164 related articles for article (PubMed ID: 19464625)
1. Continuous arterial pressure waveform-based cardiac output using the FloTrac/Vigileo: a review and meta-analysis.
Mayer J; Boldt J; Poland R; Peterson A; Manecke GR
J Cardiothorac Vasc Anesth; 2009 Jun; 23(3):401-6. PubMed ID: 19464625
[No Abstract] [Full Text] [Related]
2. Comparison of uncalibrated arterial pressure waveform analysis with continuous thermodilution cardiac output measurements in patients undergoing elective off-pump coronary artery bypass surgery.
Jeong YB; Kim TH; Roh YJ; Choi IC; Suh JH
J Cardiothorac Vasc Anesth; 2010 Oct; 24(5):767-71. PubMed ID: 20399114
[TBL] [Abstract][Full Text] [Related]
3. The accuracy of the Vigileo/FloTrac continuous cardiac output monitor.
Zimmermann A; Kufner C; Hofbauer S; Steinwendner J; Hitzl W; Fritsch G; Schistek R; Kirnbauer M; Pauser G
J Cardiothorac Vasc Anesth; 2008 Jun; 22(3):388-93. PubMed ID: 18503926
[TBL] [Abstract][Full Text] [Related]
4. Cardiac output derived from arterial pressure waveform.
Mayer J; Suttner S
Curr Opin Anaesthesiol; 2009 Dec; 22(6):804-8. PubMed ID: 19773648
[TBL] [Abstract][Full Text] [Related]
5. Cardiac output monitoring: comparison of a new arterial pressure waveform analysis to the bolus thermodilution technique in patients undergoing off-pump coronary artery bypass surgery.
Mehta Y; Chand RK; Sawhney R; Bhise M; Singh A; Trehan N
J Cardiothorac Vasc Anesth; 2008 Jun; 22(3):394-9. PubMed ID: 18503927
[TBL] [Abstract][Full Text] [Related]
6. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform.
Lorsomradee S; Lorsomradee S; Cromheecke S; De Hert SG
J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):636-43. PubMed ID: 17905266
[TBL] [Abstract][Full Text] [Related]
7. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis.
Biais M; Nouette-Gaulain K; Cottenceau V; Vallet A; Cochard JF; Revel P; Sztark F
Anesth Analg; 2008 May; 106(5):1480-6, table of contents. PubMed ID: 18420863
[TBL] [Abstract][Full Text] [Related]
8. Comparison of cardiac output determined by arterial pulse pressure waveform analysis method (FloTrac/Vigileo) versus lithium dilution method in anesthetized dogs.
Valverde A; Gianotti G; Rioja E; Hathway A
J Vet Emerg Crit Care (San Antonio); 2011 Aug; 21(4):328-34. PubMed ID: 21827590
[TBL] [Abstract][Full Text] [Related]
9. Comparison of FloTrac cardiac output monitoring system in patients undergoing coronary artery bypass grafting with pulmonary artery cardiac output measurements.
Cannesson M; Attof Y; Rosamel P; Joseph P; Bastien O; Lehot JJ
Eur J Anaesthesiol; 2007 Oct; 24(10):832-9. PubMed ID: 17666154
[TBL] [Abstract][Full Text] [Related]
10. Transient hemodynamic change and accuracy of arterial blood pressure-based cardiac output.
Kotake Y; Yamada T; Nagata H; Takeda J; Shimizu H
Anesth Analg; 2011 Aug; 113(2):272-4. PubMed ID: 21467564
[TBL] [Abstract][Full Text] [Related]
11. Edwards FloTrac sensor and Vigileo monitor: easy, accurate, reliable cardiac output assessment using the arterial pulse wave.
Manecke GR
Expert Rev Med Devices; 2005 Sep; 2(5):523-7. PubMed ID: 16293062
[TBL] [Abstract][Full Text] [Related]
12. [Clinical evaluation of intraoperative cardiac output measurement by a new arterial pressure waveform analysis method( FloTrac/Vigileo) in open heart surgery].
Furukawa H; Ohkado A; Nagashima M; Ohsawa H; Ichikawa S
Kyobu Geka; 2013 Aug; 66(9):775-83. PubMed ID: 23917227
[TBL] [Abstract][Full Text] [Related]
13. Accuracy and Trending Ability of the Fourth-Generation FloTrac/Vigileo System in Patients With Low Cardiac Index.
Hattori K; Maeda T; Masubuchi T; Yoshikawa A; Ebuchi K; Morishima K; Kamei M; Yoshitani K; Ohnishi Y
J Cardiothorac Vasc Anesth; 2017 Feb; 31(1):99-104. PubMed ID: 27612931
[TBL] [Abstract][Full Text] [Related]
14. Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery.
Breukers RM; Sepehrkhouy S; Spiegelenberg SR; Groeneveld AB
J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):632-5. PubMed ID: 17905265
[TBL] [Abstract][Full Text] [Related]
15. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients.
Cannesson M; Musard H; Desebbe O; Boucau C; Simon R; Hénaine R; Lehot JJ
Anesth Analg; 2009 Feb; 108(2):513-7. PubMed ID: 19151280
[TBL] [Abstract][Full Text] [Related]
16. The Vigileo-FloTracâ„¢ system: arterial waveform analysis for measuring cardiac output and predicting fluid responsiveness: a clinical review.
Suehiro K; Tanaka K; Matsuura T; Funao T; Yamada T; Mori T; Nishikawa K
J Cardiothorac Vasc Anesth; 2014 Oct; 28(5):1361-74. PubMed ID: 25027098
[No Abstract] [Full Text] [Related]
17. [Arterial pressure-based cardiac output monitoring: 1. FloTrac sensor and SVV].
Seo K
Masui; 2009 Jul; 58(7):838-47. PubMed ID: 19618824
[TBL] [Abstract][Full Text] [Related]
18. FloTrac for monitoring arterial pressure and cardiac output during phaeochromocytoma surgery.
Collange O; Xavier L; Kuntzman H; Calon B; Schaeffer R; Pottecher T; Diemunsch P; Pessaux P
Eur J Anaesthesiol; 2008 Sep; 25(9):779-80. PubMed ID: 18477419
[No Abstract] [Full Text] [Related]
19. Evaluation of the FloTrac uncalibrated continuous cardiac output system for perioperative hemodynamic monitoring after subarachnoid hemorrhage.
Mutoh T; Ishikawa T; Nishino K; Yasui N
J Neurosurg Anesthesiol; 2009 Jul; 21(3):218-25. PubMed ID: 19542999
[TBL] [Abstract][Full Text] [Related]
20. [Reliability of a less-invasive cardiac output monitor in the perioperative period of a patient with severe dilated cardiomyopathy].
Sotomi Y; Nishiyama C; Shimizu T; Kita T; Maki N; Sasaki S
Masui; 2011 Feb; 60(2):203-7. PubMed ID: 21384657
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]