BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

151 related articles for article (PubMed ID: 19467804)

  • 1. Effectiveness of educational intervention on the congruence of prostate and rectal contouring as compared with a gold standard in three-dimensional radiotherapy for prostate.
    Szumacher E; Harnett N; Warner S; Kelly V; Danjoux C; Barker R; Woo M; Mah K; Ackerman I; Dubrowski A; Rose S; Crook J
    Int J Radiat Oncol Biol Phys; 2010 Feb; 76(2):379-85. PubMed ID: 19467804
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI Sequences.
    Dowling JA; Sun J; Pichler P; Rivest-Hénault D; Ghose S; Richardson H; Wratten C; Martin J; Arm J; Best L; Chandra SS; Fripp J; Menk FW; Greer PB
    Int J Radiat Oncol Biol Phys; 2015 Dec; 93(5):1144-53. PubMed ID: 26581150
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of multiorgan finite element-based prostate deformation model enabling registration of endorectal coil magnetic resonance imaging for radiotherapy planning.
    Hensel JM; Ménard C; Chung PW; Milosevic MF; Kirilova A; Moseley JL; Haider MA; Brock KK
    Int J Radiat Oncol Biol Phys; 2007 Aug; 68(5):1522-8. PubMed ID: 17674983
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Anatomic variations due to radical prostatectomy. Impact on target volume definition and dose-volume parameters of rectum and bladder.
    Sanguineti G; Castellone P; Foppiano F; Franzone P; Marcenaro M; Tognoni P; Bolognesi A; Ceresoli GL; Fiorino C
    Strahlenther Onkol; 2004 Sep; 180(9):563-72. PubMed ID: 15378187
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Radiographic and anatomic basis for prostate contouring errors and methods to improve prostate contouring accuracy.
    McLaughlin PW; Evans C; Feng M; Narayana V
    Int J Radiat Oncol Biol Phys; 2010 Feb; 76(2):369-78. PubMed ID: 19515511
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Magnetic resonance imaging for prostate bed radiotherapy planning: An inter- and intra-observer variability study.
    Barkati M; Simard D; Taussky D; Delouya G
    J Med Imaging Radiat Oncol; 2016 Apr; 60(2):255-9. PubMed ID: 26568515
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prostate cancer: contouring target and organs at risk by kilovoltage and megavoltage CT and MRI in patients with and without hip prostheses.
    Falcinelli L; Palumbo I; Radicchia V; Arcidiacono F; Lancellotta V; Montesi G; Matrone F; Zucchetti C; Marcantonini M; Bini V; Aristei C
    Br J Radiol; 2015; 88(1056):20150509. PubMed ID: 26462970
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Changes in the pelvic anatomy after an IMRT treatment fraction of prostate cancer.
    de Crevoisier R; Melancon AD; Kuban DA; Lee AK; Cheung RM; Tucker SL; Kudchadker RJ; Newhauser WD; Zhang L; Mohan R; Dong L
    Int J Radiat Oncol Biol Phys; 2007 Aug; 68(5):1529-36. PubMed ID: 17544595
    [TBL] [Abstract][Full Text] [Related]  

  • 9. ESTRO ACROP consensus guideline on CT- and MRI-based target volume delineation for primary radiation therapy of localized prostate cancer.
    Salembier C; Villeirs G; De Bari B; Hoskin P; Pieters BR; Van Vulpen M; Khoo V; Henry A; Bossi A; De Meerleer G; Fonteyne V
    Radiother Oncol; 2018 Apr; 127(1):49-61. PubMed ID: 29496279
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Increased risk of biochemical and local failure in patients with distended rectum on the planning CT for prostate cancer radiotherapy.
    de Crevoisier R; Tucker SL; Dong L; Mohan R; Cheung R; Cox JD; Kuban DA
    Int J Radiat Oncol Biol Phys; 2005 Jul; 62(4):965-73. PubMed ID: 15989996
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prostate volumes and organ movement defined by serial computerized tomographic scans during three-dimensional conformal radiotherapy.
    Roach M; Faillace-Akazawa P; Malfatti C
    Radiat Oncol Investig; 1997; 5(4):187-94. PubMed ID: 9327498
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer.
    Debois M; Oyen R; Maes F; Verswijvel G; Gatti G; Bosmans H; Feron M; Bellon E; Kutcher G; Van Poppel H; Vanuytsel L
    Int J Radiat Oncol Biol Phys; 1999 Nov; 45(4):857-65. PubMed ID: 10571190
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Reduction of prostate motion by removal of gas in rectum during radiotherapy.
    Ogino I; Uemura H; Inoue T; Kubota Y; Nomura K; Okamoto N
    Int J Radiat Oncol Biol Phys; 2008 Oct; 72(2):456-66. PubMed ID: 18374517
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Do differences in target volume definition in prostate cancer lead to clinically relevant differences in normal tissue toxicity?
    Livsey JE; Wylie JP; Swindell R; Khoo VS; Cowan RA; Logue JP
    Int J Radiat Oncol Biol Phys; 2004 Nov; 60(4):1076-81. PubMed ID: 15519777
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prostate seed implantation using 3D-computer assisted intraoperative planning vs. a standard look-up nomogram: Improved target conformality with reduction in urethral and rectal wall dose.
    Raben A; Chen H; Grebler A; Geltzeiler J; Geltzeiler M; Keselman I; Litvin S; Sim S; Hanlon A; Yang J
    Int J Radiat Oncol Biol Phys; 2004 Dec; 60(5):1631-8. PubMed ID: 15590195
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Emptying the rectum before treatment delivery limits the variations of rectal dose - volume parameters during 3DCRT of prostate cancer.
    Stasi M; Munoz F; Fiorino C; Pasquino M; Baiotto B; Marini P; Malinverni G; Valdagni R; Gabriele P
    Radiother Oncol; 2006 Sep; 80(3):363-70. PubMed ID: 16959344
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Automatic segmentation of pelvic structures from magnetic resonance images for prostate cancer radiotherapy.
    Pasquier D; Lacornerie T; Vermandel M; Rousseau J; Lartigau E; Betrouni N
    Int J Radiat Oncol Biol Phys; 2007 Jun; 68(2):592-600. PubMed ID: 17498571
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dose-volume differences for computed tomography and magnetic resonance imaging segmentation and planning for proton prostate cancer therapy.
    Yeung AR; Vargas CE; Falchook A; Louis D; Olivier K; Keole S; Yeung D; Mendenhall NP; Li Z
    Int J Radiat Oncol Biol Phys; 2008 Dec; 72(5):1426-33. PubMed ID: 18762391
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Analysis of interfraction prostate motion using megavoltage cone beam computed tomography.
    Bylund KC; Bayouth JE; Smith MC; Hass AC; Bhatia SK; Buatti JM
    Int J Radiat Oncol Biol Phys; 2008 Nov; 72(3):949-56. PubMed ID: 19014783
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Segmenting the prostate and rectum in CT imagery using anatomical constraints.
    Chen S; Lovelock DM; Radke RJ
    Med Image Anal; 2011 Feb; 15(1):1-11. PubMed ID: 20634121
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.