These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
8. Cavitation Suppression of Bileaflet Mechanical Heart Valves. Qian JY; Gao ZX; Li WQ; Jin ZJ Cardiovasc Eng Technol; 2020 Dec; 11(6):783-794. PubMed ID: 32918244 [TBL] [Abstract][Full Text] [Related]
9. Development of artificial neural network-based algorithms for the classification of bileaflet mechanical heart valve sounds. Bagno A; Licciardello C; Tarzia V; Bottio T; Pengo V; Gerosa G Int J Artif Organs; 2012 Apr; 35(4):279-87. PubMed ID: 22505205 [TBL] [Abstract][Full Text] [Related]
10. Closing click of St Jude Medical and Duromedics Edwards bileaflet valves: complaints created by valve noise and their relation to sound pressure and hearing level. Moritz A; Steinseifer U; Kobina G; Neuwirth-Riedl K; Wolters H; Reul H; Wolner E Eur Heart J; 1991 Jun; 12(6):673-9. PubMed ID: 1860467 [TBL] [Abstract][Full Text] [Related]
12. The Apex bileaflet mechanical heart valve. Mohammadi H; Bhullar A J Med Eng Technol; 2021 Jan; 45(1):41-51. PubMed ID: 33448912 [TBL] [Abstract][Full Text] [Related]
13. [Application and comparison of continuous wavelet transform and matching pursuit method in analyzing phonocardiographic signals]. Zhang Z; Liu J; Tang Y; Wang W Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Aug; 25(4):756-61. PubMed ID: 18788274 [TBL] [Abstract][Full Text] [Related]
15. Noise levels of closing sounds in vivo are equal for different bileaflet mechanical heart valves. Johansen P; Hansen SB; Hasenkam JM; Nygaard H J Heart Valve Dis; 2003 Nov; 12(6):764-71. PubMed ID: 14658819 [TBL] [Abstract][Full Text] [Related]
16. Wavelet transforms in the analysis of mechanical heart valve cavitation. Herbertson LH; Reddy V; Manning KB; Welz JP; Fontaine AA; Deutsch S J Biomech Eng; 2006 Apr; 128(2):217-22. PubMed ID: 16524333 [TBL] [Abstract][Full Text] [Related]
17. Automatic measure of the split in the second cardiac sound by using the wavelet transform technique. Debbal SM; Bereksi-Reguig F Comput Biol Med; 2007 Mar; 37(3):269-76. PubMed ID: 16574092 [TBL] [Abstract][Full Text] [Related]
18. Mechanical valve evaluation with four-dimensional computed tomography. Numata S; Tsutsumi Y; Monta O; Yamazaki S; Seo H; Yoshida S; Samura T; Ohashi H J Heart Valve Dis; 2013 Nov; 22(6):837-42. PubMed ID: 24597406 [TBL] [Abstract][Full Text] [Related]
19. In vitro sound spectral analysis of prosthetic heart valves by mock circulatory system. Kim SH; Chang BC; Tack G; Huh JM; Kang MS; Cho BK; Park YH Yonsei Med J; 1994 Sep; 35(3):271-8. PubMed ID: 7975736 [TBL] [Abstract][Full Text] [Related]
20. Numerical comparison of the closing dynamics of a new trileaflet and a bileaflet mechanical aortic heart valve. Li CP; Lu PC J Artif Organs; 2012 Dec; 15(4):364-74. PubMed ID: 22692363 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]