These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

130 related articles for article (PubMed ID: 1947083)

  • 1. Paranasal sinuses: low-dose CT.
    Marmolya G; Wiesen EJ; Yagan R; Haria CD; Shah AC
    Radiology; 1991 Dec; 181(3):689-91. PubMed ID: 1947083
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Radiation dose to the lens of eye and thyroid gland in paranasal sinus multislice CT.
    Zammit-Maempel I; Chadwick CL; Willis SP
    Br J Radiol; 2003 Jun; 76(906):418-20. PubMed ID: 12814929
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Tailored low dose three-dimensional CT of paranasal sinuses.
    Damilakis J; Prassopoulos P; Mazonakis M; Bizakis J; Papadaki E; Gourtsoyiannis N
    Clin Imaging; 1998; 22(4):235-9. PubMed ID: 9699043
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Multislice spiral CT of the paranasal sinuses: first experiences using various parameters of radiation dosage].
    Dammann F; Bode A; Heuschmid M; Kopp A; Georg C; Pereira PL; Claussen CD
    Rofo; 2000 Aug; 172(8):701-6. PubMed ID: 11013612
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Low-dose computed tomography of the paranasal sinuses: radiation doses and reliability analysis.
    Abul-Kasim K; Strömbeck A; Sahlstrand-Johnson P
    Am J Otolaryngol; 2011; 32(1):47-51. PubMed ID: 20015806
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Ultra-low dose dual-source high-pitch computed tomography of the paranasal sinus: diagnostic sensitivity and radiation dose.
    Schulz B; Potente S; Zangos S; Friedrichs I; Bauer RW; Kerl M; Vogl TJ; Mack MM
    Acta Radiol; 2012 May; 53(4):435-40. PubMed ID: 22517983
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of radiographic techniques on the low-contrast detail detectability performance of digital radiography systems.
    Alsleem H; U P; Mong KS; Davidson R
    Radiol Technol; 2014; 85(6):614-22. PubMed ID: 25002641
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Radiation dose to the lens from coronal CT scanning of the sinuses.
    MacLennan AC
    Clin Radiol; 1995 Apr; 50(4):265-7. PubMed ID: 7729127
    [TBL] [Abstract][Full Text] [Related]  

  • 9. CT scanning of the paranasal sinuses--the effect of reducing mAs.
    Kearney SE; Jones P; Meakin K; Garvey CJ
    Br J Radiol; 1997 Oct; 70(838):1071-4. PubMed ID: 9404216
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Value of secondary coronal reconstructions in computed tomography of the paranasal sinuses].
    Lang S; Jäger L; Grevers G
    Laryngorhinootologie; 2002 Jun; 81(6):418-21. PubMed ID: 12063628
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Radiation dose to the lenses in CT of the paranasal sinuses.
    Moulin G; Chagnaud C; Waultier S; Le Brigand B; Espagnan M; Dessi P; Bartoli JM; Châtenet P; Botti G
    Neuroradiology; 1996 May; 38 Suppl 1():S127-9. PubMed ID: 8811699
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Low-dose CT of the paranasal sinuses with eye lens protection: effect on image quality and radiation dose.
    Hein E; Rogalla P; Klingebiel R; Hamm B
    Eur Radiol; 2002 Jul; 12(7):1693-6. PubMed ID: 12111059
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Dental flat panel conebeam CT in the evaluation of patients with inflammatory sinonasal disease: Diagnostic efficacy and radiation dose savings.
    Leiva-Salinas C; Flors L; Gras P; Más-Estellés F; Lemercier P; Patrie JT; Wintermark M; Martí-Bonmatí L
    AJNR Am J Neuroradiol; 2014; 35(11):2052-7. PubMed ID: 24970545
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Normal CT anatomy of the paranasal sinuses.
    Schatz CJ; Becker TS
    Radiol Clin North Am; 1984 Mar; 22(1):107-18. PubMed ID: 6709864
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiation dose to the eye lens from coronal CT scanning of the sinuses.
    Spencer DH
    Clin Radiol; 1996 Sep; 51(9):666. PubMed ID: 8810705
    [No Abstract]   [Full Text] [Related]  

  • 16. Radiation dose to the eyes and parotids during CT of the sinuses.
    Bassim MK; Ebert CS; Sit RC; Senior BA
    Otolaryngol Head Neck Surg; 2005 Oct; 133(4):531-3. PubMed ID: 16213924
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Low-dose CT and inflammatory disease of the paranasal sinuses.
    Duvoisin B; Landry M; Chapuis L; Krayenbuhl M; Schnyder P
    Neuroradiology; 1991; 33(5):403-6. PubMed ID: 1749469
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Low-Dose Noncontrast Examination of the Paranasal Sinuses Using Volumetric Computed Tomography.
    Pirimoglu B; Sade R; Sakat MS; Ogul H; Levent A; Kantarci M
    J Comput Assist Tomogr; 2018; 42(3):482-486. PubMed ID: 29287024
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Radiation exposure in paranasal sinus imaging.
    Sillers MJ; Kuhn FA; Vickery CL
    Otolaryngol Head Neck Surg; 1995 Feb; 112(2):248-51. PubMed ID: 7838547
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Modern imaging of paranasal sinuses and the role of limited sinus computerized tomography; considerations of time, cost and radiation.
    Mafee MF
    Ear Nose Throat J; 1994 Aug; 73(8):532-4, 536-8, 540-2 passim. PubMed ID: 7956849
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.