BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

576 related articles for article (PubMed ID: 19451854)

  • 1. The effect of syringe size on reliability and safety of low-flow infusions.
    Neal D; Lin JA
    Pediatr Crit Care Med; 2009 Sep; 10(5):592-6. PubMed ID: 19451854
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of syringe size on the performance of infusion pumps at low flow rates.
    Schmidt N; Saez C; Seri I; Maturana A
    Pediatr Crit Care Med; 2010 Mar; 11(2):282-6. PubMed ID: 19935442
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps.
    Neff SB; Neff TA; Gerber S; Weiss MM
    Eur J Anaesthesiol; 2007 Jul; 24(7):602-8. PubMed ID: 17261217
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prolonged time to alarm in infusion devices operated at low flow rates.
    Ilan R; Fowler RA; Ferguson ND; Parshuram CS; Friedrich JO; Lapinsky SE; Biason R; Pinto R; Etchells EE
    Crit Care Med; 2008 Oct; 36(10):2763-5. PubMed ID: 18766111
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Connecting multiple low-flow intravenous infusions in the newborn: problems and possible solutions.
    Levi DS; Peterson N; Shah SD; Rakholia B; Haught A; Carman G
    Pediatr Crit Care Med; 2010 Mar; 11(2):275-81. PubMed ID: 20068501
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Syringe pumps take too long to give occlusion alarm.
    Dönmez A; Araz C; Kayhan Z
    Paediatr Anaesth; 2005 Apr; 15(4):293-6. PubMed ID: 15787919
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An analysis of drug delivery dynamics via a pediatric central venous infusion system: quantification of delays in achieving intended doses.
    Bartels K; Moss DR; Peterfreund RA
    Anesth Analg; 2009 Oct; 109(4):1156-61. PubMed ID: 19762743
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Syringe size and flow rate affect drug delivery from syringe pumps.
    Weiss M; Hug MI; Neff T; Fischer J
    Can J Anaesth; 2000 Oct; 47(10):1031-5. PubMed ID: 11032282
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Amount of accidental flush by syringe pump due to inappropriate release of occluded intravenous line.
    Kawakami H; Miyashita T; Yanaizumi R; Mihara T; Sato H; Kariya T; Mizuno Y; Goto T
    Technol Health Care; 2013; 21(6):581-6. PubMed ID: 24225409
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Syringe Pump Performance Maintained with IV Filter Use During Low Flow Rate Delivery for Pediatric Patients.
    Chau DF; Vasilopoulos T; Schoepf M; Zhang C; Fahy BG
    Anesth Analg; 2016 Sep; 123(3):705-14. PubMed ID: 27074895
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Hypoglycemia caused by siphoning of an insulin infusion.
    Vanelderen PJ; Soetens FM; Soetens MA; Janssen HJ; De Wolf AM
    J Clin Anesth; 2007 Jun; 19(4):251-5. PubMed ID: 17572318
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intravenous infusions in hyperbaric chambers: effect of compression on syringe function.
    Hopson AS; Greenstein A
    Anaesthesia; 2007 Jun; 62(6):602-4. PubMed ID: 17506740
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Performance of modern syringe infusion pump assemblies at low infusion rates in the perioperative setting.
    Baeckert M; Batliner M; Grass B; Buehler PK; Daners MS; Meboldt M; Weiss M
    Br J Anaesth; 2020 Feb; 124(2):173-182. PubMed ID: 31864721
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Factors altering low-flow drug delivery using syringe pumps: Consequences on vasoactive drug infusion in preterm infant].
    Rakza T; Richard A; Lelieur AC; Villaume I; Huyghe A; Nempont C; Storme L
    Arch Pediatr; 2005 May; 12(5):548-54. PubMed ID: 15885544
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparison of infusion devices at 1 ml/hr.
    Wood BR; Huddleston K; Kolm P
    Neonatal Intensive Care; 1993; 6(3):20-2. PubMed ID: 10148553
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Lag times to steady state drug delivery by continuous intravenous infusion: direct comparison of peristaltic and syringe pump performance identifies contributions from infusion system dead volume and pump startup characteristics.
    Gibson LE; Knudsen AS; Arney D; Deng H; Sims NM; Peterfreund RA
    J Clin Monit Comput; 2022 Oct; 36(5):1489-1498. PubMed ID: 34878612
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of changes in syringe driver height on flow: a small quantitative study.
    Donald AI; Chinthamuneedi MP; Spearritt D
    Crit Care Resusc; 2007 Jun; 9(2):143-7. PubMed ID: 17536981
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Cost and acceptability of three syringe-pump infusion systems.
    Johnson MS; Pesko LJ; Wood CF; Reinders TP
    Am J Hosp Pharm; 1990 Aug; 47(8):1794-8. PubMed ID: 2389788
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Syringe infusion pumps with dose error reduction systems.
    Health Devices; 2008 Feb; 37(2):33-51. PubMed ID: 18773865
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Pressure build-up in 2 rate-controlled syringe infusion pumps].
    Gerlif C
    Ugeskr Laeger; 1994 Apr; 156(15):2236-9. PubMed ID: 8016950
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 29.