These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

76 related articles for article (PubMed ID: 1944199)

  • 1. [Development of wearable artificial endocrine pancreas--problems awaiting solutions for long-term clinical application].
    Shichiri M
    Nihon Geka Gakkai Zasshi; 1991 Sep; 92(9):1253-7. PubMed ID: 1944199
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Design and development strategy for wearable and implantable artificial endocrine pancreas].
    Shichiri M; Nishida K
    Nihon Rinsho; 1999 Mar; 57(3):719-25. PubMed ID: 10199159
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An artificial endocrine pancreas--problems awaiting solution for long-term clinical applications of a glucose sensor.
    Shichiri M; Fukushima H; Sakakida M; Kajiwara K; Hashiguchi Y
    Front Med Biol Eng; 1991; 3(4):283-92. PubMed ID: 1799562
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Closed-loop subcutaneous insulin infusion algorithm with a short-acting insulin analog for long-term clinical application of a wearable artificial endocrine pancreas.
    Shimoda S; Nishida K; Sakakida M; Konno Y; Ichinose K; Uehara M; Nowak T; Shichiri M
    Front Med Biol Eng; 1997; 8(3):197-211. PubMed ID: 9444512
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The development of wearable-type artificial endocrine pancreas and its usefulness in glycaemic control of human diabetes mellitus.
    Shichiri M; Kawamori R; Hakui N; Asakawa N; Yamasaki Y; Abe H
    Biomed Biochim Acta; 1984; 43(5):561-8. PubMed ID: 6477542
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Long-term application of wearable artificial endocrine pancreas--closed-loop intravenous vs subcutaneous insulin infusion.
    Shichiri M; Kawamori R; Goriya Y; Yamasaki Y; Nomura M; Asakawa N; Kubota M; Kamada T
    Life Support Syst; 1985; 3 Suppl 1():583-7. PubMed ID: 3916624
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Strict glycemic control in diabetic dogs with closed-loop intraperitoneal insulin infusion algorithm designed for an artificial endocrine pancreas.
    Matsuo Y; Shimoda S; Sakakida M; Nishida K; Sekigami T; Ichimori S; Ichinose K; Shichiri M; Araki E
    J Artif Organs; 2003; 6(1):55-63. PubMed ID: 14598126
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The development of artificial endocrine pancreas. From bedside-, wearable-type to implantable one.
    Shichiri M; Kawamori R; Yamasaki Y
    Med Prog Technol; 1987; 12(1-2):39-50. PubMed ID: 3627019
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Long-term clinical application of wearable artificial endocrine pancreas].
    Sakakida M; Nishida K; Shimoda S; Matsuo Y; Araki E; Shichiri M
    Nihon Rinsho; 2002 Sep; 60 Suppl 9():613-9. PubMed ID: 12387059
    [No Abstract]   [Full Text] [Related]  

  • 10. Enhanced, simplified glucose sensors: long-term clinical application of wearable artificial endocrine pancreas.
    Shichiri M; Sakakida M; Nishida K; Shimoda S
    Artif Organs; 1998 Jan; 22(1):32-42. PubMed ID: 9456224
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Artificial and bioartificial pancreas for the treatment of diabetes mellitus].
    Reach G
    Diabete Metab; 1994; 20(2 Pt 2):183-93. PubMed ID: 8001705
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Recent advances in continuous glucose monitoring.
    Freckmann G; Kalatz B; Pfeiffer B; Hoss U; Haug C
    Exp Clin Endocrinol Diabetes; 2001; 109 Suppl 2():S347-57. PubMed ID: 11460583
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Closed-loop glycemic control with a wearable artificial endocrine pancreas. Variations in daily insulin requirements to glycemic response.
    Shichiri M; Kawamori R; Hakui N; Yamasaki Y; Abe H
    Diabetes; 1984 Dec; 33(12):1200-2. PubMed ID: 6389235
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Artificial endocrine pancreas and optimal blood glucose regulation in diabetic patients--from bedside-type to wearable-type.
    Shichiri M; Kishikawa H; Sakakida M; Kajiwara K; Hashiguchi Y; Nishida K; Uemura T; Konno Y; Ichinose K
    Diabetes Res Clin Pract; 1994 Oct; 24 Suppl():S251-9. PubMed ID: 7859615
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [From external to implantable insulin pump, can we close the loop?].
    Renard E; Costalat G; Bringer J
    Diabetes Metab; 2002 Sep; 28(4 Pt 2):2S19-2S25. PubMed ID: 12442060
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Closing the loop.
    Dassau E; Atlas E; Phillip M
    Int J Clin Pract Suppl; 2010 Feb; (166):20-5. PubMed ID: 20377660
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell.
    Abel P; Müller A; Fischer U
    Biomed Biochim Acta; 1984; 43(5):577-84. PubMed ID: 6477543
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Controlled drug delivery in the treatment of diabetes mellitus.
    Irsigler K; Kritz H; Lovett RG
    Crit Rev Ther Drug Carrier Syst; 1985; 1(3):189-280. PubMed ID: 3912064
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Continuous postoperative blood glucose monitoring and control by artificial pancreas in patients having pancreatic resection: a prospective randomized clinical trial.
    Okabayashi T; Nishimori I; Yamashita K; Sugimoto T; Maeda H; Yatabe T; Kohsaki T; Kobayashi M; Hanazaki K
    Arch Surg; 2009 Oct; 144(10):933-7. PubMed ID: 19841361
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Wearable artificial endocrine pancrease with needle-type glucose sensor.
    Shichiri M; Kawamori R; Yamasaki Y; Hakui N; Abe H
    Lancet; 1982 Nov; 2(8308):1129-31. PubMed ID: 6128452
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.