299 related articles for article (PubMed ID: 19465832)
1. Dual-source CT in heart transplant recipients: quantification of global left ventricular function and mass.
Bastarrika G; Arraiza M; De Cecco CN; Broncano J; Mastrobuoni S; Ubilla M; Pueyo JC; Rábago G
J Thorac Imaging; 2009 May; 24(2):103-9. PubMed ID: 19465832
[TBL] [Abstract][Full Text] [Related]
2. [Assessment of global and regional left ventricular function with a 16-slice spiral-CT using two different software tools for quantitative functional analysis and qualitative evaluation of wall motion changes in comparison with magnetic resonance imaging].
Koch K; Oellig F; Kunz P; Bender P; Oberholzer K; Mildenberger P; Hake U; Kreitner KF; Thelen M
Rofo; 2004 Dec; 176(12):1786-93. PubMed ID: 15573290
[TBL] [Abstract][Full Text] [Related]
3. [Quantification of left ventricular function and mass in dual-source CT (DSCT).].
Arraiza M; Bastarrika G; Zudaire B; Pueyo J; Villanueva A
Radiologia; 2009; 51(2):148-55. PubMed ID: 19286237
[TBL] [Abstract][Full Text] [Related]
4. Quantification of left ventricular function and mass in cardiac Dual-Source CT (DSCT) exams: comparison of manual and semiautomatic segmentation algorithms.
Bastarrika G; Arraiza M; Pueyo JC; Herraiz MJ; Zudaire B; Villanueva A
Eur Radiol; 2008 May; 18(5):939-46. PubMed ID: 18292999
[TBL] [Abstract][Full Text] [Related]
5. Analysis of cardiac dimensions, mass and function in heart transplant recipients using 64-slice multi-detector computed tomography.
Ferencik M; Gregory SA; Butler J; Achenbach S; Yeh RW; Hoffmann U; Inglessis I; Cury RC; Nieman K; McNulty IA; Healy JA; Brady TJ; Semigran MJ; Jang IK
J Heart Lung Transplant; 2007 May; 26(5):478-84. PubMed ID: 17449417
[TBL] [Abstract][Full Text] [Related]
6. MR evaluation of left ventricular volumes and function: threshold-based 3D segmentation versus short-axis planimetry.
Nassenstein K; de Greiff A; Hunold P
Invest Radiol; 2009 Oct; 44(10):635-40. PubMed ID: 19724238
[TBL] [Abstract][Full Text] [Related]
7. Development and evaluation of a semiautomatic segmentation method for the estimation of LV parameters on cine MR images.
Mazonakis M; Grinias E; Pagonidis K; Tziritas G; Damilakis J
Phys Med Biol; 2010 Feb; 55(4):1127-40. PubMed ID: 20107252
[TBL] [Abstract][Full Text] [Related]
8. Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience.
Juergens KU; Grude M; Maintz D; Fallenberg EM; Wichter T; Heindel W; Fischbach R
Radiology; 2004 Feb; 230(2):403-10. PubMed ID: 14668428
[TBL] [Abstract][Full Text] [Related]
9. Accuracy of different reconstruction intervals to quantify left ventricular function and mass in cardiac computed tomography examinations.
Arraiza M; Azcárate PM; Arias J; de Cecco CN; Pueyo JC; Rábago G; Bastarrika G
Radiologia; 2012; 54(5):432-41. PubMed ID: 21920566
[TBL] [Abstract][Full Text] [Related]
10. Comparison of manual, semi- and fully automated heart segmentation for assessing global left ventricular function in multidetector computed tomography.
Plumhans C; Keil S; Ocklenburg C; Mühlenbruch G; Behrendt FF; Günther RW; Mahnken AH
Invest Radiol; 2009 Aug; 44(8):476-82. PubMed ID: 19561515
[TBL] [Abstract][Full Text] [Related]
11. Quantification of left and right ventricular function and myocardial mass: comparison of low-radiation dose 2nd generation dual-source CT and cardiac MRI.
Takx RA; Moscariello A; Schoepf UJ; Barraza JM; Nance JW; Bastarrika G; Das M; Meyer M; Wildberger JE; Schoenberg SO; Fink C; Henzler T
Eur J Radiol; 2012 Apr; 81(4):e598-604. PubMed ID: 21831552
[TBL] [Abstract][Full Text] [Related]
12. Reproducibility of left and right ventricular mass measurements with cardiac CT.
Schwarz F; Takx R; Schoepf UJ; Lee YS; Ruzsics B; Gassner EM; Chiaramida S; Henzler T
J Cardiovasc Comput Tomogr; 2011; 5(5):317-24. PubMed ID: 21875827
[TBL] [Abstract][Full Text] [Related]
13. Segmentation of cardiac cine MR images of left and right ventricles: interactive semiautomated methods and manual contouring by two readers with different education and experience.
Sardanelli F; Quarenghi M; Di Leo G; Boccaccini L; Schiavi A
J Magn Reson Imaging; 2008 Apr; 27(4):785-92. PubMed ID: 18302202
[TBL] [Abstract][Full Text] [Related]
14. Automated threshold-based 3D segmentation versus short-axis planimetry for assessment of global left ventricular function with dual-source MDCT.
Juergens KU; Seifarth H; Range F; Wienbeck S; Wenker M; Heindel W; Fischbach R
AJR Am J Roentgenol; 2008 Feb; 190(2):308-14. PubMed ID: 18212214
[TBL] [Abstract][Full Text] [Related]
15. Comparison of a multi-breath-hold and a single breath-hold cine imaging approach for 4D guide-point modeling of the left ventricle.
Heilmaier C; Schlosser T; Bruder O; Nassenstein K
Rofo; 2010 Sep; 182(9):780-7. PubMed ID: 20563959
[TBL] [Abstract][Full Text] [Related]
16. Influence of heart rate and temporal resolution on left-ventricular volumes in cardiac multislice spiral computed tomography: a phantom study.
Mahnken AH; Hohl C; Suess C; Bruder H; Mühlenbruch G; Das M; Günther RW; Wildberger JE
Invest Radiol; 2006 May; 41(5):429-35. PubMed ID: 16625105
[TBL] [Abstract][Full Text] [Related]
17. [Quantification of cardiac function with multislice spiral CT using retrospective EKG-gating: comparison with MRI].
Mahnken AH; Spüntrup E; Wildberger JE; Heuschmid M; Niethammer M; Sinha AM; Flohr T; Bücker A; Günther RW
Rofo; 2003 Jan; 175(1):83-8. PubMed ID: 12525986
[TBL] [Abstract][Full Text] [Related]
18. Left ventricular and left atrial dimensions and volumes: comparison between dual-source CT and echocardiography.
Stolzmann P; Scheffel H; Trindade PT; Plass AR; Husmann L; Leschka S; Genoni M; Marincek B; Kaufmann PA; Alkadhi H
Invest Radiol; 2008 May; 43(5):284-9. PubMed ID: 18424948
[TBL] [Abstract][Full Text] [Related]
19. Rapid and accurate left ventricular chamber quantification using a novel CMR segmentation algorithm: a clinical validation study.
Codella NC; Cham MD; Wong R; Chu C; Min JK; Prince MR; Wang Y; Weinsaft JW
J Magn Reson Imaging; 2010 Apr; 31(4):845-53. PubMed ID: 20373428
[TBL] [Abstract][Full Text] [Related]
20. Semiautomatic detection of left ventricular contours in contrast-enhanced echocardiographic images: Comparison with magnetic resonance imaging.
Morales MA; Positano V; Lombardi M; Rodriguez O; Passera M; Rovai D
J Am Soc Echocardiogr; 2004 Aug; 17(8):876-82. PubMed ID: 15282493
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]