These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 19472055)

  • 1. Hemodynamically driven stent strut design.
    Jiménez JM; Davies PF
    Ann Biomed Eng; 2009 Aug; 37(8):1483-94. PubMed ID: 19472055
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hemodynamic Performance of a New Punched Stent Strut: A Numerical Study.
    Xue Y; Liu X; Sun A; Zhang P; Fan Y; Deng X
    Artif Organs; 2016 Jul; 40(7):669-77. PubMed ID: 26581476
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Local hemodynamic analysis after coronary stent implantation based on Euler-Lagrange method.
    Wang Y; Zhan J; Bian W; Tang X; Zeng M
    J Biol Phys; 2021 Jun; 47(2):143-170. PubMed ID: 34046777
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions.
    He Y; Duraiswamy N; Frank AO; Moore JE
    J Biomech Eng; 2005 Aug; 127(4):637-47. PubMed ID: 16121534
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the effect of stent strut profile on shear stress distribution using statistical moments.
    Mejia J; Ruzzeh B; Mongrain R; Leask R; Bertrand OF
    Biomed Eng Online; 2009 Apr; 8():8. PubMed ID: 19405976
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Three-dimensional computational fluid dynamics modeling of alterations in coronary wall shear stress produced by stent implantation.
    LaDisa JF; Guler I; Olson LE; Hettrick DA; Kersten JR; Warltier DC; Pagel PS
    Ann Biomed Eng; 2003 Sep; 31(8):972-80. PubMed ID: 12918912
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Localized Hemodynamics of Drug-Eluting Stents Are Not Improved by the Presence of Magnetic Struts.
    Vijayaratnam PR; Barber TJ; Reizes JA
    J Biomech Eng; 2017 Jan; 139(1):. PubMed ID: 27893059
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Macro- and microscale variables regulate stent haemodynamics, fibrin deposition and thrombomodulin expression.
    Jiménez JM; Prasad V; Yu MD; Kampmeyer CP; Kaakour AH; Wang PJ; Maloney SF; Wright N; Johnston I; Jiang YZ; Davies PF
    J R Soc Interface; 2014 May; 11(94):20131079. PubMed ID: 24554575
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A multi-objective optimization of stent geometries.
    Gharleghi R; Wright H; Luvio V; Jepson N; Luo Z; Senthurnathan A; Babaei B; Prusty BG; Ray T; Beier S
    J Biomech; 2021 Aug; 125():110575. PubMed ID: 34186293
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening.
    LaDisa JF; Olson LE; Hettrick DA; Warltier DC; Kersten JR; Pagel PS
    Biomed Eng Online; 2005 Oct; 4():59. PubMed ID: 16250918
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Comparison of near-wall hemodynamic parameters in stented artery models.
    Duraiswamy N; Schoephoerster RT; Moore JE
    J Biomech Eng; 2009 Jun; 131(6):061006. PubMed ID: 19449960
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Stent strut streamlining and thickness reduction promote endothelialization.
    Nguyen DT; Smith AF; Jiménez JM
    J R Soc Interface; 2021 Aug; 18(181):20210023. PubMed ID: 34404229
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The influence of strut-connectors in stented vessels: a comparison of pulsatile flow through five coronary stents.
    Pant S; Bressloff NW; Forrester AI; Curzen N
    Ann Biomed Eng; 2010 May; 38(5):1893-907. PubMed ID: 20177782
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Haemodynamic effects of incomplete stent apposition in curved coronary arteries.
    Chen WX; Poon EKW; Thondapu V; Hutchins N; Barlis P; Ooi A
    J Biomech; 2017 Oct; 63():164-173. PubMed ID: 29032800
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of stent design parameters on normal artery wall mechanics.
    Bedoya J; Meyer CA; Timmins LH; Moreno MR; Moore JE
    J Biomech Eng; 2006 Oct; 128(5):757-65. PubMed ID: 16995763
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simulation of the microscopic process during initiation of stent thrombosis.
    Chesnutt JK; Han HC
    Comput Biol Med; 2015 Jan; 56():182-91. PubMed ID: 25437232
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of stent effect and thrombosis generation with different blood rheology on an intracranial aneurysm by the Lattice Boltzmann method.
    Mezali F; Benmamar S; Naima K; Ameur H; Rafik O
    Comput Methods Programs Biomed; 2022 Jun; 219():106757. PubMed ID: 35338884
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Hemodynamics in Idealized Stented Coronary Arteries: Important Stent Design Considerations.
    Beier S; Ormiston J; Webster M; Cater J; Norris S; Medrano-Gracia P; Young A; Cowan B
    Ann Biomed Eng; 2016 Feb; 44(2):315-29. PubMed ID: 26178872
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Developing pulsatile flow in a deployed coronary stent.
    Rajamohan D; Banerjee RK; Back LH; Ibrahim AA; Jog MA
    J Biomech Eng; 2006 Jun; 128(3):347-59. PubMed ID: 16706584
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Compound ex vivo and in silico method for hemodynamic analysis of stented arteries.
    Rikhtegar F; Pacheco F; Wyss C; Stok KS; Ge H; Choo RJ; Ferrari A; Poulikakos D; Müller R; Kurtcuoglu V
    PLoS One; 2013; 8(3):e58147. PubMed ID: 23516442
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.