence tomography.
    Kawagoe H; Ishida S; Aramaki M; Sakakibara Y; Omoda E; Kataura H; Nishizawa N
    Biomed Opt Express; 2014 Mar; 5(3):932-43. PubMed ID: 24688825
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Impact of enhanced resolution, speed and penetration on three-dimensional retinal optical coherence tomography.
    Povazay B; Hofer B; Torti C; Hermann B; Tumlinson AR; Esmaeelpour M; Egan CA; Bird AC; Drexler W
    Opt Express; 2009 Mar; 17(5):4134-50. PubMed ID: 19259251
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Comparison of ultrahigh- and standard-resolution optical coherence tomography for imaging macular pathology.
    Ko TH; Fujimoto JG; Schuman JS; Paunescu LA; Kowalevicz AM; Hartl I; Drexler W; Wollstein G; Ishikawa H; Duker JS
    Ophthalmology; 2005 Nov; 112(11):1922.e1-15. PubMed ID: 16183127
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Ultrahigh resolution optical biopsy with endoscopic optical coherence tomography.
    Herz P; Chen Y; Aguirre A; Fujimoto J; Mashimo H; Schmitt J; Koski A; Goodnow J; Petersen C
    Opt Express; 2004 Jul; 12(15):3532-42. PubMed ID: 19483882
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Ultrahigh-resolution and 3-dimensional optical coherence tomography ex vivo imaging of the large and small intestines.
    Hsiung PL; Pantanowitz L; Aguirre AD; Chen Y; Phatak D; Ko TH; Bourquin S; Schnitt SJ; Raza S; Connolly JL; Mashimo H; Fujimoto JG
    Gastrointest Endosc; 2005 Oct; 62(4):561-74. PubMed ID: 16185971
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Ultrawideband photonic crystal fiber coupler for multiband optical imaging system.
    Ryu SY; Choi HY; Choi ES; Tomov I; Chen Z; Lee BH
    Appl Opt; 2010 Apr; 49(10):1986-90. PubMed ID: 20357885
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Electrically pumped continuous-wave O-band quantum-dot superluminescent diode on silicon.
    Lu Y; Cao V; Liao M; Li W; Tang M; Li A; Smowton P; Seeds A; Liu H; Chen S
    Opt Lett; 2020 Oct; 45(19):5468-5471. PubMed ID: 33001927
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.